Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 10

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Polybrominated diphenyl ethers (PBDEs) are additive flame retardants which have found applications in polymers for many consumer plastic and electronic goods. Wide use of these chemicals has led to their extremely high concentrations in the indor environments. This paper presents an exploratory study of the photodebromination of five individual lower polybrominated diphenyl ether congeners (BDE-28, BDE-47, BDE-99, BDE-100 and BDE-101) irradiated with white light and different UV (A, B, C) light ranges. The capability of photodegradation of lower PBDEs under room lights was proven by the debromination which occurred with various effectiveness for the selected PBDE congeners and depended of light source. Almost all PBDE congeners showed the greatest decay when exposed to UV-C, with the exception of BDE-100. The decay of irradiated congeners occurred rapidly during the first 5 min of experiment. The final degradation varied from 38% decay (BDE-28, UV-C) to 94% (BDE-47, UV-C). These findings can help in predicting PBDE behavior in indoors and also be useful in the design of PBDE remediation processes.
PL
Bakterie z rodzaju Legionella są uznawane za jedne z groźniejszych przenoszonych drogą wodną organizmów chorobotwórczych, które wywołują ciężkie schorzenia układu oddechowego. Celem niniejszej pracy była ocena jakości wody w budynku edukacyjnym na podstawie występowania bakterii z rodzaju Legionella oraz wartości parametrów fizyko-chemicznych wody zimnej i ciepłej wody użytkowej. Próbki wody zimnej i ciepłej wody użytkowej (c.w.u.) pobierano do badań z 10 punktów czerpalnych w trzech seriach pomiarowych w okresie pięciu miesięcy. W badanych próbkach analizowano podstawowe parametry fizyko-chemiczne jakości wody tj. pH, przewodnictwo, temperatura, twardość, zasadowość, zawartość węgla ogólnego i nieorganicznego, stężenie azotanów(V), chlorków i siarczanów a także stężenie wapnia, magnezu, żelaza, manganu i cynku. Metodą hodowlaną oznaczano bakterie z rodzaju Legionella. Jakość wody instalacyjnej nie budziła zastrzeżeń i spełniała kryteria zawarte w obowiązującym Rozporządzeniu Ministra Zdrowia (Dz.U. 2015, poz. 1989). Jedynie temperatura wody zasilającej i powrotnej w instalacji c.w.u. nie spełniała obowiązujących przepisów, gdyż była niższa niż wymagana. Spośród przeprowadzonych trzech serii badawczych na przestrzeni 5 miesięcy, bakterie z rodzaju Legionella zostały wykryte jedynie w trakcie serii nr 1 w 80% próbkach c.w.u. Stopień skolonizowania instalacji określono jako wysoki do bardzo wysokiego. W próbkach wody nie wykryto obecności najbardziej niebezpiecznej L. pneumophila sg 1. We wszystkich próbkach Legionella – pozytywnych wykryto szczepy oznaczane jako L. pneumophila sg 2–14. Wymagało to podjęcia działań naprawczych w postaci dezynfekcji termicznej instalacji. Jej skuteczność potwierdziły wyniki badań w kolejnych seriach nr 2 i 3.
EN
Legionella are known as one of the dangerous water-borne pathogens, causing severe respiratory tract infections. The aim of this study was to assess the installation water quality in an educational building located in Lublin on the basis of Legionella sp. concentration and physicochemical parameters of cold and hot installation water. Samples (n=60) of cold and hot water were collected for testing from the 10 tapping points during three surveys over a period of five months. The test samples were analyzed for the basic physicochemical parameters of the water quality such as pH, electrical conductivity, temperature, hardness, alkalinity, the total carbon content, the concentration of nitrates, chlorides and sulphates. Additionally, the concentration of calcium, magnesium, iron, manganese and zinc were examined. The presence of Legionella in water samples was measured according the standard methods. The quality of the analyzed water did not raise objections and met the criteria of the Ordinance of the Polish Ministry of Health (2015, pos.1989). The only parameter which did not comply with applicable regulations was the temperature of the supply water and return hot water – it was lower than required. Bacteria of the genus Legionella were detected only in the hot water samples from series 1 when the rate of colonization reached the level of 80%. Among the positive samples, 2 contained less than 1000 CFU/100 ml, 4 samples contained 1x103 to 1x104 CFU/100 ml, and 2 samples contained more than 1x104 CFU/100 ml. The maximum number of CFU in a sample was 1.8x104/100 ml. The most dangerous serogroup L. pneumophila sg 1 was not detected in any of the positive isolated samples. All Legionella – positive samples belonged to L. pneumophila sg 2–14. These findings necessitated a corrective action in the form of thermal disinfection system and its maintenance. Its effectiveness was confirmed by the results of the survey of 2 and 3.
