Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 18

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  water hardness
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Even if granular media filtration effectively reduces the turbidity of water, its limited surface functionalities and physical properties may constrain its ability to effectively remove critical contaminants from water. In our research, we successfully synthesized a new type of porous material – multiple coated GO/sand (M-GO/S) by integrating ordinary river sand with graphite oxide (GO) for the adsorptive removal of calcium ions in terms of water softening. Prior investigations confirmed it could remove water turbidity and fluoride simultaneously. M-GO/S was characterized using microscopic and spectroscopic techniques. The results indicate the presence of an uneven coating of graphite oxide, and the nanocomposite contains oxygencontaining functional groups. Under given conditions, the M-GO/S nanocomposite demonstrated remarkable efficacy in removing 75% of calcium ions (a higher removal percentage than commercial coal powdered activated carbon) from simulated hard water: pH 8, 5.0 g dosage, 50 mg/L calcium ions, and 20 min contact time. The isotherm and kinetic data revealed that the adsorption mechanism primarily comprises multilayer adsorption by means of a chemical sorption process. The mechanism of the proposed M-GO/S nanocomposite for removing calcium ions from hard water is elucidated using (XPS) analysis. The presence of (-O-Ca-O-) chemical bonds on the surface of the nanocomposite after equilibration with calcium ions suggests the occurrence of chemical interactions between the calcium ions and oxygen-containing functional groups of the M-GO/S. Consequently, the synthesized M-GO/S nanocomposite can be identified as a promising candidate for hard water treatment.
EN
Water hardness, taste, smell, and color are the most important tap water parameters for consumers. Microbiological and physicochemical parameters of tap water should not exceed the permissible values listed in Regulation of Ministry of Health on the quality of water intended for human consumption. Tap water parameters are regularly monitored, however periodically, deviations are allowed, which make it possible to supply water that does not meet the requirements of quality standards. Such a situation causes that consumers have doubts about the health safety of the supplied water. The organoleptic properties of the water such as taste, smell and color can be easily improved at home using jug filters. In this study, we tested the effectiveness of eight inexpensive and easily available jug water filters to soften and remove chlorine from water. Filters were labeled with symbols A, B, C, D, E, F, G, H. Experiments were performed with model water, which was prepared from drinking water taken directly from a sink and spiked with hypochlorite sodium. The hardness of model water was 7.5 mval/L, while free chlorine concentration was equaled 1.1 mg/L. 200 L of model water was filtered by each filter in duplicates. It was found that jug filtration is an effective method for removal of chlorine from water, provided that a use of proper filter. Although, all used filters are dedicated to removal of chlorine from water, not all of them represented a sufficient removal of chlorine. Filters A, B and C were the most effective for chlorine removal. For these filters, chlorine concentration was reduced to the value of 0.075 mg/L. Moreover, for filters A, B, C and E, the concentration of chlorine in the filtrates remained relatively similar throughout the entire experiment. Filters D and H represented the poorest efficiency of chlorine removal. Concentration of chlorine in these filtrates exceeded permissible value recommended by Regulation of Ministry of Health. Among eight studied filters (i.e. 0.3 mg/L), filters A and B are considered as the most effective for water softening. Generally, the efficiency of jug filtration in water softening was at mediocre level and decrease in time. It could have been caused by the high initial hardness of tap water in Gliwice. In the case of very hard water, more often than recommended by the manufacturers replacing the filter cartridges is recommended.
