Developing accurate methods for the assessment of therapeutic protein release from polymer drug delivery systems (microcapsules, microspheres, nanoparticles, 3D-printed systems) is of paramount importance for new formulation development. The most straightforward method for protein release assessment is spectrophotometric analysis of the release medium surrounding the formulation. However, direct spectrophotometric analysis is inapplicable to formulations releasing interfering compounds (coencapsulated drugs, additives) absorbing light in the same spectrum as proteins. Conventional protein release assays also require frequent release medium sampling and replacement, which reduces their accuracy. We propose a one-step method to assess protein release from core/shell microcapsules eliminating the need for sampling and allowing selective real-time protein quantitation in the release medium. To prevent spectral interferences, released protein is differentiated from interfering compounds by employing a colorimetric protein assay reagent, forming a colour complex selectively with the protein, as the release medium. To eliminate sampling, we employed a continuous flow closed loop set-up, where the release medium is constantly circulating between microcapsule-containing tank and spectrophotometer. A series of colorimetric protein assay reagents (bromocresol green, tetrabromophenol blue, eosin B, eosin Y, biuret) were evaluated in terms of their applicability as the release medium in described system. Only biuret reagent was found compatible with proposed method due to formation of color complex stable over extended period of time and low adsorption to microcapsules. Presented method allowed effective evaluation of albumin release from alginate-polyethersulfone microcapsules with accuracy equal to conventional ‘sample and separate’ technique. Albumin release followed first-order kinetics with plateau reached after 19 h.
PL
W pracy scharakteryzowano wpływ wirującego pola magnetycznego na stopień zatrzymania gazu w cieczy (hold-up) oraz objętościowy współczynnik wnikania masy kLa w nowej konstrukcji reaktora airlift. W ramach przeprowadzonych badań przeanalizowano wpływ prędkości liniowej strumienia gazu oraz częstotliwości i miejsca ekspozycji WPM na testowane wielkości. Uzyskane wyniki pozwoliły na stwierdzenie, że zastosowanie WPM pozytywnie wpływa na intensyfikację procesu wymiany masy w reaktorze airlift.
EN
The main aim of this paper is to present the effect of rotating magnetic field (RMF) on gas hold-up and volumetric mass transfer coefficient kLa in a new construction of airlift reactor. Moreover, the influence of superficial gas velocity and frequency and RMF exposure location on tested parameters were analyzed. It was concluded that the use of RMF positively influences the mass transfer process intensification in the airlift reactor.
PL
Przedstawiono sposób określania współczynnika wnikania masy w cieczy podczas destylacji roztworu izopropanol-woda w wyparce cienkowarstewkowej wyposażonej w łopatki rozcierające ciecz po ogrzewanej powierzchni. Wartości współczynników wnikania masy uzyskano dwiema metodami. W pierwszej wykorzystano dane doświadczalne destylacji cienkowarstewkowej, a w drugiej metodzie - dane doświadczalne wymiany ciepła podczas destylacji. Wartości współczynników wnikania masy w cieczy wyznaczone za pomocą obu metod były zbliżone.
EN
The procedure used for the determination o f individual mass transfer coefficients in the liquid phase during distillation of isopropyl alcohol-water solution in a thin-layer evaporator is presented in the paper. The values o f individual mass transfer coefficients were obtained by two methods. In the first method the distillation data were used. In the second one the heat transfer experimental data obtained during distillation were applied. Both methods gave similar results.
PL
W artykule przedstawiono wyniki badań doświadczalnych współczynnika wnikania masy w procesie mieszania cieczy mieszadłem turbinowym Rushtona oraz mieszadłem śmigłowym z jednoczesnym napowietrzaniem. Wykazano, że mieszadło śmigłowe nadaje się bardziej do rozprowadzania tlenu przy niższych wartościach częstości obrotowych mieszadła. Turbina Rushtona lepiej rozprowadzała tlen przy większych wartościach częstości obrotów.
EN
The paper presents results of experimental studies on the volumetric mass transfer coefficient for two types of impellers (Rushton turbine and propeller stirrer) in the mixing process with the aeration. It has been shown that propeller stirrer is more suitable for a distribution of oxygen at lower rotation speeds. It appeared that the Rushton turbine distributes oxygen better at the higher rotation of speeds.
PL
W pracy przedstawiono uzyskane metodą elektrochemiczną rozkłady lokalnych wartości współczynnika wnikania masy w mieszalniku z samozasysającym mieszadłem tarczowym. Rozkłady te porównano z wartościami obliczonymi z dwu modeli procesu wnikania masy. W obliczeniach wykorzystano informacje o prędkościach i rozmiarach pęcherzyków uzyskane metodą PIV. Okazało się, że model Frösslinga daje lepszą zgodność od modelu Higbie’go, ale i on wymaga korekty wartości stałej. Dalsza analiza wykazała też, że dane uzyskane metodą elektrochemiczną są obarczone trudnym do oszacowania błędem.
EN
Distribution of local values of mass transfer coefficient obtained by the electrochemical method in a tank with the self-aspirating disk impeller is presented in the paper. These distributions were compared with values calculated using two models of mass transfer process. Information about velocities and bubble sizes obtained from the PIV method were used in calculations. It turned out that Frosslings model gives better compatibility than Higbie s model, however first one required the correction of constant values, too. Further analysis also showed that data obtained from the electrochemical method are subject to error which is difficult to estimate.
EN
Electrochemical method of heat exchange coefficient determination is described. It is heat/mass analogy based method that can be helpful in heat exchangers design process.
7
Content available remote Współczynnik wnikania masy w wypełnieniu chłodni wentylatorowej
EN
The paper presents derivation of a mass transfer coefficient formula. The derivation was based on dimensional analysis and experimental research results.
