Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 37

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  współczynnik wnikania ciepła
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
Experimental research has been carried out for four individual heat exchanger constructions, i.e., plain double tube, turbulized double tube, plain U-bend and U-bend with turbulator. Tests were made for the water-water system. The study covered a wide measuring range, i.e., Re = 800–9000 – on the shell side, for a constant cold water temperature of 9°C and hot water of 50°C. The heat exchangers were made from copper tubes with external diameter of 10 mm and 18 mm respectively and wall thickness of 1 mm. The helicoidal vortex generator was made from brass wire with a diameter of 2.4 mm, coil diameter of 13 mm and pitch of 11 mm. For these geometries, the values of pressure drop, heat flux and heat transfer coefficient were determined. Wire coil turbulator increased the heat transfer coefficient (HTC) over 100% and pressure drop up by 100%. The comparison of heat transfer efficiency was performed based on the number of transfer units-effectivenes (NTU-ε) method. The modified construction achieved a similar efficiency. Economic analysis of wire coil turbulator was made to validate its use in the system. It showed that a coiled wire turbulator can greatly decrease the investment cost of the double tube heat exchanger while maintaining transferred heat at a constant level.
EN
The paper presents an experimental investigation of a silicone based heat exchanger, with passive heat transfer intensification by means of surface enhancement. The main objective of this paper was to experimentally investigate the performance of a heat exchanger module with the enhanced surface. Heat transfer in the test section has been examined and described with precise measurements of thermal and flow conditions. Reported tests were conducted under steady-state conditions for single-phase liquid cooling. Proposed surface modification increases heat flux by over 60%. Gathered data presented, along with analytical solutions and numerical simulation allow the rational design of heat transfer devices.
PL
Przedstawiono budowę stanowiska badawczego oraz metodykę z procedurą obliczeniową do wyznaczania współczynników wnikania, przewodzenia i przenikania ciepła przez lutnie elastyczne. Omówiono charakterystykę procesu wymiany ciepła przez przenikanie od czynnika grzewczego płynącego w cylindrycznym przewodzie do otoczenia.
EN
Design of test bench as well as methodology with calculation procedure for determination of convection and overall heat transfer coefficient as well as thermal conductivity for flexible ventubes is presented. Heat transfer process by convection from heating medium in a cylindrical duct to the surrounding environment is discussed.
PL
Wodne pompy ciepła są w Polsce najrzadziej stosowanymi pompami ciepła. Jest to spowodowane wysokimi kosztami inwestycyjnymi oraz skomplikowanymi uwarunkowaniami prawnymi. Cechują się one jednak wysokim współczynnikiem efektywności energetycznej w stosunku do innych rozwiązań. Prace takiego urządzenia rozpatrywać można w dwóch stanach, konwekcji swobodnej, kiedy mamy do czynienia ze zbiornikami wodnymi w których występują jedynie konwekcyjne ruchy wody spowodowane różnicą gęstości (stacjonarne zbiorniki wodne takie jak jeziora, stawy, przydomowe baseny) oraz konwekcji wymuszonej, kiedy istnieje ukierunkowany przepływ wody w zbiorniku (rzeki, morza, ścieki kanalizacyjne). Wydajność oraz efektywność energetyczna wodnej pompy ciepła w tych dwóch stanach znacznie się różni. Jak wynika z analiz teoretycznych oraz badań wstępnych przeprowadzonych na modelu wodnej pompie ciepła znajdującej się na Wydziale Techniki Morskiej i Transportu, wymuszony ruch wody na powierzchni parowacza wpływa korzystnie na charakterystyki energetyczne urządzenia. Badania wstępne w warunkach konwekcji wymuszonej prowadzone były w okresie letnim oraz zimowym, a poprzedzone zostały dokładnymi badaniami w warunkach konwekcji swobodniej w okresie całego roku. Obecnie trwają analizy oraz przygotowania do prowadzenia właściwych badań kształtowania się efektywności energetycznej wodnej pompy ciepła w warunkach konwekcji wymuszonej w okresie zimowym (w niskiej temperaturze wody, tw = 1-4°C
EN
Water source heat pumps are the least frequently used heat pumps in Poland. It follows high investment costs and the increasingly complex legal conditions. However, they are characterized by a high rate of energy efficiency compared to other solutions. The work of such a device may be viewed in two states, natural convection, when we are dealing with water reservoirs in which there are only a convective movement of water caused by different density (stationary water reservoirs such as lakes, ponds, backyard swimming pools) and forced convection, when there is a directed flow of water in the reservoir (rivers, sea, sewage drainage). Performance and energy efficiency water source heat pumps in these two states varies greatly. As follows from theoretical analysis and preliminary studies conducted on a model water source heat pump located at the Faculty of Maritime Technology and Transport, forced movement of water on the surface of the evaporator has a beneficial effect on the energy performance of the device. Preliminary studies in conditions of forced convection were conducted during the summer and winter, and were preceded by accurate research in the natural convection conditions throughout the year. Currently, analysis, and preparations are being made to conduct proper research development of the energy efficiency water source heat pump in conditions of forced convection for the winter (in the low water temperature, tw = 1-4°C).
