Prolonged exposure to elevated temperatures exceeding 47°C, which can occur during root canal obturation, can cause damage of both dental and bone tissues. In order to study the temperature distribution on the surface of the tooth root a temperature measuring device with cold-junction compensation is proposed. For in vitro measurement of the temperature distribution on the surface of the tooth, 8 thermocouples placed in direct contact with the cementum of the tooth were used. In order to eliminate the cold-junction temperature variations, the temperature equilibration device and RTD were used. The suggested linear approximation for the thermocouples' conversion function provides a nonlinearity relative error of less than 0.05% for K-type thermocouples and 0.07% for J-type thermocouples over the temperature range from 20 to 60°C.
PL
Długotrwała ekspozycja na podwyższone temperatury przekraczające 47°C, które mogą wystąpić podczas wypełniania kanałów korzeniowych, może spowodować uszkodzenie zarówno tkanek zęba, jak i kości. W celu zbadania rozkładu temperatury na powierzchni korzenia zęba zaproponowano urządzenie do pomiaru temperatury z kompensacją zimnego złącza. Do pomiaru in vitro rozkładu temperatury na powierzchni zęba wykorzystano 8 termopar umieszczonych w bezpośrednim kontakcie z cementem zęba. W celu wyeliminowania wahania temperatury zimnego złącza zastosowano urządzenie do wyrównania temperatur oraz czujnik rezystancyjny RTD. Proponowana aproksymacja liniowa funkcji przetwarzania termopary zapewnia względny błąd nieliniowości mniejszy niż 0,05% dla termopar typu K i 0,07% dla termopar typu J w zakresie temperatur od 20 do 60°C.
EN
The aim of the work was to perform experimental tests for thermal analysis on the outer surface of the radiator. For this purpose, a localized test stand was used in one of the lecture rooms in Kielce University of Technology. The experiment concerned the isothermal character of a radiator during its operation. Temperature distribution was verified with two different methods: thermocouples and thermovision camera. The radiator was divided into 8 measuring fields and temperature was measured in each of them. The experiments were conducted for different supply flow rates of the medium. The results were presented by means of diagrams comparing both methods of temperature survey.
3
Content available Thermoelectric heat exchanger
EN
The article presents a heat exchanger with thermoelectric generators, which consists of two single sheet heat exchangers, between which thermoelectric generators are placed. The heat exchanger in question is used to convert waste heat energy into DC electricity. The construction of the heat exchanger is described in detail in the article, and the study of temperature distribution of both the high and the low temperature side is presented. The basic parameters of the heat exchanger are also given. They were determined with the current-voltage characteristics method, and then they were compared with the values established in the conventional way.
PL
W artykule przedstawiono wymiennik ciepła z termogeneratorami, który składa się z dwóch pojedynczych płytowych wymienników wymiennika ciepła, pomiędzy którymi umieszczone są termogeneratory. Wymiennik służy do przetwarzania energii cieplnej w energię elektryczną prądu stałego. Przedstawiono konstrukcję wymiennika oraz badania rozkładu temperatury stron o wysokiej i niskiej temperaturze. Opisano podstawowe parametry wymiennika, wyznaczone metodą charakterystyki prądowo-napięciowej. Porównano je z wartościami wyznaczonymi w klasyczny sposób.
PL
W artykule autor dokonał ogólnego przeglądu prac [1-7], w których brał udział, opisujących nieinwazyjne układy detekcji przemieszczania frontów spalania w ładunkach stałych materiałów wybuchowych - paliw rakietowych i mieszanin pirotechnicznych - spalających się papierosowo (zw. ładunkami typu „end-burning”) w przelotowych, rurowych komorach spalania. Układy te służą przede wszystkim do określania liniowej szybkości spalania badanych ładunków wybuchowych. Autorskie układy detekcji obejmowały zastosowanie grafitu pirolitycznego (pirografitu) jako materiału konstrukcyjnego i sensorycznego komór spalania oraz jednego z urządzeń detekcji ruchu frontu spalania, tj. kamery IR albo VIS albo termopar. Przeglądu dokonano na tle innych układów detekcji frontów spalania stałych materiałów wybuchowych, wykorzystujących detektory optyczne [8-12] lub termopary [13-21].
