Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 24

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
This paper presents experiments conducted by various researchers on the purification of food industry wastewater in sequential batch reactors (SBR). The literature review covers such issues as 1) biological purification in SBR of wastewater containing molasses with a chemical oxygen demand (COD) of the order of 100,000 mgO2/dm3, 2) purification of wastewater from fish freezing in a hybrid system, 3) a SBR with granulated sludge and 4) membrane filtration or purification of abattoir wastewater with granulated sludge. The purification of dairy wastewater in the SBR system has also attracted considerable interest; the literature review therefore covers various methods of wastewater treatment, for example, the membrane SBR system and the anaerobic-aerobic (AF-SBR) system, applied on a very small production scale. This paper also presents the results of experiments conducted by these authors, involving purification of model dairy wastewater in the SBR system with the use of aids, such as pre-aeration of raw wastewater, introducing an additional anoxic phase or using natural zeolites. The degree of ammonium nitrogen removal achieved in the experiments, was high and equalled 97.5 %; the value for total phosphorus was 93 % and for total organic carbon – 99 % under the most favourable conditions.
PL
W pracy zaprezentowano doświadczenia różnych badaczy w oczyszczaniu ścieków przemysłu spożywczego w sekwencyjnych reaktorach porcjowych (SBR). Przegląd literatury obejmuje takie zagadnienia, jak: 1) biologiczne oczyszczanie w reaktorach SBR ścieków zawierających melasę o stężeniu ChZT rzędu 100 000 mgO2/dm3, 2) oczyszczanie ścieków powstających w procesie mrożenia ryb w układzie hybrydowym, 3) reaktor SBR z osadem granulowanym oraz 4) filtracja membranowa czy oczyszczanie osadem granulowanym ścieków pochodzących z rzeźni. Sporym zainteresowaniem cieszy się również oczyszczanie ścieków przemysłu mleczarskiego w systemie SBR, dla tego w przeglądzie literatury zawarto różne metody oczyszczania tych ścieków m.in. oczyszczanie w membranowym systemie SBR, a także w układzie beztlenowo-tlenowym (AF-SBR), zastosowanym w skali ćwierć technicznej. Przedstawiono także wyniki badań własnych w oczyszczaniu modelowych ścieków przemysłu mleczarskiego w systemie SBR z zastosowaniem czynników wspomagających, takich jak wstępne napowietrzanie ścieków surowych, wprowadzenie dodatkowej fazy anoksycznej, czy zastosowanie zeolitów naturalnych. W przeprowadzonych badaniach uzyskano wysoki stopień usunięcia azotu amonowego wynoszący 97,5 %, fosforu ogólnego wynoszący maksymalnie 93 % i ogólnego węgla organicznego wynoszący w najbardziej sprzyjających warunkach prawie 99 %.
6
Content available remote Effect of fulvic acids on the process of water purification on filtration beds
63%
EN
This study examined the process of filtering of infiltrated water containing exessive amounts of iron, manganese, and fulvic acids through two filtration beds-sand and zeolite-exhibiting catalytic properties. The fulvic accids, that were added to the filterd water were extracted from mud in Kołobrzeg. The zeolite bed was modified with manganese oxide using our own technoogy and required periodic regeneration using 0.3% KMnO_4 solution. Our study showed the fulvic acids' negative effect on the process of water purification. The zeolite bed reduces this effect and is more effective than the quartz sand bed.
PL
W pracy przebadano proces filtracji wody infiltracyjnej o nadmiernej ilości żelaza, manganu i kwasów fulwowych przez dwa złoża filtracyjne: piaskowe i zeołitowe wykazujące właściwości katalityczne. Kwasy fulwowe dodawane do filtrowanej wody ekstrahowano z kołobrzeskiej borowiny. Złoże zeolitowe było modyfikowane tlenkami manganu według własnej technologii i wymagało okresowej regeneracji 0,3% roztworem KMnO(. Badania wykazały ujemny wpływ kwasów fulwowych na procesy oczyszczania wody. Złoże zeolitowe pomimo trudnych warunków oczyszczania wody jest efektywniejsze od złoża kwarcowo-piaskowego.