PL
Artykuł przedstawia przegląd literatury w zakresie wymiany ciepła w upakowanym złożu warzyw. Przedstawione i opisane zostały różne podejścia w zakresie technik pomiaru oraz wyniki badań eksperymentalnych w postaci bezwymiarowych zależności korelacyjnych opisujących wymianę ciepła. W przeglądzie przeanalizowano metody pomiarowe odnoszące się głównie do wymiany ciepła w upakowanych złożach wykonanych ze sztucznych elementów o stałych regularnych kształtach tj. płaskich płyt, kuł lub cylindrów.
EN
The paper presents state of the art in problems of heat transfer in packed bed consisted of vegetables and/or fruits. Various approaches were presented along with possible formulations of the dimensionless relationships describing heat transfer. The presented review deals with packed bed consisted of the elements of the regular shapes, e.g. flat plates, balls, and cylinders.
PL
W artykule przedstawiono wykorzystanie metody przedmuchowej do pomiaru współczynnika wnikania ciepła w upakowanym złożu warzyw. Została przedstawiona i opisana metoda przedmuchowa (ang. single blow technique), a także przystosowanie jej do pomiarów z elementami złoża o skomplikowanej geometrii. Dodatkowo przedstawiono stanowisko pomiarowe skonstruowane do metody przedmuchowej wraz z wynikami pomiarów, jakie uzyskano przy badaniu złoża marchwi.
EN
The paper presents the application of the single blow technique to mea-sure of heat transfer coefficient in packed bed of vegetables. The methodology of the measurement approach was presented along with its adjustment for the measurements with bed elements of complex geometry. The testing rig was also presented. The experimental results obtained for the packed bed composed of carrots were presented.
EN
The interrelation between fuzzy logic and cluster renewal approaches for heat transfer modeling in a circulating fluidized bed (CFB) has been established based on a local furnace data. The furnace data have been measured in a 1296 t/h CFB boiler with low level of flue gas recirculation. In the present study, the bed temperature and suspension density were treated as experimental variables along the furnace height. The measured bed temperature and suspension density were varied in the range of 1131–1156 K and 1.93–6.32 kg/m3, respectively. Using the heat transfer coefficient for commercial CFB combustor, two empirical heat transfer correlation were developed in terms of important operating parameters including bed temperature and also suspension density. The fuzzy logic results were found to be in good agreement with the corresponding experimental heat transfer data obtained based on cluster renewal approach. The predicted bed-to-wall heat transfer coefficient covered a range of 109–241 W/(m2K) and 111–240 W/(m2), for fuzzy logic and cluster renewal approach respectively. The divergence in calculated heat flux recovery along the furnace height between fuzzy logic and cluster renewal approach did not exceeded ±2%.
PL
W pracy prezentowanej w artykule przeprowadzono analizę czasu zamrażania 10 wybranych owoców (agrest, borówki, jabłka, jagody czarne, maliny, porzeczki czarne i czerwone, śliwki, truskawki i wiśnie). Obliczono i porównano czas zamrażania owoców, w zależności od wartości współczynnika wnikania ciepła oraz temperatury końcowej owoców (-18 i -30oC). Niezależnie od wartości współczynnika wnikania ciepła oraz temperatury końcowej owoców, najkrótszy czas zamrażania otrzymano dla porzeczek czarnych, a najdłuższy dla śliwek. Zaproponowano model potęgowy przydatny do szybkiego oszacowania czasu zamrażania owoców.
EN
In the work presented in the article analyzes freezing time 10 selected fruits (gooseberries, red whortleberries, apples, blueberries, raspberries, black and red currants, plums, strawberries and cherries). Calculated and compared fruit freezing time, depending on the value of heat transfer coefficient and the final temperature of fruits (-18 and -30oC). Irrespective of the value of heat transfer coefficient and the final temperature of fruits, the shortest freezing time obtained for black currants and the longest for plums. Proposed powerlaw model useful to estimate the freezing time of fruits.
