The influence of sample thickness and grain size of Conventional Grain-Oriented (CGO) and High Permeability Grain-oriented (HGO) steels on Magnetic Barkhausen Noise (MBN) of Epstein strips has been examined. It might be expected that MBN decreases with increasing sample thickness due to eddy current damping but the measurements show that the average domain width, hence the grain size influences MBN in strips less than 0.35 mm thick. From 0.35 mm and above, both strip thickness and domain width influence MBN in CGO and HGO.
PL
Zbadano wpływ grubości próbki i rozmiaru ziarna dla stali konwencjonalnej o ziarnie zorientowanym (CGO) i stali o wysokiej przenikalności i ziarnie zorientowaym (HGO) na paskach Epsteina. Można oczekiwać, że amplituda sygnału Barkhausena MBN zmniejsza się wraz ze wzrostem grubości próbki z uwagi na efekt tłumienia od prądów wirowych, lecz pomiary wykazały, że średnia szerokość domen, związana z rozmiarem ziarna, ma wpływ na MBN w paskach o grubości mniejszej niż 0,35 mm. Dla grubości 0,35 mm i powyżej, grubość paska i szerokość ziarna mają wpływ na MBN zarówno dla stali CGO i HGO.
PL
Efektywność ekranowania magnetycznego przy użyciu zorientowanej blachy elektrotechnicznej została zbadana dla zakresu częstotliwości 0,01-100 kHz. Zależność efektywności od częstotliwości została opisana w związku z anizotropią materiału <100> i <110> po obwodzie cylindrycznych ekranów magnetycznych. Wartości efektywności wykazały różnice powyżej 50 kHz ekranów <100> i <110> przed i po wyżarzaniu odprężającym. Trójwymiarowe modelowanie FEM sugeruje, że rozkład prądów wirowych ma wpływ na efektywność ekranowania dla wyższych częstotliwości.
EN
Magnetic shielding effectiveness of grain oriented electrical steel was studied at 0.01-100 kHz magnetic fields. The frequency dependent effectiveness was clarified as to material anisotropy of <100> and <110> in circumferential direction of cylindrical shields. The effectiveness showed the difference over 50kHz between the shields of <100> and <110> before and after stree-relief annnealing.3D FEM analysis suggested eddy current distribution affects the shielding effectiveness at higher frequency.
3
100%
EN
This paper deals with the dynamic vector magnetic hysteretic engineering model, “Dynamic E&S Model”, which can analyze the effect of eddy current under the vector magnetic behavior. It is well known that the vector of magnetic field strength H is not always parallel to the magnetic flux density B in the core. Furthermore when the wave of magnetic flux is distorted, the eddy current occurs. We will report the dynamic magnetic characteristic analysis taken care of eddy current.
PL
Artykuł omawia wektorowe modelowanie właściwości dynamicznych materiałów magnetycznych, nazwane “Dynamiczny model E&S”. Model ten umożliwia analizę wpływu prądów wirowych na wektorowe właściwości dynamiczne materiałów magnetycznych. Wiadomo, że w materiałach magnetycznych kierunek wektora pola magnetycznego nie zawsze jest równoległy do kierunku indukcji. Ponadto prądy wirowe pojawiają się gdy strumień magnetyczny jest odkształcony. W artykule analizuje się wpływ prądów wirowych na właściwości dynamiczne.
EN
In medical or low conductivity electromagnetic induction tomography, a low frequency approximation (i.e. neglecting the diffusion effect) can significantly simplify the forward and inverse solutions. However, this approximation normally leads to the over prediction of the amount of eddy currents induced by the transmitter coil, and hence to an overestimation of the secondary voltage measured on the receiver coil. The reason is because the penetration of the field into the object is not correctly described and the skin effect is ignored. In effect, the theory assumes that the signal is coming from a larger-than-actual volume. This paper uses an exact analytical solution for a coil(s) near a stratified media derived from a full wave theory to evaluate the skin effect at a range of frequencies and compares it with a simple model which omits the skin effect. The error due to the approximation is evaluated and the highest frequency at which the approximation holds valid to within a defined error range is ascertained.