EN
In this contribution author did a general overview of works [1-7], in which he participated, describing non-invasive systems on detection of movement of combustion fronts in solid end-burning explosive materials – rocket propellants and pyrotechnic compositions - inserted into tube combustion chambers. The systems are used to measure linear burning velocity of tested explosives. Detecting systems, the author has contributed to as well, concerned the application of pyrolitic graphite (pyrographite) as structural and sensory material of combustive chambers and one of devices detecting the displacement of the burning front i.e. an IR or VIS camera or thermocouples. The review has been made in the background of other systems using optical detectors [8-12] or thermocouples [13-21].
PL
Badania dotyczące termoelementów Au/Pt, pomimo dość długiego okresu ich stosowania w metrologii, wciąż nie są wystarczająco rozwinięte, aby można zamknąć rozdział dotyczący tej grupy przyrządów pomiarowych. Ich właściwości pozwalają myśleć nad jeszcze szerszym zastosowaniem, m.in. jako termometru interpolacyjnego. Pod tym kątem prowadzone były prace w ramach grantu Researcher Mobility Grant (RMG) w projekcie badawczym JRP SIB10 NOTED (Novel techniques for traceable temperature dissemination). W artykule omówiono prace, prowadzone w Centro Español de Metrología (CEM), dotyczące pomiarów niejednorodności termoelementów Au/Pt oraz ich wzorcowanie w punktach stałych Międzynarodowej Skali Temperatury (MST-90).
EN
Studies on Au versus Pt thermocouples are still not sufficiently developed, despite the fact of already fairly long use in metrology. It makes impossible to close the chapter on this group of measuring instruments. Properties of Au versus Pt thermocouples allow to think on a much wider use, including a interpolation thermometer. From this point of view, work in a research project SIB10 noted JRP (Novel techniques for dissemination traceable temperature) was carried out under a grant Researcher Mobility Grant (RMG). The article describes the work carried out at the Centro Español de Metrología (CEM) concerning the measurements of Au versus Pt thermocouples homogeneity and calibration in fixed points of the International Temperature Scale (ITS-90).
PL
: Mierniki i rejestratory bez czujników (wskaźniki) i symulatory temperatury przeznaczone do współpracy z czujnikami termoelektrycznymi wzorcowane są z niepewnościami rozszerzonymi dla k = 2 rzędu tysięcznych części kelwina. W laboratoriach akredytowanych wzorcowania takiego dokonuje się na podstawie zaleceń instrukcji EURAMETu [7]. W artykule przedstawiono beziteracyjną metodę eliminacji błędu wyznaczenia odwrotnej charakterystyki termometrycznej znormalizowanych czujników termoelektrycznych.
EN
The paper presents the influence of thermoelectric inverse characteristics on the calibration uncertainty of measuring instruments used with thermocouples. Calibration methods for temperature indicators and simulators recommended by EURAMET for use in accredited laboratories are described in the guide [7]. Table 1 presents frequently used thermocouples. Equations (1-4) for the standards thermocouples are illustrated in Fig. 1 (the Seebeck coefficient) and Fig. 2 (change of the Seebeck coefficient). The calculation error of inverse polynomials (4) for thermocouples made of noble metals is shown in Fig. 3 and those made of non-noble metals in Fig. 4. Section 4 describes the uncertainty calculation method for calibration of electrical temperature measuring instruments and simulators. In Section 5 the authors describe how to calculate the temperature value from a thermoelectric voltage without using iterative methods in the case of standardized thermocouples.
EN
This work presents a new, non-invasive method for the discrete detection of combustion zone propagation in high energy materials – pyrotechnic compositions – by means of thermocouples bonded to the external, side surface of a pyrolytic graphite (pyrographite) tube filled with the pyrotechnic composition and ignited at the one end by a CO2 laser. The thermocouples were positioned in a line parallel to the longitudinal axis of the pyrographite tube, which was used as a directional heat guide (thermal management) and a thermoresistant structure, enabling detection of the propagation of the combustion zone as a heat zone generated by the combustion, traveling on the outside surface of the pyrographite tube along its axis. Such a directional heat guidance was caused by the unique thermal conductivity anisotropy of pyrographite resulting in low thermal conductivity of the pyrographite tube along its axis and high thermal conductivity across the tube radius. The thermocouples detected passages of the outside heat zone that were equally time delayed in relation to the combustion zone inside the tube. Dividing the distance between the thermocouples by the time between their thermoelectric response to the same (corresponding) isotherm of the heat zone, gave the average burning rate of the high energy composition being tested over the distance between the thermocouples. The proposed procedure for burning rate determination was verified by numerical simulations.