7
63%
PL
Na podstawie analizy histogramów zużycia wody można zauważyć, że pobór wody przez ośrodki sanatoryjno-wypoczynkowe w ciągu roku nie jest równomierny i zależy od liczby wypoczywających osób. Najmniejsze zużycie wody jest w miesiącach od stycznia do kwietnia oraz w listopadzie i grudniu, a największe od czerwca do września. Z wielkością poboru wody związane są ilości odprowadzanych do kanalizacji ścieków. A więc, w miesiącach maksymalnego poboru wody występuje równocześnie największe obciążenie oczyszczalni ściekami. Z analizy charakterystyki przedstawionej w tabeli 7 wynika, że ścieki pochodzące z ośrodków sanatoryjno-wypoczynkowych nie różnią się w zasadzie od typowych ścieków bytowo-gospodarczych [2, 3]. Średnie pH ścieków odprowadzanych z badanych ośrodków wynosi 7,6, zawartość substancji organicznych ulegających biodegradacji BZT5 262 mg O2/dm3, chlorków 99 mg Cl/dm3, utlenialność jest równa około 92 mg O2/dm3. Szczególną uwagę w tej analizie porównawczej zwraca wysoka średnia wartość substancji rozpuszczonych, która wynosi 1 021 mg/dm3 i wynika z dużej jej wartości otrzymanej dla ścieków odprowadzanych z ośrodka Lech (1 512 mg/dm3). W ośrodku tym są prowadzone liczne zabiegi, które są źródłem powstawania znacznej ilości substancji rozpuszczonych w ściekach i podwyższonego ich zasolenia. W ośrodku tym jest również najwyższe zużycie wody w przeliczeniu na osobo-dzień (Qdj = 0,336 m3/osobodzień). Problemem mogą być wody z solanek wykorzystywanych w zabiegach, jednak stężenie ich jest na tyle małe (maksymalnie 6,2%), że przy rozcieńczeniu pozostałymi ściekami nie muszą wpływać istotnie na ostateczną jakość ścieków. Obecnie typowe ścieki powstające po zabiegach leczniczych odbierane są przez specjalistyczne firmy, które zajmują się ich oczyszczaniem. Większość ośrodków zrezygnowała również z własnej pralni, co w dużym stopniu wpływa na wyrównanie jakości ścieków odprowadzanych przez poszczególne ośrodki. W najbliższym czasie problemem może się okazać zakaz przeznaczania odpa-dów kuchennych na paszę dla zwierząt, ponieważ wszystkie odpady kuchenne muszą być teraz rozdrabniane i odprowadzane do kanalizacji lub mogą je odbierać specjalistyczne firmy. Współczynnik nierównomierności miesięcznego przepływu ścieków dla wszystkich badanych ośrodków mieści się w przedziale wartości od 1,30 do 1,58 i jego wartość jest odwrotnie proporcjonalna do wskaźnika miesięcznego odpływu ścieków.
EN
In many health resorts sewage from holiday camps are piped off straight to the city sewage treatment plant. Regular flows of sewage decide about efficiency of sewage treatment plant. Quantity of sewage piped off from each holiday camp is closely-coupled with number of people resting in that holiday camp and it is usually very diverse within a year. Composition of sewage piped off from most holiday camps usually represent typical municipal sewage. In some camps, especially sanatorium camps, therapeutic exercises are made. For example compress from therapeutic mud, brine bath, underwater massage etc. These curative treatments could have influence on quality of piped off sewage, that might be concentrated or diluted. Sewage from therapeutic mud and brine bath often should be treated before piping off to the sewage system. Sewage from kitchen or laundry could be a problem. Sewage from kitchen usually are subacid, contain a lot of suspension, organic matter defined by BOD and COD, total dissolved solids and fats. Sewage from laundry contain surfactants, phosphates and have lightly alkaline reaction. Diverse composition of sewage also has negative influence on work of sewage treatment plant. Unfortunately there are very few papers concerning water and sewage management in health resorts. There is no information about sewage composition stability and also regularity of sewage piped off in different season, particularly in holiday season and in off-season months. Therefore authors decided to carry analysis of water and sewage management as well as quality and quantity of sewage piped off to sewage treatment plant from four randomly selected holiday camps. Four health resorts situated in Kołobrzeg city were analyzed. The analysis was carried out basing on data from each holiday camp and from Municipal Waterworks an Sewage System Company in Kołobrzeg. Basing on available data it might be noticed that sewage from holiday camps are very similar to the typical municipal sewage. Water consumption is very irregular and depends on number of resting people. Lowest water consumption is from January till April and in November and De-cember. Highest water consumption appears from June till September. In highest water consumption months also highest load of sewage treatment plant appears. Brine bath sewage might be a problem but their concentration is low enough so when they are diluted with rest of the sewage from holiday camp they won't have influence on final sewage quality. Currently typical sewage from therapeutic exercises are taken away by specialized company. Most of holiday camps have resigned from using their own laundries which caused equalization of sewage quality.