EN
Measurement results of coefficients kL. and kLa are discussed in the paper. Based on local values, the effective mass transfer area in the whole tank was determined. For the height equal to the impeller position, a non-typical decrease of the effective mass transfer area was observed. This phenomenon confirmed that the entire real surface of gas bubbles did not take part in the mass transfer.
PL
Piecie indukcyjne należą do tych urządzeń, które od lat wykorzystywane są do wytopu różnych gatunków stali. W procesach występuje wiele zjawisk fizykochemicznych, zachodzących w układzie ciekła faza metaliczna - faza gazowa. Wspomnieć tu należy np. o odparowaniu lotnych składników kąpieli lub desorbcji gazów rozpuszczonych w ciekłym metalu. Z kinetycznego punktu widzenia o szybkości tych zjawisk decydują m. in. zjawiska transportu masy w obu fazach. Charakter ruchu i jego intensywność, wywołany działaniem sił pola elektromagnetycznego, są funkcjami wielu zmiennych, takich jak geometria pieca, gęstość wydzielonej mocy, częstotliwość, a także usytuowanie wzbudnika względem metalicznego wsadu. W prezentowanym artykule przedstawiono metodę wyznaczania wartości współczynnika wnikania masy w ciekłej fazie mieszanej indukcyjnie, z wykorzystaniem modeli turbulentnych Lamonta i Scotta, a także Kolmogorova. Wykorzystano do tego model numeryczny, pozwalający na określenie pola sił elektromagnetycznych i pola turbulencji. Dzięki temu wyznaczono wartości sił Lorentza, a następnie określono prędkość przypowierzchniową metalu. Obliczenia wykonano dla próżniowego pieca indukcyjnego IS5/III firmy Leybold Heraeus. Znajomość wartości współczynnika wnikania masy w ciekłej fazie metalicznej mieszanej indukcyjnie może pozwolić na opis zjawisk zachodzących w wielu procesach metalurgicznych, m. in. w procesach wytopu i obróbki próżniowej stali.
EN
The paper presents the method of determination of mass transfer coefficient in elektromagnetic stirred liquid phase based on Lamont, Scott and Kolmogorov turbulent models. For this purpose the numerical model allowing the determination of electromagnetic force and turbulent field was utilized. As result the values of Lorentz forces and metal surface velocity have been determined. Calculations were made for IS5/III Leybold Heraeus induction furnace.
PL
Celem niniejszej pracy jest określenie (na podstawie wartości współczynnika wnikania masy przypadającego na jednostkę mocy mieszania, kL/PG) optymalnych warunków pracy samozasysającego mieszadła tarczowego. Metodą fotograficzną określono w pracy wymiary pęcherzyków gazu oraz powierzchnię międzyfazową układu i na podstawie pomiarów objętościowego współczynnika wnikania masy przedstawiono efektywność pracy mieszadła. Dla badanego typu mieszadła wartości współczynników wnikania masy ustalają się począwszy od wartości Fr’≈0,4. W przypadku roztworu elektrolitu (NaCl) efektywność wnikania masy jest nieco mniejsza niż w przypadku cieczy - nieelektolitów (woda, roztwór rokrysolu).
EN
The aim of this study is to determine optimum operating conditions for a self-aspirating disk impeller on the basis of mass transfer coefficient per unit of mixing power, kL/PG. Gas bubble sizes and interfacial area of the system were calculated using a photographic method and the impeller operation efficiency was presented on the basis of measurements of the volumetric mass transfer coefficient. For the tested impeller, the values of mass transfer coefficient are settled starting from Fr'≈0.4. In the case of electrolyte solution (NaCl), the mass transfer efficiency is slightly lower than in the case of liquids being non-electrolytes, e.g. water and rokrysol solution.
PL
W pracy zaproponowano zmodyfikowane stanowisko do pomiarów lokalnych wartości objętościowego współczynnika wnikania masy kLa metodą dynamiczną. Przeanalizowano poszczególne elementy stanowiska pod względem identyfikacji parametrów wpływających na jakość pomiarów. Przeprowadzono analizę współczynnika kja dla układu woda - powietrze przy zastosowaniu tarczowego mieszadła samozasysającego o średnicy dm = 125 mm.
EN
A modified set-up for measuring local values of the volumetric mass transfer coefficient, ki.a, by a dynamic method was proposed. The particular elements of set-up were analysed with respect to identification of parameters influencing the measurement quality. Local values of the ki.a coefficient for the water-air system were analysed using a self-aspirating disk impeller of diameter dm — 125 mm.
EN
On the basis of theoretical and experimental analysis of the issue, a criterion equation was proposed allowing the deter- minination of medium coefficients of multiphase mass exchange for low values of Re.
PL
Przedstawiono wyniki badań dotyczących usuwania amoniaku z roztworów wodnych zawierających dwutlenek węgla w procesie desorpcji powietrzem. Dokonano doświadczalnej weryfikacji korelacji opisujących fizyczne współczynniki wnikania masy w obu fazach. Przedstawiono wyniki eksperymentalnej weryfikacji matematycznego modelu procesu. Przeprowadzone porównania wskazują na możliwość symulacji pracy desorbera przy satysfakcjonującym poziomie błędu predykcji.
EN
Experimental results of ammonia removal from aqueous solutions containing carbon dioxide by stripping with air have been presented. Correlations describing physical mass transfer coefficients in both phases have been verified experimentally. Mathematical model of the process has also been verified experimentally. Comparisons conducted pointed to the possibility of desorber simulation at satisfactory level of prediction error.