PL
W pracy oceniono za pomocą systemu QIM wyróżniki sensoryczne 30 pstrągów tęczowych w czasie przechowywania chłodniczego przez 48 godz. Ponadto dokonano instrumentalnych pomiarów właściwości fizykochemicznych tkanki mięśniowej: pH, przewodności elektrycznej właściwej i barwy skóry (wg CIE L*a*b*). Indeks (QI) po uśmierceniu ryb oceniono na 0 pkt, po 24 godz. – 3 pkt, a po 48 godz. – 9 pkt. W tkance mięśniowej ryb stwierdzono istotny spadek pH (z 6,93 do 6,54) i wzrost przewodności elektrycznej właściwej (z 4,14 do 7,95 mS cmˉ¹). Instrumentalne pomiary właściwości fizykochemicznych potwierdziły zmianę świeżości określone indeksem (QIM), co wskazuje na praktyczne wykorzystanie tego wskaźnika dla ryb przechowywanych w warunkach chłodniczych w ocenianym okresie.
EN
The sensory characteristics of 30 rainbow trout during chilling storage for 48 hours using QIM system were evaluated. In addition, instrumental measurements of muscle intrinsic properties, i.e. value of pH and electrical conductivity, and color of skin (according to CIE L*a*b*) were determined. Quality Index (QI) after fish killing amounted 0 pts., after 24 h 3 pts., and after 48 h 9 pts. The significant pH decrease (from 6.93 to 6.54), and an electrical conductivity increase (from 4.14 to 7.95 mS cmˉ¹) in fish muscle tissue were found. Instrumental measurements of intrinsic properties which confirmed the change of freshness specified by QIM method, indicate the practical use of this index for fish stored in chilling conditions during evaluated period.
PL
Badania przeprowadzono w pomieszczeniach przeznaczonych na czasowy pobyt ludzi: w pokojach biurowych i punktach kserograficznych zlokalizowanych na terenie miasta Lublina. Badania stężenia ozonu w powietrzu wewnętrznym przeprowadzone zostały w dwóch okresach: w okresie letnim i w sezonie grzewczym. Próbki do badań pobierano metodą pasywną. Pomiaru stężenia ozonu dokonano metodą spektrofotometryczną. Stężenia ozonu dla okresu letniego wyniosły: 0,01 -K),04 mg/m3 dla pomieszczeń biurowych oraz 0,008+0,176 mg/m3 dla punktów kserograficznych. Natomiast w sezonie grzewczym stężenia ozonu kształtowały się w następujących przedziałach: 0,007+0,018 mg/m3 dla pomieszczeń biurowych i 0,001-K),015 mg/m3 dla punktów kserograficznych. W punktach kserograficznych dopuszczalne stężenie 0,15 mg/m3 zostało przekroczone w sezonie letnim w dwóch przypadkach. W sezonie grzewczym nie odnotowano przekroczenia dopuszczalnego stężenia w punktach kserograficznych. W przypadku pomieszczeń biurowych dopuszczalne stężenie wynoszące 0,15 mg/m3 nie zostało przekroczone.