5
Content available remote Modelling of Magnetotherapy in the Healing of Knee Joint
100%
EN
The paper presents the method of establishing a computer model of the electromagnetic therapy connected with some knee joint problems. Two cases were considered: the arthritis of the knee and the fracture of bone. In both cases the analysis of eddy current distribution in the knee were made. It gave results which can be helpful in the planning of treatment. The paper presents the exemplary results of eddy current distribution inside a bone. A short discussion on the safety aspect of magnetotherapy has been carried out.
PL
W artykule przedstawiono numeryczna aplikacje niskoczęstotliwościowego algorytmu FDTD do symulacji prądów wirowych w modelu kolana ludzkiego. Analiza efektywności magnetoterapii zrealizowana została poprzez porównanie rozkładu pola magnetycznego i prądów wirowych w kolanie zdrowym i ze złamaniem. Ponadto, dokonano krótkiej dyskusji aspektów narazeniowch magnetoterapii w leczeniu ortopedycznym.
6
Content available remote Wpływ struktury domenowej na straty energii w materiałach magnetycznie miękkich
84%
PL
Praca stanowi przegląd modeli strat energii w materiałach magnetycznie miękkich, z uwzględnieniem wpływu struktury domenowej. Wskazano, że straty energii w materiałach magnetycznych wynikają z prądów wirowych generowanych w materiale w różnych skalach przestrzenno-czasowych. Stwierdzono, że takie podejście do opisu strat daje dla materiałów krystalicznych ilościową zgodność pomiędzy teorią a eksperymentem.
EN
The paper is an overview of energy loss models in soft magnetic materials, with taking an influence of domain structure into consideration. It was indicated that energy loss in soft magnetic materials resulted from eddy currents generated in material in different space-time scales. It was stated, that the aforementioned approach to energy loss description gave a quantitative agreement between theory and experiment in case of crystalline materials.
EN
Purpose: Determination and description of essential phenomena that occur during examination of two-layer structures with use of the eddy-current method. Development of guidelines to establish procedures that make it possible to find out optimum frequencies of eddy currents, for which measurements of the outer film covering the examined structure exhibit best performance. Estimation of errors that occur when measurements of both geometrical and electrical parameters of the upper film within the two-layer structures are carried out simultaneously. Design/methodology/approach: During the design and scalling of the devices based on phenomenon of eddy currents implying changes of contact coil impedance components, significant influence of the electromagnetic field frequency on measurement results was observed. Additionally, some other phenomena can be observed which causes invalid interpretation of devices indications. Basing on a mathematical model of a contact coil located above a conductive non-ferromagnetic two-layer plate, the sensitivities to the measured parameters are determined. The developed mathematical model serves and the basis to calculate theoretical values of errors when all parameters of the outer film on the examined structure are measured simultaneously. Findings: Depending on specific applications, recommendations enabling proper choice of the electromagnetic field frequency are formulated. Practical implications: Describred phenomena and calculations are useful for the designers of the devices utilising the phenomenon of eddy currents, and also for the users of flaw detectors and conductometers. Remarks included in this paper can be useful for proper interpretation of the observed results and phenomena. Originality/value: Determination of impact coefficients that define how parameters of the two-layer structure are vulnerable to impedance components of the measuring contact coil.
8
Content available remote Pole magnetyczne koncentrycznego układu przewodów rurowych
84%
PL
Przez rozwinięcie logarytmicznego potencjału wektorowego w szereg Fouriera wyznaczono pole magnetyczne generowane przez prąd w wewnętrznym niewspółosiowym ekranowanym przewodzie fazowym jako funkcję dwóch zmiennych r oraz 0 walcowego układu współrzędnych. W nieprzewodzących obszarach wewnętrznym i zewnętrznym pole elektryczne opisano równaniem Laplace'a, a w obszarze przewodzącym równaniem Helmholtza dla dwóch zmiennych. Równania te rozwiązano stosując metodę rozdzielenia zmiennych. Z klasycznych warunków brzegowych, uwzględniając przy tym także oddziaływanie zwrotne prądów wirowych, wyznaczono gęstość prądów wirowych indukowanych w ekranie. Umożliwiło to określenie pola magnetycznego we wszystkich obszarach koncentrycznego niewspółosiowego układu przewodów rurowych.