PL
W pracy zaprezentowano metodę intensyfikacji wymiany ciepła za pomocą mechanicznego zaburzania termicznej warstwy przyściennej. Podano metodę wyznaczania współczynnika wnikania ciepła w takich warunkach oraz przedstawiono wyniki badań eksperymentalnych. Mechaniczne zrywanie termicznej warstwy przyściennej jest jedną z aktywnych metod intensyfikacji wymiany ciepła. Laminarna warstwa przyścienna temperatury stanowi główny opór cieplny w procesie wymiany ciepła. Usunięcie tej warstwy za pomocą obrotowych elementów mechanicznych (skrobaków) skutkuje zmniejszeniem całkowitego oporu przenikania ciepła, a przez to zwiększeniem przekazywanego strumienia ciepła. Badania przeprowadzono na specjalnie do tego celu zaprojektowanym stanowisku eksperymentalnym. Czynnikiem roboczym było powietrze. Zbadano wpływ prędkości obrotowej łopatek skrobiących na wymianę ciepła. Wyniki badań zostały zaprezentowane w formie wykresów.
EN
The energy balance and heat exchange for newborn baby in infant care bed environment (radiant warmer) are considered. Convective and radiant heat losses from an infant in radiant warmer were studied using copper cast anthropomorphic thermal manikin and controlled climate chamber setup. The total body heat loss was measured for several mean skin and ambient temperatures, leading to total heat transfer coefficient estimation.
PL
Rozważany jest bilans energii oraz mechanizmy wymiany ciepła dla noworodka w otwartym inkubatorze dla niemowląt. Wykorzystano miedziany antropomorficzny manekin termiczny noworodka do zbadania konwekcyjnej i radiacyjnej wymiany ciepła z otoczeniem w komorze klimatycznej. Zmierzono całkowity strumień traconego ciepła dla wybranych średnich temperatur skóry oraz otaczającego powietrza, a następnie wyznaczono konwekcyjny współczynnik wnikania ciepła.
EN
Experimental research has been carried out in a supercritical circulating fluidized bed combustor in order to indicate the effect of the bed particle size on bed-to-wall heat transfer coefficient. The bed inventory used were 0.219, 0.246 and 0.411 mm Sauter mean particles diameter. The operating parameters of a circulating fluidized bed combustor covered a range from 3.13 to 5.11 m/s for superficial gas velocity, 23.7 to 26.2 kg/(m2s) for the circulation rate of solids, 0.33 for the secondary air fraction and 7500 to 8440 Pa pressure drop. Furthermore, the bed temperature, suspension density and the main parameters of cluster renewal approach were treated as experimental variables along the furnace height. The cluster renewal approach was used in order to predict the bed-to-wall heat transfer coefficient. A simple semi-empirical method was proposed to estimate the overall heat transfer coefficient inside the furnace as a function of particle size and suspension density. The computationally obtained results were compared with the experimental data of this work.
EN
This paper presents the results of studies in two phase gasliquid flow around tube bundle in the model of shell tube heat exchanger. Experimental investigations of heat transfer coefficient on the tubes surface were performed with the aid of electrochemical technique. Chilton-Colburn analogy between heat and mass transfer was used. Twelve nickel cathodes were mounted on the outside surface of one of the tubes. Measurement of limiting currents in the cathodic reduction of ferricyanide ions on nickel electrodes in aqueous solution of equimolar quantities of K3Fe(CN)6 and K4Fe(CN)6 in the presence of NaOH basic solution were applied to determine the mass transfer coefficient. Controlled diffusion from ions at the electrode was observed and limiting current plateau was measured. Measurements were performed with data acquisition equipment controlled by software created for this experiment. Mass transfer coefficient was calculated on the basis of the limiting current measurements. Results of mass transfer experiments (mass transfer coefficient) were recalculated to heat transfer coefficient. During the experiments, simultaneously conducted was the the investigation of two-phase flow structures around tubes with the use of digital particle image velocimetry. Average velocity fields around tubes were created with the use of a number of flow images and compared with the results of heat transfer coefficient calculations.
PL
W artykule przedstawiono wyniki badań intensywności chłodzenia blach grubych metodą natryskową, przy użyciu dyszy wodno-powietrznej, firmy Lechler. Uzyskane wyniki stanowią podstawę do zdefiniowania współczynnika wnikania ciepła dla różnych ustawień dyszy natryskowej względem chłodzonej powierzchni oraz dla różnych wartości nastaw ciśnienia powietrza oraz dla stałego ciśnienia wody. Badania przeprowadzono na próbce o wymiarach 160 × 35 × 20 mm. Do badań użyta została próbka wykonana ze stali API5L. Przedstawione w pracy badania realizowano w warunkach laboratoryjnych w IPPiIB, na urządzeniu do wyznaczania współczynnika chłodzenia dysz natryskowych.
