Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 11

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  volumetric mass transfer coefficient
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The main objective of these experiments was to study the oxygen mass transfer rate through the volumetric mass transfer coefficient (kLa) for an experimental set-up equipped with a rotating magnetic field (RMF) generator and various liquids. The experimental results indicated that kLa increased along the magnetic strength and the superficial gas velocity. Mathematical correlations defining the influence of the considered factors on kLa were proposed.
2
Content available Wymiana masy w barbotażowych kolumnach pulsacyjnych
PL
Przedstawiono wyniki badań współczynnika wnikania masy w pulsacyjnej kolumnie barbotażowej o przekroju kwadratowym o boku D = 0,135 m i wysokości całkowitej H = 2,25 m. Zastosowanie pulsacji cieczy w kolumnie barbotażowej powoduje znaczną intensyfikację procesów wymiany masy. Zaprezentowano wpływ wartości kolejnych częstotliwości rezonansowych pulsacji na wartość współczynnika wnikania masy dla kolumn o smukłości H/D < 10.
EN
Results of studies on mass transfer coefficient in a glass pulsed bubble column of square section with the side D = 0.135 m and height H = 2.25 m are presented in the paper. Application of pulsation to a bubble column caused intensification of mass transfer processes. The influence of resonant frequencies on a value of volumetric mass transfer coefficient for a column with the slenderness H/D < 10 is presented.
PL
Przedstawiono wyniki analizy wpływu skali aparatu (średnicy mieszalnika) na wartość współczynnika wnikania masy kLa (proces transportu tlenu między gazem a cieczą). W oparciu o szeroki zbiór danych: dwa mieszalniki różniące się 10-krotnie objętością roboczą, trzy mieszadła oraz sześć wartości strumienia gazu określono wpływ średnicy mieszalnika na kLa, przy stałej pozornej prędkości gazu wog albo parametru vvm (określającego strumień gazu liczony w m3/min. odniesiony do m3 cieczy). Opracowano zależność do obliczania współczynnika kLa w układzie ciecz-gaz.
EN
The analysis results of the effect of agitated vessel scale (its diameter) on the volumetric mass transfer coefficient (gas – liquid mass transfer process) are presented in this paper. A wide range of data: two agitated vessels differ ten times in working liquid volume, three agitators and six volumetric gas flow rates, enabled one to determine the diameter effect on kLa, assuming a constant value of superficial gas velocity, wog, or vvm parameter (describing gas flow rate in m3/min per m3 of liquid phase). The correlations for kLa calculation were elaborated.
PL
W pracy przedstawiono wyniki analizy eksperymentalnej procesu transportu masy między gazem a cieczą w obecności fazy stałej, w mieszalniku o objętości roboczej równej 0,2 m3. Na postawie badań określono wpływ parametrów operacyjnych, stężenia elektrolitu oraz typu mieszadła na wartość współczynnika wnikania masy. Mieszadła TR oraz CD 6 okazały się najkorzystniejsze do prowadzenia procesu transportu masy. Dla każdego z mieszadeł zaproponowano równania do obliczania współczynnika kLa.
EN
The experimental analysis of gas-liquid mass transfer process in the presence of solid phase conducted in an agitated vessel of working volume VL = 0.2 m3 is presented in this paper. An effect of operating parameters, electrolyte concentration and agitator type on the volumetric mass transfer coefficient was determined. For non-coalescing system better results w obtained using RT or CD 6 turbines compared to A 315 one. The correlations were proposed for each type of agitator to predict the volumetric mass transfer coefficient.
PL
W pracy przedstawiono wyniki analizy eksperymentalnej procesu wymiany masy w mieszalniku dużej skali (VL = 0,2 m3), w układach ciecz - gaz Próżnej zdolności do koalescencji. W oparciu o wyniki badań objętościowego współczynnika wnikania masy, określono wpływ: parametrów operacyjnych, rodzaju cieczy oraz typu mieszadła na wartość tego współczynnika. Najkorzystniejsze do prowadzenia procesu wymiany masy w zbiorniku dużej skali okazały się mieszadła TR oraz CD 6. Dla każdego z układów zaproponowano równania do obliczania współczynnika kLa.
EN
Experimental analysis of gas-liquid mass transfer process conducted in a laboratory large-scale agitated vessel (working volume: VL = 0.2 m3) is presented in this paper. Analysis was based on research results dealing with the volumetric mass transfer coefficient. Measurements were carried out in coalescing and non-coalescing systems. For both systems better results were obtained using RT or CD 6 turbines. Correlations for the calculation of volumetric mass transfer coefficient for each system are proposed.
PL
W prezentowanej pracy przedstawiono dyskusję wpływu wirującego pola magnetycznego na uzyskiwane objętościowe współczynniki wnikania masy lą a dla różnego typu cicczy (ścieki, woda kranowa, sztuczny ściek). Uzyskane rezultaty zostały przedstawione w formie zależności analitycznych uwzględniających zmienność współczynnika kLa oraz wskaźnika a od parametrów procesowych.