EN
Ozone is the common component of indoor air. Because of its high reactivity it plays an important role in forming of indoor air quality, which influence directly on health of interior occupants. It is a well-known fact, that ozone can damage the respiratory system, inflames and irritates respiratory tissues, and can worsen asthmatic symptoms in individuals with asthma. Ozone exposure can produce symptoms such as coughing, chest tightness and impaired breathing. Elevated exposures have the potential to induce permanent lung damage, and even increase the risk of premature death in persons with poor health. Hence, there is a need to measure the concentrations of ozone in indoor air environments. The indoor ozone concentration depends on the outdoor ozone concentrations, the rate at which indoor air is exchanged with outdoor air, interior air circulation, indoor sources of ozone (eg ozone generators, electrostatic air cleaners, photocopiers, and laser printers), the rate at which ozone is removed by indoor surfaces, and reactions between ozone and other chemicals in the air. The objective of this study was to examine ozone concentrations in indoor air in selected non-occupational environments: office rooms and Xerox service points. Summer time and cold (heating) season was examined. Samples were collected using passive method. The ozone concentration on summer time was within the range of 0.04-K).01 mg/m3 for office rooms and 0.008-0.176 mg/m3 for Xerox points. In two examined Xerox places the permitted level of ozone (0.15 mg/m3) was exceeded in summer time. In cold time the permitted level of ozone was not exceeded in any Xerox points. hi offices rooms the permitted level of ozone was not achieved.
PL
W pracy jest przedstawiona charakterystyka mikrobiologiczna próbek kurzu zebranych w pomieszczeniach mieszkalnych i placówkach edukacyjnych zlokalizowanych na obszarze miasta Lublina. W kurzu najczęściej spotykanymi bakteriami były pałeczki Gram-dodatnie. Większość należała do rodzaju Bacillus. W próbkach kurzu z placówek edukacyjnych największą koncentrację bakterii stanowił gatunek Bacillus subtillis. Największą grupę po pałeczkach Gram-dodatnich spotykanych w kurzu były ziarniaki Gram-dodatnie. Głównie był to rodzaj Micrococcus, a dominującym gatunkiem był Micrococcus luteus. W kurzu znajdywały się także Gram-dodatnie ziarniaki z rodzaju Staphylococcus oraz Gram-ujemne pałeczki. W przypadku grzybów zawartych w kurzu dominującymi rodzajami były Aspergillus (głównie gatunek Aspergillus nigerii) oraz Penicillium. Grzyb z rodzaju Cladosporium był także spotykany w badanych próbkach.
EN
Dust particles collected from indoor environments may contain hundreds of chemically and biologically active components, which can cause many adverse health effects and deterioration of building materials. While all types of microorganisms can cause problems indoors, bacteria and fungi are most commonly associated with indoor air quality complaints. Some of them produce mucus and excrete chemicals which can provoke allergy, respiratory system and skin irritation, headache, or fatigue. This study was designed to obtain information about characterization of the microbial community in settled dust samples from indoor environments of the Lublin area. Dust samples were collected from households and educational establishments. Microbial species and their concentrations were determined by culture analysis. The concentrations and proportions of morphologically distinguishable culturable bacteria and fungi in dust samples was as follows. In case of bacteria the most commonly found were Gram-positive rods, predominantly Bacillus spp. (Bacillus subtillis) and cocci - genus Micrococcus (Micrococcus leutus) and Staphylococcus. Fungi were represented by genus Aspergillus (mainly Aspergillus nigerii), Penicillium, and Cladosporium. Additionally, microbial concentrations of similar environments vary between sample types, eg total amount of fungi has been higher in dust from textile covered floor than in samples from bare floor.
PL
Dostępne badania literaturowe wskazują, że kurz domowy może być zapadliskiem dla wielu niebezpiecznych substancji chemicznych występujących w powietrzu wewnętrznym, np. średniolotnych związków organicznych (perfluorowanych, bromoorganicznych antypirenów, pestycydów, wielopierścieniowych węglowodorów aromatycznych), materii organicznej oraz metali, których pochodzenie może mieć charakter naturalny lub związany z działalnością człowieka. Kurz domowy może być szczególnie ważnym źródłem zatruć metalami ciężkimi wśród małych dzieci, które mimowolnie spożywają go w trakcie zabaw. W pracy przedstawiono charakterystykę potencjalnych źródeł metali ciężkich: Cd, Co, Cr, Cu, Ni, Pb, Zn i ich poziomów w kurzu domowym, zebranym w 30 lubelskich mieszkaniach.
EN
Many studies have reported that household dust serves as a sink to hazardous substances including semivolatile organic compounds (perfluorinated compounds, brominated flame retardants, pesticides, PAHs), organic matter, and metals of both natural and man-made origin. Metal pollution in indoor dust, in particular heavy metals has been investigated from years in order to moderate elevation in children’s blood an the unintentional ingestion of indoor dust. Generally, contamination of indoor dust by metals can be a result of industrial activity, automobile emission and other indoor sources, eg paints, devices etc. This study pays attention to the potential sources and levels of selected heavy metals distributed in the households of the Lublin area, Poland, The highest concentrations from investigated metals have been found for Zn, Cu, Cr, Pb and Ni, respectively.
