EN
Precise current measurements are essential part of modern motor control algorithms. They are also required in switch mode power converters, safety circuits, current sources, supervisor systems and many other applications. In order to select the right method, it is often required from the designer to have wide knowledge of the appropriate integrated circuit, its parameters and applications. Still increasing requirements for the speed and precision of designing solutions, decreasing voltage levels, power consumption and aspects of EMC compatibility impose often contrary initial conditions.
PL
Precyzyjne pomiary prądu są zasadniczą częścią nowoczesnych algorytmów sterowania silnikami. Są także stosowane w przetwornicach mocy, obwodach bezpieczeństwa, źródłach prądowych, systemach nadzoru i wielu innych aplikacjach. W celu wybrania właściwej metody projektant musi mieć szeroką wiedzę na temat odpowiedniego obwodu scalonego, jego parametrów i aplikacji. Rosnące wymagania dotyczące szybkości i precyzji projektowanych rozwiązań, obniżenie poziomów napięć, zużycie energii oraz aspekty kompatybilności elektromagnetycznej powodują często sprzeczne warunki początkowe.
PL
W artykule przedstawiono strukturę rozbudowanego, dwukanałowego wzmacniacza pomiarowego (bufora) o podwyższonych parametrach metrologicznych w paśmie częstotliwości akustycznych. Wzmacniacz jest elementem systemu pomiarowego, w którym pełni rolę stopnia dopasowującego napięcia pływające do niesymetrycznego wejścia układu pomiarowego. Przedstawiono wyniki badań eksperymentalnych wybranych stopni wzmacniacza.
EN
The paper presents an extended structure of two-channel instrumentation amplifier (IA). The IA has higher metrological parameters relating to typical-setup of an instrumentation amplifier (Fig. 2) in the audio frequency range. The IA is intended for use in a measurement system to calibrate low-value alternating-current standard resistors at audio frequencies. In the developed system a resistor RX is directly compared with a standard resistor RN (Fig. 1). The impedance ratio ZX/ZN of the resistors is determined from the measurement of the voltage ratio UX/UN. The measurement of floating voltages by a digitizer with grounded inputs requires IA (buffers) (B1, B2). Due to the assumptions concerning the system being developed, buffers should be characterized by a relatively high input impedance and small errors of the transformer voltage ratio over a frequency bandwidth from 40 Hz to 10 kHz. Block diagram of the IA is shown in Fig 3. The IA consist: two input buffers (BW1, BW2), input stage (SW) with floating ground (PM), difference amplifier (SR) and circuit for common mode voltage adjustment (KWNW). Figs. 4, 5, 6, 7 show a simplified schematic diagrams of the individual IA stages. In Figs. 8 and 9 the frequency characteristics of the module and phase error of the input buffer (BW1) voltage ratio are shown. The frequency characteristics of the input buffer BW2 are almost the same. In Fig. 10 the frequency characteristics of CMRR prior to adjustment and following the adjustment the real part of the CMR are shown.
EN
This paper presents the design of a chopper stabilized current mode instrumentation amplifier and analyzes the performance limitations imposed by chopping technique in detail. The amplifier targets to be the read out circuitry of a high precision temperature sensor. Since the required bandwidth in this kind of applications is very low, nested chopping technique is used to provide continuous offset reduction and eliminate 1/f noise. The amplifier is designed in 0.18 μm CMOS process. The resulting input referred noise is 20 nV/√ Hz, the offset is 582 nV and the CMRR exceeds 110 dB. The power consumption of the total design is 420 μW.
PL
W pracy przedstawiono piezorezystywne mikromechaniczne przetworniki siły oraz zmian masy wykonane technologiami mikroelektronicznymi. Przedstawiona została ich zasada działania, główne źródła szumów występujących w tego rodzaju elementach oraz konstrukcja wzmacniacza do pomiaru szumów występujących w prezentowanych układach mikromechanicznych. Zaprezentowano także sposób doboru wzmacniaczy operacyjnych ze względu na poziom szumu występującego w systemie pomiarowym.