EN
By the expansion of logarithmic vector potential into a Fourier series the magnetic field generated by the current in the internal non-coaxial screened phase conductor as a function of two variables r and 0 of a cylindrical coordinate system was determined. In the non-conducting areas, internal and external, the electric field is described by Laplace equation, while in the conducting area by Helmholtz equation for two variables. These equations are solved using the separation of variables method. From the classic boundary conditions, taking into account the reciprocal interaction of eddy currents, we determine the density of eddy currents induced in the screen. It allowed determination of magnetic field in all areas of a concentric non-coaxial tubular conductor system.
EN
Purpose: To determine optimal frequency of the electromagnetic field that raises eddy currents during the search for surface defects in non-ferromagnetic materials or conductivity measurements by means of eddy currents methods. The frequency choice takes into consideration sensitivity of measuring device, depth of the eddy currents penetration and elimination of undesirable phenomena that affects result of the exploration. Design/methodology/approach: During the design and scalling of the devices based on phenomenon of eddy currents implying changes of contact coil impedance components, significant influence of the electromagnetic field frequency on measurement results was observed. Additionally, some other phenomena can be observed which causes invalid interpretation of devices indications. Basing on a mathematical model of a contact coil located above a conductive non-ferromagnetic plate, the sensitivities to the measured parameters are determined. Furthermore, a novel definition of the eddy currents penetration depth is proposed. Findings: Depending on specific applications, recommendations enabling proper choice of the electromagnetic field frequency are formulated. Practical implications: Describred phenomena and calculations are useful for the designers of the devices utilising the phenomenon of eddy currents, and also for the users of flaw detectors and conductometers. Remarks included in this paper can be useful for proper interpretation of the observed results and phenomena. Originality/value: A modified definition of the actual penetration depth of eddy currents proposed in the paper differs from the classical approach based on the 1/e level. This definition may be especially convenient and useful for operators utilising eddy current devices. Described sensitivity model facilitates setting up the devices for a specific task involved in a different technological process.
|
2008
|
tom Vol. 57, nr 1
23-40
EN
The paper presents a method which allows us to calculate directly the flux density and the eddy current density in an electromagnetic field. This proposed method is similar to the reluctance network method. However, reluctances are not used in the creation of the magnetic field network because it is quite difficult to determine them for non-linear materials. A new notation method of the components of the flux density, field intensity and eddy current density and their connections with space partition networks are also presented in this paper. Special attention is paid to taking into account the relations which connect flux densities and field intensities in the particular parts of a ferromagnetic material. The method presented in this paper can be helpful to calculate field distributions in non-linear environments, especially if the hysteresis phenomenon must be taken into account.
PL
W oparciu o całkową postać równań Maxwella sformułowano w artykule równania rozkładu pola magnetycznego i pola prądów wirowych w przestrzeni trójwymiarowej. Wielkościami bezpośrednio występującymi w równaniach są: indukcja magnetyczna, natężenie pola i gęstość prądów wirowych. Omówiono sposób oznaczania składowych tych wielkości oraz ich powiązanie z siatkami podziału przestrzeni występowania pól. Ilość równań koniecznych do wyznaczenia rozkładu pól jest ograniczona do sumy niezależnych oczek siatki pola magnetycznego i pola prądów wirowych. Znaczną uwagę poświęcono zagadnieniu uwzględnienia w obliczeniach nieliniowości materiałów ferromagnetycznych. W końcowej części artykułu zamieszczono przykładowe wyniki obliczeń numerycznych zmian pola magnetycznego i prądów wirowych przy wymuszeniu prądem przemiennym.