EN
The paper presents results of research of the cooling intensity of air-water nozzle. The results was allowed to elaborate a map of the distribution of heat transfer coefficient for constant cooling water pressure, a variables distance from the nozzle to the cooling surface and variables amounts of pressure air. For research steel X75 was used. The obtained results allow the execution a computer simulation of effect of cooling intensity on the final product’s structure. Research presented in the work carried out in the laboratory in IPPiIB the device for determining the coefficient of cooling spray nozzles.
PL
Celem pracy była doświadczalna charakterystyka współczynnika wnikania ciepła od warzyw do powietrza podczas ich zamrażania metodą odwróconej fluidyzacji. Wartości współczynnika wnikania ciepła wyznaczano pośrednio poprzez pomiar gęstości strumienia wnikającego ciepła, mierzonej przy użyciu czujnika Heat Flux Sensor. Złoża poddawane zamrażaniu formowano z prób warzyw w postaci plastrów o wymiarach 3x3x0,5 cm. Wyniki z podstawowej części badań eksperymentalnych wykorzystano do opracowania modelu obliczeń liczby Nusselta, który powstał poprzez adaptację zależności Nu = C·Rem ·Prn. Podstawowy wzór modelu o postaci Nux = 0,353·Rex608 charakteryzuje bezwymiarowo zależność współczynnika wnikania ciepła od parametrów procesu i obowiązuje w zakresie wartości liczb Reynoldsa 8000≤Rex≤30000. Weryfikację tej zależności przeprowadzono poprzez wszechstronne porównanie wyników uzyskanych na jej podstawie z rezultatami do-świadczeń w tych samych warunkach procesu. Analiza weryfikacyjna polegała na statystycznej ocenie względnego błędu obliczeń, charakterystyce regresji wartości liczby Nusselta i ocenie dopasowania rozkładów wyników obliczeń liczby Nu do rozkładów liczby Nusselta, uzyskanych według danych eksperymentalnych. Stwierdzono istnienie silnego skorelowania wartości współczynnika wnikania ciepła, otrzymywanych wg proponowanego modelu, z wynikami uzyskanymi na drodze eksperymentalnej.
EN
The research objective was to carry out experimental characteristics of a heat transfer coefficient during the impingement fluidized freezing of vegetables. Heat transfer coefficient values were determined by the intermediate measuring of heat flux density by Heat Flux Sensor. The beds undergoing the freezing process were formed from the vegetable sample slices of 3x3x0.5 cm dimensions. The basic model formulation Nux = 0.353·Rex 0,608 represents a dimensionless dependence of a heat transfer coefficient on the process parameters and is valid for 8000
PL
W artykule przedstawiono budowę przykładowego regeneratora cieplnego o nieruchomym wypełnieniu ceramicznym. Przedstawiono definicje wyznaczania efektywności cieplnej regeneratora, a następnie pokazano, jak na podstawie definicji i danych doświadczalnych wyznaczyć efektywność cieplną. Zaprezentowano szkic metodologii określenia efektywności regeneratora na podstawie modelu teoretycznego zaproponowanego przez Hausena z uzupełnieniem Bactilica i Dragutiniwica. Na koniec zaprezentowano przykładowe wyniki efektywności porównując wyniki doświadczalne z modelem teoretycznym uzyskując bardzo dobrą zgodność.
EN
The article presents the construction of a sample of a stationary thermal regenerator ceramic filling. Presents the definitions determination of thermal efficiency regenerator, and then shown as based on the definition and the experimental data determine the thermal efficiency. Then presents the methodology to determine the effectiveness of the regenerator with a stationary filling based on a theoretical model proposed by Hausen. At the end of the sample results are presented using the definition of efficiency and the theoretical model.
EN
This paper presents a method, which allows determining of the heat flux in combustion chambers of power steam boilers. The design of a thermometric insert used for measuring the heat flux has been described. The heat flux absorbed by the water-walls of the boiler has been determined on the basis of the changes of the metal temperature in the area of the fireside face and the internal surface. The temperatures measured within the inserts allowed also to determine the heat transfer coefficient on the inner surface. The temperature on the rear, external surface of the water-wall tube, which is close to the water-steam temperature, was also measured.