EN
Water is one of the humans’ basic needs that are essential in daily lives. The water use related to the production of the food processing industry must at least meet the quality standards required for drinking water. The Production process water is obtained from the artesian well that has been treated with a physical treatment process. The microbiological examination result of total Coliform is 8.6 MPN/100 ml meaning that it does not meet the quality standard requirements, which is 0 MPN/100 ml (The Minister of Health Regulation Number 492 of 2010, concerning Drinking Water Quality Requirements), it is necessary to treat the production process water using a Melt Blown Filter (MBF) and UV-C rays. The purpose of this study was to determine the differences in the variation of the 1, 3, and 5-micron of Melt Blown Filter cartridge 10” in reducing the amount of total Coliform, as well as the water hardness and their effect on disinfection using UV-C rays. The type of research used is experimental research with a pretest-posttest without control research design. There is a reduction in the average total Coliform after the treatment using a Melt Blown Filter, with a result of 1, 3, and 5-micron as 2.95 MPN /100ml, 3.61 MPB/100 ml, and 7.31 MPN/100 ml with a percentage reduction of 100%, 94.5%, and 82.4%, respectively. The average total Coliform using the Melt Blown Filter equipped with the UV-C rays treatment resulted in a reduction of 1, 3, and 5-micron as 2.95 MPN/100 ml, 3.95 MPN/100 ml, 8.88 MPN/100 ml respectively, with a reduction percentage of 100%, for each treatment. The data analysis for total coliform using the One-Way ANOVA test resulted in a pvalue of 0.001, the effective variation obtained is 1-micron MBF equipped with UV-C rays. The analysis of results pertaining to the water hardness data showed that the use of Melt Blown Filter could not reduce water hardness, but the UV-C rays could still be used accordingly. The data analysis for water hardness was performed using KruskalWallis with a p-value of 0.820, meaning that there are no differences in Melt Blown Filter variation on the results of total water hardness value.
EN
The laboratory tests presented in the article aimed at determining the influence of water hardness on the effectiveness of humic substances removal in the coagulation process. The tests were conducted on three model solutions; very soft water, soft water and semi-hard water. The concentration of humic substances in each solution was equal to 20 mg/dm3. Calcium hydroxide, ferric(III)chloride and aluminium sulphate(VI) were applied as coagulants. On the basis of the conducted tests, it was found that the increased content of calcium, and particularly of magnesium in water, improves the effectiveness of humic substances removal. The process effectiveness expressed by changes in colour and permanganate index was the highest for semi-hard water. A decrease in colour equal to 88.8% and in permanganate index – 72.1% was observed in this case for the largest dose of calcium. Even better results were obtained by applying the remaining coagulants; a decrease in colour amounted to 99%, and in permanganate index to 95%.
PL
W pracy omówiono znaczenie zdrowotne wysokich i bardzo wysokich poziomów twardości wody przeznaczonej do spożycia przez ludzi. Szkodliwe następstwa dla zdrowia, obejmujące wzrost ryzyka kamicy nerkowej i atopowego zapalenia skóry u dzieci bywają wiązane jedynie z bardzo wysokimi wartościami twardości wody, przekraczającymi 500 mg/l.
EN
The paper discusses the health significance of high and very high hardness levels of water intended for human consumption. Harmful health consequences, including increased risk of nephrolithiasis and atopic dermatitis in children, are associated only with very high water hardness values, exceeding 500 mg/l.
7
Content available remote Zmiany twardości wody na linii zakład uzdatniania wody – krakowscy odbiorcy
PL
Każdy z nas pewnie wielokrotnie zastanawiał się nad jakością wody, którą spożywamy. Czy faktycznie jej skład jest identyczny czy może tylko zbliżony do składu wody oczyszczonej przez Zakład Uzdatniania Wody? Czy transport wody przez rurociągi ma wpływ na zmianę zawartości poszczególnych pierwiastków? W tym artykule poruszono ten problem i porównano twardość wody bezpośrednio po wszystkich etapach uzdatniania, a także tej która jest nam dostarczana do kranów. Zbadano także twardość wody pitnej przed i po użyciu domowego filtra dzbankowego, który stał się bardzo popularny w ostatnich czasach. Zmierzono zawartość jonów magnezu oraz wapnia wykorzystując do badań metodę ASA, technikę płomieniową.