EN
In this paper we present micromechanical force and mass change transducer with integrated piezoresistive deflection sensor made with use of microelectronic technology. We present the principles of operation of these transducers and identified the main sources of noise that occur in this type of elements. Amplifier design is presented for the measurement of low-frequency noise and selection method of operational amplifiers because of the noise present in the measurement system.
PL
W artykule zaprezentowano nową koncepcję układu rejestracji sygnałów bioelektrycznych. W prezentowanym systemie akwizycji sygnałów wykorzystano nowy, programowalny uniwersalny moduł przetwarzania ADS1298 firmy Texas Instruments zawierający wejściowe multipleksery, wzmacniacze o programowanym wzmocnieniu, 24 bitowe przetworniki A/C i układ interfejsu szeregowego. Prezentowany system umożliwia rejestrację sygnałów wraz ze składową stałą, co pozwoliło na wyeliminowanie powszechnie stosowanych filtrów górno-przepustowych o dużych stałych czasowych. Prezentowany moduł może znaleźć zastosowanie w aplikacjach biomedycznych do rejestracji różnorodnych sygnałów bioelektrycznych np. sygnału elektrokardiograficznego (EKG), elektrogastrograficznego (EGG) czy sygnału elektroencefalograficznego (EEG).
EN
In this paper a new application of the universal programmable ECG front-end module ADS1298 is presented. To avoid amplification of the input signal dc component in standard biomedical amplifiers after the first stage, an analog high-pass filter is used. Hardware high-pass filters are difficult to change their corner frequency (time constant) and a step change of the dc offset voltage gives a long transient response. This long response saturates the next amplifier and causes decay of the signal for a certain time. Analysis of such a case, given in this work, allows estimating the dead time as a function of some amplifier parameters like distribution of the amplifier gain before and after the high-pass filter, the filter time constant, supply voltages of the first amplifier , the input signal range of an A/D converter and the zoom factor p used in a visuali-zation system. Thanks to the 24-bits resolution of the A/D converter and programmable gain input amplifiers, a biomedical signal can be recorded with its offset, which allows eliminating hardware high-pass filters. High-pass filtering is realised by software, which allows building more flexible systems using the same analog front-end. The proposed solution was tested on simulated signals form generators, ECG phantom and 12 leads ECG signal with good results. It allows constructing portable, universal biomedical recording systems such as 12 leads ECG systems, Holter recorders, EEG recorders EEG recorders, tuned only by software.
PL
W artykule przedstawiono interaktywny system sterowania pracą laboratoryjnej suwnicy pomostowej natorowej wykorzystujący wzmacniacz pomiarowy firmy Hottinger Baldwin Messtechnik Spider8. Do sterowania pracą elektronapędów z przemiennikami częstotliwości wykorzystano wejścia i wyjścia cyfrowe wzmacniacza, natomiast wejścia analogowe wykorzystano do monitorowania wybranych obciążeń suwnicy pomostowej natorowej. Do wizualizacji, rejestracji wielkości mierzonych oraz sterowania i demonstracji stanu elektronapędów suwnicy pomostowej wykorzystano program Catman.
EN
The paper presents an interactive system for controlling the operation of the laboratory bridge crane using a measurement amplifier of the Hottinger Baldwin Messtechnik Company - SPIDER8. To control the operation of electric drives with frequency converters digital input and output of this amplifier were used. Analog inputs were used to monitor selected loads of bridge crane. For visualization, registration and control of the measured values as well as demonstration of the electric drive of bridge crane the Catman program was used.