PL
W pracy przedstawiono uproszczoną metodę wyznaczania gęstości strumienia ciepła przejmowanego przez powierzchnię ogrzewalną parownika kotła energetycznego. Omówiona została konstrukcja wstawki termometrycznej służącej do pomiaru gęstości strumienia ciepła. Gęstość strumienia ciepła przejmowanego przez rury ekranowe komory paleniskowej kotła wyznaczana jest w oparciu o pomiar temperatury materiału wstawki termometrycznej od strony komory paleniskowej w czterech punktach. Opracowana metoda umożliwia również wyznaczenie współczynnika wnikania ciepła na powierzchni wewnętrznej wstawki. Mierzona jest również temperatura z tyłu wstawki termometrycznej, której wartość jest bardzo zbliżona do temperatury mieszaniny parowo-wodnej.
PL
Praca dotyczy sposobu obliczania wartości współczynnika wnikania ciepła w warunkach przepływu dwufazowego. Scharakteryzowano w niej równania proponowane w literaturze przedmiotu dla układów dwuskładnikowych. Na podstawie danych eksperymentalnych dokonano oceny skuteczności- metod słusznych dla układów gaz - ciecz w odniesieniu do układów ciecz - ciecz.
EN
The paper describes methods for heat transfer coefficient calculation in two-phase flow. The literature equations for predicting heat transfer in two-component systems are presented. On basis of experimental data the effectiveness of calculation methods for heat transfer in liquid — liquid systems originally used for calculations of heat transfer in gas - liquid systems was evaluated.
PL
W pracy badano proces zamrażania żywności wykorzystując urządzenie o jednostronnym systemie impingement z odbiciem strumieni powietrza. Współczynnik wnikania ciepła wyznaczano metodą zamienników w warunkach: prędkość przepływu powietrza 22 m/s, temperatura -7°C i -15°C. Uzyskane w badaniach wartości współczynnika wnikania ciepła wahały się w granicach od 112 do 122 W/(m2K), a po stronie powietrza od-bitego od dna komory roboczej od 89 do 96 W/(m2K).
EN
The food freezing process realized by using the one side impingement system with air flow reflection was investigated. The overall heat transfer coefficient was determined by using a copper piąte instead of food in conditions: air velocity 22 m/s, its temperaturę -7°C and -15°C. The values of heat transfer coefficient received in conditions of research were in the rangę of 112 - 122 W/(m2K), and from 89 to 96 W/(m2K) on the direction of reflected air flow.
PL
Przedstawiono metodę wyznaczania efektywnego współczynnika wnikania ciepła w cyrkulacyjnej warstwie fluidalnej przy użyciu sieci neuronowej. W celu uzyskania niezbędnej liczby danych uczących, stworzono model matematyczny opisujący proces wymiany ciepła w warunkach cyrkulacyjnej warstwy fluidalnej. Poprawność modelu potwierdzona została poprzez porównanie z danymi uzyskanymi z pomiarów na kotle o mocy cieplnej 670 MW, wykonanych dla różnych warunków eksploatacyjnych. Wykorzystując otrzymane wyniki obliczeniowe określono wpływ parametrów ruchowych na wartość efektywnego współczynnika wymiany ciepła. Z uwagi na złożoność opisywanych zjawisk, a stąd wysokie wymagania obliczeniowe stawiane przez model pod względem liczby parametrów wejściowych, stworzono model oparty na technice sieci neuronowych, pozwalający na łatwe wyznaczenie wartości efektywnego współczynnika wymiany ciepła.
EN
Presented is a method to determine the effective heat transfer coefficient with the use of neural network. Formulated is a mathematical model describing heat exchange process in conditions of fluidized circulating bed.The model correctnessis certified by comparison with data obtained from measurements carried out on a 670 MW capacity boiler operated under various conditions. Determined is, on the basis of calculation results, the influence of operational parameters on the effective heat transfer coeffcient value. Because of complicated character of the phenomena described - and that is why computation requirements concerning input parameters are so high - a model based on neural network technology is formulated enabling easy determining of the effective heat transfer coefficient value.
EN
The results of experimental studies on the distribution of a local heat transfer coefficient on the vertical wall of the agitated vessel have been presented. Four various type turbine impellers were used (Rushton turbine, paddle with 6 pitched blade of the angles of beta = 45, 90 and 135°). The experiments were carried out for the Newtonian and shear-thinning fluids without yield stress (Na-CMC and guar gum).The potassium ferri-and ferrocyanide solutions with the sodium hydroxide and potassium sulphate as the supporting electrolytes have been used as the Newtonian model solutions. For the shear-thinning media the formula of the Reynolds number proposed by Metzner and Otto Re(MO), has been applied. The results of the experimental studies in the graphical form have been presented. The common relationships for the Newtonian and non-Newtonian fluids have been obtained.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.