EN
Each of us probably repeatedly considers the quality of water we drink. Does its composition really correspond to the composition of water purified by the Water Treatment Plant? Does transporting water through pipelines affect the change in the content of particular elements? This article addresses this issue and compares the hardness of water directly after all stages of the treatment, and water that is delivered to the tap. The hardness of drinking water was also examined before and after using a household jug filter, which has become very popular in recent times. Manufacturers of such filters guarantee better quality and taste of consumed water. The magnesium and calcium ions were measured using Atomic Absorption Spectrometry (FAAS).
EN
The paper presents laboratory experiments on the influence of different hardness water samples collected from the municipal water supply system on the intensification of leaching pollutants from the internal cement mortar pipe lining to drinking water. The paper presents the analysis of water quality indices, such as pH, aluminum and selected heavy metals concentrations after contacting with cement coatings.
PL
W artykule przestawiono wyniki badań laboratoryjnych opisujących wpływ wód pobranych z miejskiej sieci wodociągowej, charakteryzujących się odmiennymi twardościami, na stopień przenikania do nich zanieczyszczeń z wewnętrznych powłok cementowych. Niniejsze opracowanie obejmuje analizę wskaźników jakości wody, takich jak pH, stężenie glinu oraz stężenie wybranych metali ciężkich na skutek jej kontaktu z powłokami cementowymi.
EN
In this paper, the hardness water parameter has been used to presentation spatial interpolation algorithm. Those analyses were carried out based on the results of water quality database from the Chief Sanitary Inspection for the Silesian Province (2012–2014). Only the points which have been assigned the value of water hardness below the 60 [mg/l] and above 400 [mg/l] were selected. These points can be sensitive to loss health safety of drinking water in supply system. Making above mentioned analysis allows to limit the number of water quality control points from 1500 to 150 for Silesia Province. The analysis showed clearly that the use of GIS in procedures of selecting monitoring points allow to reduce the cost of controls on both the official control and internal control carried out by water company.
PL
W artykule, do prezentacji algorytmu interpolacji przestrzennej wykorzystano wartości parametru twardość wody. Przeprowadzone analizy oparto na wynikach jakości wody pochodzących z baz danych Głównego Inspektora Sanitarnego dla województwa śląskiego (2012–2014). W analizach wyselekcjonowano tylko te punkty, o przypisanych wartościach granicznych, dla których stężenie parametru wskaźnikowego przyjmowało wartość poniżej 60 [mg/l] i wyższą niż 400 [mg/l]. Tak wyselekcjonowane punkty mogą być wrażliwe na utratę bezpieczeństwa wody. Przeprowadzenie tych analiz dla województwa śląskiego umożliwia znaczne ograniczenie ilości punktów kontroli jakości wody z ponad 1500 do ok 150. Analiza wykazała jednoznacznie, iż wykorzystanie GIS w typowaniu punktów monitoringu umożliwia obniżenie kosztów kontroli zarówno po stronie urzędowej jak i przedsiębiorstwa wodociągowego.
EN
Decomposition kinetics of natural organic substances during the photocatalytic process with a semi-conductor TiO2 has been investigated. In the study, a laboratory reactor Heraeus and in a photocatalytic membrane reactor were used. Simulated solutions of deionized water, surface water and fulvic acids, differing in composition, were tested in the experiment. In order to determine reaction rate constants, the Langmuir–Hinshelwood kinetic model based on the first order reaction was applied. It was found that photocatalytic process enabled effective degradation of natural organic substances although its run was affected by inorganic ions, mainly those producing water hardness, present in water.
PL
Twardość wody jest jednym z najbardziej zauważalnych przez odbiorców wskaźników jakości wody. Niejednokrotnie w praktyce eksploatacyjnej spotykamy się z tym, iż świetnie odżelaziona czy odmanganiona, ale twarda woda jest źle postrzegana przez odbiorców. Normy wskazują na maksymalną zawartość twardości w okolicach 500 mg/l - jednak optymalna z użytkowego punktu widzenia twardość wody, która z jednej strony wiąże się z zawartością wapnia i magnezu, a z drugiej z niską uciążliwością eksploatacji sprzętów domowych to ok. 200-250 mgCaC03/l.