8
Content available remote Kinetics of dairy wastewater treatment in the SBR system
63%
EN
There are two kinds of wastewater that may originate at a dairy plant: post-production and non-production waste. Dairy wastewater treatment is a process consisting of several stages. In the pre-treatment stage, fat and sand is removed from wastewater. The second stage treatment consists mainly in aerobic treatment with activated sludge, advanced oxidation methods and an anaerobic treatment. In recent years, more and more plants have been treating their wastewater in SBR type reactors, because they are flexible at work and enable the user to change conditions to suit the variable quality of raw wastewater. The research on the kinetics of the wastewater treatment process in an SBR reactor has been conducted. The removal of several factors such as nitrogen compounds, TOC, phosphorus and the kinetics of oxygen concentration and redox potential have been analyzed. The experiment was carried out in two 12 dm3 volume SBR reactors in a lab-scale. The SBR reactors were operated with a cycle time of 12 hours with three hours of filling, seven hours of aeration, an hour of sedimentation, half an hour of decantation and half an hour of technical break. In presented research average parameters of raw wastewater were: TOC 329 mg C/dm3, ammonium nitrogen 11.15 mg NNH4/dm3, and total phosphorus 15.42 mg P/dm3.
PL
Na terenie zakładów mleczarskich powstają dwa rodzaje ścieków: poprodukcyjne i nieprodukcyjne. Oczyszczanie ścieków przemysłu mleczarskiego przebiega kilkuetapowo. W oczyszczaniu wstępnym ze ścieków usuwane są min. tłuszcze i piasek. Oczyszczanie drugiego stopnia to głównie oczyszczanie tlenowe metodą osadu czynnego, ale również metody pogłębionego utlenienia, a także oczyszczanie beztlenowe. W ostatnich latach coraz więcej zakładów decyduje się na oczyszczanie ścieków w sekwencyjnych reaktorach biologicznych (SBR), ponieważ wykazują się wysokim stopniem elastyczności w działaniu, pozwalając użytkownikowi zmieniać warunki, tak, aby dopasować je do zmieniającej się jakości ścieków surowych. W przeprowadzonych badania prześledzono kinetykę oczyszczania syntetycznych ścieków przemysłu mleczarskiego w systemie SBR. Analizowano usunięcie związków azotu, fosforu, węgla organicznego a także kinetykę stężenia tlenu rozpuszczonego i potencjału redoks. Badania przeprowadzono w skali laboratoryjnej w dwóch reaktorach o pojemności 12 dm3 każdy. Reaktory pracowały w cyklu 12-godzinnym, z czego napełnianie trwało 3 godziny, napowietrzanie 7 godzin, następnie była godzinna sedymentacja, półgodzinna dekantacja i półgodzinna przerwa techniczna. W prezentowanych badaniach średnie stężenie zanieczyszczeń w ściekach surowych wynosiło: OWO 329 mg C/dm3, azotu amonowego 11,15 mg NNH4/dm3, a fosforu ogólnego 15,42 mg P/dm3.
9
Content available remote Wpływ składu wody na proces usuwania manganu na złożu zeolitowym i piaskowym
63%
EN
Comparison of effectiveness of manganese removal process in underground waters with different compositions of model water. Examined parameters concentration of manganese, iron, ammonium and nitrate ions, pH, conductivity, redox potential. Comparison of zeolite and sand deposits effectiveness.
12
Content available remote Ocena skuteczności zastosowania zeolitów w oczyszczaniu ścieków komunalnych
51%
EN
Characteristics of sewage treatment plant in Dygowo - technological diagram. Results of biological sewage treatment using zeolite. Influence of zeolite dose on organic substances' concentration. Changes in general concentration value of organic carbon in raw sewage and in sewage treated in SBR-1 zeolite reactor.
13
Content available remote Zastosowanie zeolitów do oczyszczania wody
51%
PL
Zeolity naturalne ze względu na swoje właściwości jonowymienne i sorpcyjne mogą być szeroko stosowane, szczególnie w inżynierii środowiska. Główne fizykochemiczne właściwości zeolitów to duża pojemność adsorpcyjna, selektywność, pojemność jonowymienna oraz odporność na działanie kwasów i podwyższonej temperatury. Zeolity naturalne mogą z powodzeniem znaleźć zastosowanie jako materiał filtracyjny, czyli zastąpić piasek kwarcowy. Mogą być również stosowane do oczyszczania wody o dużej mętności. Ponadto wykazują duże powinowactwo do jonów amonowych, metali ciężkich oraz alkalicznych. Na przykład klinoptylolit łatwo adsorbuje jony Hg2+, Ni2+, Cr3+, Cu2+, Cd2+, Zn2+, Pb2+, Co2+, Mn2+, Ni2+, Fe2+ i inne. Wciąż jednak ilość przeprowadzonych badań pod kątem zastosowania zeolitów do oczyszczania wody jest niewystarczająca. Szczególnie brakuje danych dotyczących adsorpcji substancji organicznych, takich jak np. substancje humusowe. Należy sądzić, że proces adsorpcji kwasów humusowych charakteryzujących się znaczną ilością grup funkcyjnych ujemnych (karboksylowe, fenolowe) na elektroujemnej powierzchni zeolitu jest utrudniony. Wykazanie braku lub niewielkiej adsorpcji tych substancji na zeolitach jest jednoznaczne z eliminacją glinokrzemianów jako materiałów filtracyjnych możliwych do wykorzystania w procesie uzdatniania wody powierzchniowej. Dlatego w pracy przeprowadzono badania oceniające proces adsorpcji kwasów humusowych na zeolitach naturalnych. Ocenę procesu przeprowadzono w oparciu o wartości potencjału elektrokinetycznego cząstek zeolitu i kwasów humusowych.