EN
In this paper, the results of the experimental studies concerning the volumetric mass transfer coefficient kLa obtained for gas-liquid systems are discussed. The influence of the rotating magnetic field on the aeration process of the various types of liquids (wastewater, tap water, synthetic wastewater) are presented. The obtained results of the volumetric mass transfer coefficients are described by using the analytical relationships as the function of the operational parameters. Moreover, the aeration process under the action of the rotating magnetic field is quantified by means of the α-factor.
EN
The aim of experimental studies was to investigate mass transfer process in a gas - liquid system agitated using two impellers. The volumetric gas — liquid mass transfer coefficients ku, were measured tor two systems of high-speed impellers (Kushton turbine - A 315 and Rushton turbine - Smith turbine) operating in a tall vessel of diameter equal to D = 0.288 m. The k Lo, coefficient was determined by the dynamic method.
PL
Celem pracy była analiza eksperymentalna procesu wymiany masy w układzie ciecz-gaz mieszanym w zbiorniku z dwoma mieszadłami na wspólnym wale. Pomiary przeprowadzono w zbiorniku o średnicy D = 0.288 m. dla dwóch konfiguracji mieszadeł. W obu jako górne stosowano mieszadło turbinowe Riishlona. a jako dolne turbinowe Smilha lub A 315. Pomiary współczynnika ku, przeprowadzono metodą dynamiczna.
EN
The process of continuous production of dissolved oxygen free water was investigated by means of desorption of dissolved oxygen into nitrogen micro-bubbles, which were generated in a new motionless mixer named Ramond Supermixer. The pressure drop across the mixer and the volumetric mass transfer coefficient during the desorption of oxygen from water were measured for various combinations of process variables, liquid and gas velocities and a number of mixing units with the aim to derive the respective correlations.
EN
Measurement results of the volumetric mass transfer coefficient in water and model sewage during aeration with a self-aspiration disk impeller of diameter d = 125 mm are presented in the paper. It was showed that the optimum impeller work did not depend on ions presence in the solution.
PL
W pracy zaproponowano zmodyfikowane stanowisko do pomiarów lokalnych wartości objętościowego współczynnika wnikania masy kLa metodą dynamiczną. Przeanalizowano poszczególne elementy stanowiska pod względem identyfikacji parametrów wpływających na jakość pomiarów. Przeprowadzono analizę współczynnika kja dla układu woda - powietrze przy zastosowaniu tarczowego mieszadła samozasysającego o średnicy dm = 125 mm.
EN
A modified set-up for measuring local values of the volumetric mass transfer coefficient, ki.a, by a dynamic method was proposed. The particular elements of set-up were analysed with respect to identification of parameters influencing the measurement quality. Local values of the ki.a coefficient for the water-air system were analysed using a self-aspirating disk impeller of diameter dm — 125 mm.
EN
The investigations dealing with the mass transfer enhancement in gas-liquid-liquid systems are summarized and discussed. The effect of an immiscible liquid phase, in which a gag component is more soluble than in the continuous phase, on the volumetric liquid phase mass transfer coefficient was particularly examined. Additionally, same results obtained by the authors on carbon dioxide absorption into different two-phase liquid systems are presented.
PL
Podsumowano i omówiono prezentowane w literaturze wyniki prac doświadczalnych dotyczących szybkości absorpcji w układach gaz-ciecz-ciecz. Otrzymane własne wyniki oraz badania innych autorów wskazują, że większa pojemność absorpcyjna fazy rozproszonej w stosunku do fazy ciągłej nie jest warunkiem wystarczającym, który zapewnia wzrost szybkości absorpcji w układzie ciecz-ciecz. Nie ma jakościowej i ilościowej zgodności co do oceny wpływu drobno rozproszonej drugiej fazy ciekłej na przyspieszenie procesu wnikania masy. Analizę wyników innych autorów utrudniają rozbieżności w interpretacji uzyskanych danych doświadczalnych. Dotyczą one przede wszystkim różnic w metodzie wyznaczania objętościowego współczynnika wnikania masy dla składnika gazowego do fazy ciekłej oraz czynnika przyspieszenia. Dla znacznej części badanych układów zaobserwowano wzrost szybkości absorpcji w stosunku do szybkości w wodzie lub wodnym roztworze, szczególnie dla małych zawartości cieczy organicznej. Takie same wnioski wypływają z analizy własnych badań w dwufazowych układach benzen-woda, n-dodekan-woda i toluen-woda. Wydaje się, że decydujący wpływ na efekt przyspieszenia absorpcji w układzie gaz-ciecz-ciecz ma inny mechanizm ruchu masy niż w układzie gaz-ciecz. Szybkość absorpcji zależy od wielu własności fizykochemicznych układu ciecz-ciecz, w tym lepkości cieczy i napięcia powierzchniowego na granicy faz, rozmiaru kropli fazy rozproszonej i warunków hydrodynamicznych. Wyjaśnienie mechanizmu ruchu masy w układach gaz-ciecz-ciecz wymaga dalszych prac doświadczalnych obejmujących badania innych substancji organicznych o różnych pojemnościach absorpcyjnych oraz uwzględnienie w analizie konieczności pomiaru rozmiaru kropli.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.