PL
W pracy badano stopień odtworzenia mleka z odtłuszczonego proszku mlecznego w naparze kawowym w zależności od temperatury, twardości i mocy naparu. Stwierdzono, że wygląd mleka odtworzonego z proszku, zwilżalność, rozpraszalność, wskaźnik nierozpuszczalności i test kawowy zależały w większym stopniu od temperatury niż mocy i twardości naparu kawowego.
EN
An influence of reconstitution level of milk from skim milk powder in coffee infusion on temperature, intensity and hardness of coffee infusion was examined. It was found that milk appearance, wettability, dispersibility, insolubility index and coffee test depended in greater degree on temperature than coffee infusion intensity and water hardness.
PL
W pracy badano wpływ temperatury i twardości wody na stopień odtworzenia mleka z rozpyłowego odtłuszczonego proszku mlecznego. Stwierdzono, że wygląd mleka po rekonstytucji proszku, zwilżalność, rozpraszalność i wskaźnik nierozpuszczalności zależały w większym stopniu od temperatury niż twardości wody.
EN
An influence of temperature and water hardness on the reconstitution stage of skim milk powder was examined. It was found that milk appearance, wettability, dispersibility and index insolubility depended rather on the temperature than on hardness of water.
PL
W pracy badano stopień odtworzenia mleka z pełnego proszku mlecznego w naparze kawowym w zależności od temperatury, twardości i mocy naparu. Stwierdzono, że wygląd mleka odtworzonego z proszku, zwilżalność, rozpraszalność, wskaźnik nierozpuszczalności i test kawowy zależały w większym stopniu od temperatury niż mocy i twardości naparu kawowego.
EN
The reconstitution stage of whole milk powder in coffee infusion as a dependence of temperaturę and hardness of water was examined. It was found that milk appearance, wettability, dispersibility, index insolubility and coffee test depended morę on temperaturę than on intensity of coffee infusion and hardness of water.
PL
W pracy przedstawiono wpływ soli wywołujących twardość wody na zjawisko redukcji oporów przy przepływie wodnych roztworów chlorku heksadecylotrimetyloamoniowego (HTAC) i salicylanu sodu (NaSal). Zaobserwowano, że układ HTAC/NaSal jest stosunkowo odporny na obecność chlorku wapnia i chlorku magnezu, podczas gdy dodatek chlorku żelaza (III) może prowadzić do zaniku redukcji oporów przepływu.
EN
An influence of salts caused water hardness on the drag reduction phenomenon in flow of hexadecyltrimethylammonium chloride (HTAC) and sodium salicylate (NaSal) aqueous solutions is presented in the paper. It was observed that the HTAC/NaSal system was relatively resistant to magnesium and calcium salts presence while the addition of ferric chloride caused decay of drag reduction.
PL
W pracy badano wpływ temperatury i twardości wody na stopień odtworzenia mleka z rozpyłowego proszku mlecznego. Stwierdzono, że wygląd mleka po rekonstytucji proszku, zwilżalność, rozpraszalność i wskaźnik nierozpuszczalności zależały w większym stopniu od temperatury niż twardości wody.
EN
An influence of temperaturę and water hardness on the reconstitution stage of whole milk powder was examined. It was found that milk appearance, wettability, dispersibility and index insolubility depen-ded morę on temperaturę than on hardness of water.