|
2012
|
tom nr 2
19-24
PL
W artykule przedstawiono ocenę możliwości zastosowania metody prądów wirowych do kontrolowania mikrostruktury poddanej oddziaływaniu obróbek mechanicznych - obróbki skrawaniem i kulowania. Wyniki badań koncentrują się na żeliwie sferoidalnym ausferrytycznym, wykazującym mikrostrukturę wrażliwą na oddziaływania mechaniczne poprzez obecność w niej austenitu metastabilnego. Próbki z dwóch rodzajów żeliwa poddane kulowaniu, bądź obróbce skrawaniem określonych powierzchni, wykazują rejestrowane za pomocą specjalistycznego oprzyrządowania zmiany charakterystyczne dla przemian mikrostrukturalnych. Wykazano, że za pomocą metody prądów wirowych można stwierdzić wzrost udziału, fazy ferromagnetycznej w warstwie wierzchniej materiału, poddanego oddziaływaniu mechanicznemu inicjującemu przemiany mikrostruktury. Ocena taka wymaga jednak doświadczenia badawczego, wiedzy o materiale testowanym oraz odpowiednich sond wiroprądowych zapewniających właściwą czułość pomiaru.
EN
The evaluation of eddy current method as the useful way to control microstructure changed by mechanical treatment - shot peening or machining is presented. Test results are focused on the austempered ductile iron. R is showed that microstructure is sensitive for mechanical influence due to presence of metastable austenite. Two types of austempered ductile iron samples after shot peening or machining have been investigated. Different sample surfaces revealed different characteristic microstructure transformation. By the use of the eddy current method it can be proved that ferromagnetic phase grows up in the top layer after machining and shot peening and these initiate rnicrostructural transformations. To make that kind of evaluation it is necessary to have research experience also basic knowledge about investigated material and appropriate eddy current probe of adequate sensitiveness.
12
Content available remote Skin-effect in Conductor of Rectangular Cross-section - Approximate Solution
84%
EN
Current distribution in massive conductor of rectangular cross section due to the skin-effect can be calculated approximately by two simple formulae. One was found in the literature, the second, based on constant surface current, was derived recently. In the paper the general approach based on iterative technique was derived for more precise calculations. Since some unusual features follow from the formulae, the experimental verification is necessary. As the current density cannot be measured, magnetic field of the conductor is calculated by the combination of analytical formula and numeric integration. Results exhibit acceptable agreement between approximation theory based on constant surface current and experiment. More accurate approximation requires more precise experiment.
PL
Analizowano rozkład prądu w przewodniku o przekroju prostoktątnym z uwzględnieniem efektu naskórkowości. Analizowano dwie metody - jedną znaną z literatury, drugą bazującą na stałym prądzie powierzchniowym. Ponieważ nie był możliwy bezpośredni pomiar gęstości prądu analizowano pole magnetyczne.
13
Content available remote Ekran cylindryczny w poprzecznym nierównomiernym polu magnetycznym
84%
|
2009
|
tom R. 85, nr 6
150-154
PL
Poprzez rozwinięcie logarytmicznego potencjału wektorowego w szereg Fouriera wyznaczono pole magnetyczne generowane przez prąd w zewnętrznym przewodzie fazowym jako funkcję dwóch zmiennych r oraz ? walcowego układu współrzędnych. Następnie wyznaczono pole magnetyczne oddziaływania zwrotnego prądów wirowych, co pozwoliło na określenie całkowitego pola magnetycznego na zewnątrz i we wnętrzu ekranu. Wykazano przy tym, że pola te są polami eliptycznymi. Zdefiniowano współczynnik oddziaływania zwrotnego ekranu i współczynnik zaekranowania. Zbadano wpływ konduktywności i wymiarów poprzecznych ekranu, jego odległości od osi przewodu fazowego oraz częstotliwości na wartości tych współczynników.
EN
By the expansion of logarithmic vector potential into Fourier's series the magnetic field generated by current in external phase conductor, which is a function depending on variables r and ? of a cylindrical coordinate system, was calculated. Then the magnetic field of reverse reaction of eddy currents enabled the determination of the total magnetic field outside and inside the screen. Moreover, it was demonstrated that these fields are elliptical. The coefficient of reverse reaction of the screen and the shielding coefficient were defined. We studied the influence of conductivity and transverse dimensions of the screen as well as its distance from the phase conductor and frequency on the value of these coefficients.
PL
Przedmiotem niniejszej pracy były nowe procedury badania grubości warstw za pomocą metody prądów wirowych. Dodatkowo, dla opracowania metody bezpośredniego wyznaczania grubości warstw za pomocą prądów wirowych, w pracy połączono podejście eksperymentalne z symulacją numeryczną bazującą na metodzie elementów skończonych (MES). Na podstawie przeprowadzonych pomiarów oraz obliczeń numerycznych, opracowana została metoda wyznaczania grubości warstw w elementach o złożonych kształtach.