EN
For many years formaldehyde has been known as a major eye irritant in indoor environment. It is not only one of the most common indoor air contaminants, but also the most common aldehyde detected in office and residential indoor air. Its concentration in office spaces at the Lublin University of Technology, Poland, was measured. It appeared that formaldehyde was detected in all the samples collected and its concentration ranged from 14.4 to 56žg/m3. Concentration of this gas in rooms with carpeting was lower than in those with wood-based panels. Higher aldehyde concentration was found in the rooms painted a few months before the experiment.
EN
Levels and distribution of selected polybrominated diphenyl ether congeners in dust samples taken from different indoor environments in Lublin, South-Eastem Poland, are reported. The most abundant congeners, found in the majority of sampling sites, were BDE 47, 100 and 28, respectively. The highest levels of examined congeners were observed in dust samples taken from a computer repair facility and labs. BDE 47. 99 and 100, occurring at highest levels and having the greatest contribution confirm that in Polish indoor environments polymer products contain Penta -BDE technical mixture.
EN
An increasing interest of noteworthy problem of bromoorganic compounds sources, releases and transformation in the environment can be observed in recent years. The concern is related in particular to brominated flame retardants (BFRs) - especially polybrominated diphenyl ethers (PBDEs), and polybrominated dibenzo-p-dioxins and polybrominated dibenzofurans (PBDD/Fs). This problem is not recognized in Poland. Hence, the attempt to estimate the significance of the threat under the Polish conditions appears to be justified. Due to the numerous similarities to earlier examined chlorinated analogues of these chemicals (in physical, chemical properties and influence to living creatures), brominated pollutants can compose new group of important environmental contaminants.
PL
W ostatnich latach można zaobserwować wzrost zainteresowania źródłami, emisją i przemianami w środowisku przyrodniczym związków bromoorganicznych. Szczególnie dużo uwagi poświęca się zagadnieniu bromowych antypirenów i polibromowanych dibenzo-p-dioksyn i polibromowanych dibenzofuranów (PBDD/Fs). W Polsce problem ten nie jest jeszcze rozpoznany. Podjęcie próby określenia potencjalnego zagrożenia ze strony tych substancji wydaje się jednak być uzasadnione. Zważywszy na liczne podobieństwa do wcześniej zbadanych analogów chlorowych, zarówno we właściwościach fizykochemicznych, a także oddziaływaniu na organizmy żywe, PBDD/Fs mogą stanowić nową grupę silnych trucizn środowiskowych.
EN
Polybrominated dibenzo-p-dioxins (PBDDs) and polybrominated dibenzofurans (PBDFs) are classified as one of the most powerfull influencing groups of environmental pollutants. Despite the fact that PBDD/Fs have never been commercially manufactured (except for HpBF) they are widespread in nature, although occur in lower concentration as chlorinated dioxins and furans. The main sources of PBDD/Fs in the environment, called “primary” are the chemical, photochemical and thermal processes. Release of PBDD/Fs from the primary sources lead the further contamination of the environment from the secondary sources - reservoirs. Among important potential sources of PBDD/Fs there are processes of waste utilization.
PL
Polibromowane dibenzo-p-dioksyny (PBDDs) i polibromowane dibenzofurany (PBDFs) są zaliczane do grupy najsilniej działających trucizn środowiskowych. Pomimo że PBDD/Fs nigdy nie były celowo produkowane przez człowieka (z wyjątkiem HpBDF) są związkami szeroko rozpowszechnionymi w środowisku przyrodniczym. Za główne źródła polibromowanych dioksyn i furanów w środowisku, określane jako pierwotne, przyjmuje się procesy chemiczne, termiczne i fotochemiczne związane z działalnością człowieka. Wyróżnia się także źródła wtórne, tzw. „rezerwuary” dioksyn, czyli elementy przyrody, gdzie związki zostały zgromadzone wskutek działania procesów pierwotnych. Wśród ważnych potencjalnych źródeł PBDD/Fs należy wskazać procesy utylizacji odpadów.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.