PL
Mierniki temperatury współpracujące z czujnikami termoelektrycznymi najlepiej wzorcować wraz z całym torem pomiarowym. Nie zawsze jest to jednak możliwe, np. ze względu na trwałe przymocowanie czujnika lub częstą konieczność jego wymiany. W artykule przedstawiono sposób postępowania w takiej sytuacji oraz występujące wtedy błędy pomiaru ze szczególnym wskazaniem na wpływ przewodów kompensacyjnych i spoiny odniesienia.
EN
Indicators intended for use with thermocouples best to calibrate with complete measuring chain. This is not always possible, however because of e.g. the permanent connection of the sensor or the necessity for frequent sensor replacement. This paper presents procedures in such situation and measurement errors occurring then with particular reference to the impact of extension cables and cold junction.
PL
Mikrogeneratory termoelektryczne mogą być stosowane do zasilania układów mikroelektronicznych lub mikrosystemów. W artykule przedstawiono proces wytwarzania takiego generatora. Zastosowano technologię grubowarstwową w połączeniu z techniką LTCC. Do wytworzenia miniaturowych, gęsto upakowanych termopar wykorzystano sitodruk precyzyjny, jak również technikę past fotodefiniowalnych. Termopary wykonano na niewypalonych podłożach LTCC (green tape) łącząc je szeregowo pod względem elektrycznym - tworząc termostos. Następne kilkanaście takich podłoży złożono razem tworząc stos ("struktura "kanapkowa") i wykonano elektryczne połączenia między termoparami. W ten sposób powstał wielowarstwowy stos termoelektryczny. Rezultatem prac była budowa małego generatora składającego się z kilkuset termopar.
EN
Thermoelectric microgenerator can be used for supplying microsystems or microelectronic circuits. In the paper fabrication process of such generator is presented. Thick film technology combined with LTCC technique was applied. Precise screen-printing as well as photoimageable inks technique was used to fabricate narrow, densely disposed thermocouples onto the unfired LTCC substrates. The thermocouples were connected electrically in series to form the thermopile. After that a number of substrates were put together to form a stack (the "sandwich"), and the thermopiles printed on particular LTCC tapes were connected together to form a multilayer thermoelectric stack. As a result small generators consisted of few hundreds of thermocouples were fabricated.
10
Content available remote Cold-junction temperature compensation of thermoelectric transducers
EN
In this paper, the properties of temperature-dependent bridge-type circuits employed for the cold-junction compensation – for the bridge circuits excitation from separate constant voltage or constant current source – are discussed. The considerations have been focused on the techniques of improving the effectiveness of the compensating circuits. It has been found that over a narrow range of the cold-junction temperature variations the effectiveness of the compensation circuit can be improved by the shift of the circuit characteristic; across a wide range of the temperature variations the improvement in the effectiveness of the compensation circuit can be achieved by using a temperature-dependent constant voltage source which has positive temperature coefficient. The proposed compensating circuit allows reducing the absolute compensation error to less than 0.1°C for different types of thermocouples.
PL
Przeanalizowano właściwości układów mostkowych zależnych od temperatury, służących do kompensacji temperatury spoiny odniesienia termopary z oddzielnymi źródłami napięcia lub prądu. Wykazano, że dla wąskiego zakresu zmian temperatury spoiny odniesienia można osiągnąć poprawę efektywności układów kompensacyjnych za pomocą przesunięcia charakterystyk tych układów, natomiast dla szerokiego zakresu zmian temperatury można osiągnąć poprawę efektywności układów kompensacyjnych wykorzystując źródło napięcia zależne od temperatury, wykazujące dodatni współczynnik temperaturowy. Proponowany układ pozwala osiągnąć zmniejszenie błędu bezwzględnego kompensacji do wartości nie przekraczających 0,1°C dla różnych typów termopar.
PL
Obciążenia temperaturą obiektów inżynierskich wywołują siły wewnętrzne niekiedy znacznie większe niż inne obciążenia działające na konstrukcję. Czynnikami decydującymi o ich wielkości jest między innymi różnica temperatur pomiędzy zewnętrznymi płaszczyznami analizowanego elementu oraz rozkład temperatur po grubości elementu. W niniejszej pracy przedstawiono próbę pomiarów tychże parametrów przy zastosowaniu termopar płaszczowych.
EN
Temperature load of engineering constructions is caused by internal forces which are sometimes bigger than the other loads. The temperature gradient between outer surfaces of analysed element and temperature distribution influence the value of the loads. The paper presents the proposal of measurements of the temperature gradient and temperature distribution with the use of thermocouples.