17
Content available remote Electrokinetic Study of Water Hardness during Acid Dyeing with Silk
EN
In this paper, the effect of water hardness, expressed in CaCO3, on the dyeing of silk with acid dye under acid, alkaline and isoelectric point dyeing conditions was studied using the zeta potential method. Under acidic conditions and in the presence of calcium ion, the positive zeta potential of silk was found to decrease with a reduction in dye adsorption. Such a phenomenon might be due to the presence of cation which increased the dyeing potential barrier at the interface between fibre and dye solution. This would result in a higher resistance of dye anions passing through the interface. Under alkaline conditions the zeta potential of silk was negative and resulted in a strong potential barrier against the dye anions. The presence of calcium ions would result in a decrease in the absolute value of the zeta potential of silk fibre, with an overall increase in dye absorption. At the isoelectric point, the zeta potential of the silk fibre was found to be near zero, and the dye adsorption was not influenced by the cations. These results showed that calcium ions could have a strong electrolytic effect on dyeing, even at very low concentrations.
PL
Badano wpływ twardości wody, wyrażonej w CaCO3, na barwienie jedwabiu barwnikami kwasowymi w obecności kwasu i zasady oraz izoelektryczny punkt barwienia używając metody potencjałów. W środowisku kwaśnym i w obecności jonów wapnia, dodatni potencjał zeta jedwabiu spadał wraz z redukcją barwnika. Zjawisko to może mieć związek z obecnością kationów, które zwiększają próg energetyczny reakcji na granicy faz między włóknem a roztworem barwnika. To może powodować wyższą rezystancję dla anionów barwnika przechodzących przez granicę faz. W środowisku alkalicznym potencjał zeta jedwabiu był ujemny i powodował wysoki próg energetyczny w stosunku do anionów barwnika. Obecność jonów wapnia może powodować spadek całkowitej wartości potencjału zeta włókien jedwabiu, w ogólnym wzroście w poborze barwnika. W punkcie izoelektrycznym potencjał zeta włókien jedwabiu znajduje się blisko zera, a kationy nie mają wpływu na absorpcję barwnika. Wyniki te pokazują, że jony wapnia mogą mieć istotny elektrokinetyczny wpływ na barwienie, nawet w małym stężeniu.
PL
W pracy przeprowadzono badania kinetyki wiązania dwutlenku węgla podczas filtracji wody przez złoże dolomitu częściowo zdekarbonizowanego w temperaturach 750 st.C, 800 st.C i 850 st.C. Wykazano, że reaktywność dolomitu z dwutlenkiem węgla rośnie wraz ze wzrostem pH i maleje wraz ze wzrostem prędkości filtracji. Udział wapnia i magnezu w twardości ogólnej wody zależy od warunków prażenia dolomitu. W wodzie przefiltrowanej przez złoże dolomitu, w którym węglan magnezu był częściowo zdekarbonizowany (temp. prażenia 750 st.C i 850 st.C) dominowała twardość wapniowa, natomiast w przypadku dolomitu prażonego w temp. 800st.C uzyskano zawartość związków wapnia i magnezu zbliżoną do równomolowej. Stwierdzono, że kinetyka reakcji składników złoża z dwutlenkiem węgla ograniczona jest stanem równowagi węglanowo-wapniowej w wypadku rozpuszczania węglanu wapnia oraz wysoką reaktywnością tlenku magnezu, zależną tylko od dawki dwutlenku węgla.
EN
Kinetic studies were carried out on the fixation of carbon dioxide in the course of water filtration through a slaked dolomite bed at 750 oC, 800 oC and 850 oC. The reactivity of dolomite with carbon dioxide was found to rise with the increasing pH and decrease with higher filtration rate. The contribution of calcium and magnesium to total water hardness depends on the slaking conditions. The water that had been filtered through a dolomite bed where magnesium carbonate was slaked (slaking temperature, 750 oC and 850 oC) showed predominantly calcium hardness. When dolomite was slaked at 800 oC, the content of calcium and magnesium compounds approached the equimolar one. The kinetics of the reaction of the bed components with carbon dioxide was found to be limited by the state of carbonate-calcium equilibrium in the case of calcium carbonate solubilization and by the high reactivity of magnesium oxide, which depends on the carbon dioxide dose alone.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.