PL
W artykule zaprezentowano nową koncepcję układu do rejestracji sygnałów bioelektrycznych polegającą na zastosowaniu wzmacniacza prądu stałego i 24 bitowego przetwornika A/C. W zbudowanym systemie wykorzystano nowy układ ADS1298 firmy Texas Instruments, zawierający 8 torów pomiarowych. Przedstawiony system umożliwia wielokanałową rejestrację sygnałów wraz ze składową stałą. Pozwoliło to na wyeliminowanie, powszechnie dotąd stosowanych, filtrów górno-przepustowych o dużych stałych czasowych i zastąpienie ich filtrami cyfrowymi.
EN
The new concept of biomedical recording device using DC-coupled amplifier and 24 bit A/D converter is presented. Using recently launched front-end module ADS1298 from Texas-Instruments 8 channels system was designed. Thanks to 24–bits resolution of A/D converter and programmable gain input amplifiers, biomedical signals can be recorded with offsets, that allows to eliminate hardware high-pass filters.
PL
Artykuł prezentuje zastosowanie metody Monte Carlo do porównawczych badań symulacyjnych własności metrologicznych różnych struktur przetworników pomiarowych. Metoda umożliwia określenie wartości błędu granicznego struktury wynikającego z tolerancji użytych podzespołów i w konsekwencji wytypowanie struktury o mniejszej wrażliwości.
EN
This paper presents the application of Monte Carlo method for investigation of sensitivity to component tolerance of different structures of instrumentation converters. Method makes it possible to determine limiting error of the structures, caused by passive elements tolerances. So it is possible to point out structure which is less sensible to component tolerance.
PL
Niedoskonałe właściowości dynamiczne wzmacniacza pomiarowego są przyczyną powstania znaczących błędów dynamicznych podczas pomiaru sygnałów odkształconych. W przyprowadzonych badaniach symulacyjnych zastosowano sygnał o kształcie zgodnym z przbiegiem prądu maszyny indukcyjnejzasilanej z falownika napięcia. Do korekcji błędów dynamicznych w czasie rzeczywistym wykorzystano układ dyskretny typu FIR. W układzie korekcyjnym zasymulowaano efekt obcinania najmniej znaczących bitów liczb reprezentujących część ułamkową zmiennych, w zależności od liczby bitów rejestru procesora przeznaczonych na zapis mantysy. Zbadano wpływ arytmetyki stałopozycyjnej i zmiennopozycyjnej na dokładność korekcji błędów dynamicznych wnoszonych przez wzmacniacz pomiarowy dla różnych wartości jego stałej czasowej. Oceniono również dokładność koreklcji dla różnych szybkości zmian mierzonego sygnału.
EN
Weak dynamics features of the instrumentation amplifier are the source of considerable dynamic errors during measurement of the nonsinusoidal signals. The current of the inverter fed induction drive has been taken under consideration during simulations. A real-time algorithm of these errors correction has been examined with respect to the variable representation in the processor registers. Fixed-point and floating- point arithmetic have been emulated for various bit nymbers of fraction representation. The algorithm acts as a scalar product of two wectors. The first one consist of the measured signal. Precision of the correction algorithm has been examined for various time constant of the amplifier and various slopes of the signal.
PL
W artykule rozpatrzono wrażliwość wzmacniaczy pomiarowych na zakłócenia wielkiej częstotliwości. Przedstawiono wyniki badań odporności znanych typów wzmacniaczy oraz podano sposoby podwyższenia tej odporności za pomocą dodatkowych elementów zewnętrznych.
EN
Influence of zero-level instability of the input amplifiers, caused by external high-frequency noise are described. High-frequency noise signals, generated mainly by broad casting and TV transmitters, are common in the measurements circuits environments. In non-linear amplifier input circuits, detection of those signals causes instability of zero-level. Analytic description of those phenomena is very complicated and does not guide to significant quantitative results. Choice of the best suited types of input amplifiers should be made on the base of the experimental investigations. Results of the measurements of the high-frequency noise immunity of the most common type of input amplifiers, used in measurement circuits, are given in the paper.