EN
The thesis concerns applications of the Eddy Current (EC) for measurements of the thickness of the layers. Additionally, the special finite element models have been developed which simulate eddy currents in materials with surface layers. These models can be used for direct measurements of the thickness of the induction hardening layers in complex shape elements.
15
Content available remote Pole magnetyczne przewodu ekranowanego
84%
PL
Poprzez rozwinięcie logarytmicznego potencjału wektorowego w szereg Fouriera wyznaczono pole magnetyczne generowane przez prąd w wewnętrznym niewspółosiowym ekranowanym przewodzie fazowym jako funkcję dwóch zmiennych r oraz ? walcowego układu współrzędnych. Wykorzystując rozwiązanie na gęstość prądu indukowanego przez to pole w ekranie określono składowe całkowitego pola magnetycznego. Wykazano przy tym, że pole to jest polem eliptycznym, którego moduł jest równy długości dłuższej półosi elipsy. Zbadano wpływ ekranu na rozkład tego pola w ekranie oraz na jego powierzchni wewnętrznej i zewnętrznej poprzez porównanie jego modułu z modułem pola wytworzonego przez przewód fazowy. Stwierdzono, że przewodząca osłona nie jest tzw. ekranem otwartym dla niewspółosiowego przewodu fazowego i wykazano, że wewnętrzne zjawisko zbliżenia w realizowanych w praktyce torach wielkoprądowych powinno być uwzględniane także dla częstotliwości przemysłowej.
EN
By the expansion of logarithmic vector potential into Fourier's series the magnetic field generated by current in internal non-coaxial screened phase conductor, which is a function depending on variable r and ? cylindrical coordinates was calculated. The equation which describes current density induced in the screen lets calculate all components of total magnetic field. And moreover, it was demonstrated that this field is elliptical, which modulus is equal to the length of ellipse semi-major axis. This paper shows how the screen influences onto distribution of this field into screen, and his internal and external surface. It was made by comparison of modulus of this field with modulus of magnetic field of phase conductor. It was found out that conducting screen is not so-called open screen for non-coaxial phase conductor and was demonstrated that proximity effect in produced at present high current busducts should be take into account for industrial frequency, too.
17
Content available remote Evaluations of Iron-based Material Expressed by Magnetic Transfer Function
67%
EN
We have been investigated a basic concept of material constant evaluation using transformer type probes in an a.c. field range between 20Hz and 200kHz. The probes are consisted of 2 transformers with open magnetic poles attached to the material surface under estimation and attached to the reference material, respectively. The output voltage of each transformer is connected in series and reverse to cancel the offset voltage caused by the leakage flux. The analyses are performed by using a.c. magnetic resistance theory of magnetic circuit. We attained the high sensitivity of conductivity and permeability changes in the material without direct contact as that in d.c. measurements. The transfer function of material in general was defined by the experimental results of the excitation current of the probe, operation frequency and the output voltages, independent of the characteristics of the transformer materials.
PL
Badano koncepcję stałej materiałowej przy badaniu próbki transformatorowej w pasmie 20 Hz do 200 kHz. Próbka składała się z dwóch otwartych transformatorów, z których jeden przyłożony był doi badanego materiału a drugi do materiału porównawczego. Wyjścia połączono szeregowo i przeciwsobnie. Określono funkcję przetwarzania umożliwiającą ocenę badanego materiału.
18
Content available remote Mathematical model of the electromagnetic accelerator
67%
EN
The model of the electromagnetic accelerator is offered as a solenoid with ferromagnetic core. The mathematical model is formed on the basis of the unique magnetic flux without dividing into a basic flux and leakage flux. The mathematical model of accelerator is formed in the coordinates of contour magnetic fluxes and currents of branches as a system differentially eventual equations.
PL
Analizowano model przyśpieszeniomierza elektromagnetycznego w postaci solenoid z rdzeniem ferromagnetycznym. Analizowano strumień magnetyczny bez podziału na strumień cewki i strumień rozproszony.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.