EN
In this study an analysis of coloured water coagulation with zeolites participation as an assisting substance was made. On the basic of chemical analysis (trace metals content) of humic acids that cause water colour and elektrokinetic potential value of acids zeolites as well as efficientcy of colour removal coagulation proces was described and conditions of colour removal on zeolites were proposed.
PL
Omówiono wyniki prac, celem których było wykrycie ewentualnych eksploatacyjnych wad materiałowych metodą magnetyczno-proszkową w konstrukcyjnie istotnych elementach ustroju nośnego koparki w związku z jej zamierzoną odnową i adaptacją do dalszej wieloletniej eksploatacji.
EN
Results of works aiming at detection of possible material exploitation failures have been presented in the paper. Magnetic powder test method has been applied for tests of crucial elements of excavator supporting structure in relation to its renovation and adaptation for further long-term exploitation.
PL
W publikacji przedstawiono badania nad wykorzystaniem zeolitu naturalnego modyfikowanego do doczyszczania ścieków komunalnych. Badania przeprowadzono w skali laboratoryjnej w układzie sekwencyjnych reaktorów porcjowych typu SBR oraz złoża filtracyjnego, którego wypełnienie stanowił zeolit modyfikowany manganem. Procesowi poddawano ścieki syntetyczne przygotowane w oparciu o niezbędne składniki organiczne oraz mineralne. Ścieki po procesie biologicznego oczyszczania osadem czynnym w reaktorze kierowano na kolumnę filtracyjną. Ze względu na cykliczność pracy reaktora ścieki oczyszczano na złożu w sposób porcjowy, utrzymując je w formie zalanej. Badania prowadzono kilkuetapowo: bez regeneracji złoża, z regeneracją okresową oraz regeneracją cykliczną po każdorazowym cyklu pracy reaktora SBR. Uzyskane wyniki usunięcia związków azotu, fosforu oraz węgla zweryfikowano na ściekach rzeczywistych. W tym celu na kolumnę filtracyjną podawano ścieki biologicznie oczyszczone z osadnika wtórnego oczyszczalni miejskiej w sposób ciągły, regenerując różnymi metodami po wyczerpaniu właściwości katalitycznych złoża. Przeprowadzona weryfikacja wykazała dużą skuteczność zastosowanego układu doczyszczania ścieków w zakresie usuwania azotu amonowego oraz związków węgla i fosforu. Obserwowano również obniżenie przewodności właściwej ścieków oraz niewielki wzrost stężenia azotu azotanowego.
EN
The paper presents research on using natural zeolite modified for cleaning municipal sewage thoroughly. The research was carried out in laboratory scale in system composed of Sequencing Batch Reactors and filter bed with zeolite modified with manganese ions. Synthetic sewage prepared on the basis of organic and mineral components was used for cleaning process. After biological treatment with activated sludge in the reactor, the sewage was directed to filtration column. Due to the fact that reactor was operating in cycles; the sewage was treated on the bed in portioned way and kept submerged. The research was carried out in a few stages: without regeneration of the bed, with periodic regeneration and cyclical after each cycle of SBR reactor operation. Obtained results of nitrogen, phosphorous and carbon compounds removal were verified on real sewage. For that purpose biologically treated sewage was directed in a continuous way to a filtration column from secondary settling tank of sewage treatment plant, regenerating bed with different methods after exhausting its catalytic properties. Verification showed great effectiveness of used configuration for removal ammonia nitrogen, carbon and phosphorous compound from sewage. Decrease in electrical conductivity of sewage and a slight increase of nitrate nitrogen concentration was observed. The research showed great effectiveness of proposed filtration configuration for sewage treatment and a possibility of bed regeneration with keeping its work effectiveness.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.