Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 33

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  prosthesis
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
The continued development of microprocessor-based knee prostheses has improved the independence of people with a femoral amputation in many environments. This study aimed to describe the effect of slopes on kinematic joint variables and segmental asymmetry.
EN
This paper presents a procedure for developing a components of the hand prosthesis using reverse engineering. The hand model was obtained using a plaster cast and a 3D scanner. The 3D model of the prosthesis was remodelled using selected CAD software. The prosthesis was made of MED610 polymer material using PolyJet Matrix (PJM) technology. The MED610 material was chosen for its biocompatible properties. The printed model of the finger prosthesis was subjected to a bending test.
PL
W artykule przedstawiono procedurę projektowania elementów protezy dłoni z wykorzystaniem inżynierii odwrotnej. Modele dłoni odwzorowano w postaci odlewów gipsowych. Korzystając ze skanera 3D otrzymano chmurę punktów, którą przekonwertowano do pliku STL. Model 3D protezy przebudowano w oprogramowaniu CAD. Protezę wykonano z materiału polimerowego MED610 z zastosowaniem technologii PolyJet Matrix (PJM). Materiał MED610 został wybrany ze względu na biokompatybilne właściwości. Wydrukowany model protezy poddano próbie zginania.
EN
This study examines the possibility of implementing intelligent artificial limbs for patients after injuries or amputations. Brain-computer technology allows signals to be acquired and sent between the brain and an external device. Upper limb prostheses, however, are quite a complicated tool, because the hand itself has a very complex structure and consists of several joints. The most complicated joint is undoubtedly the saddle joint, which is located at the base of the thumb. You need to demonstrate adequate anatomical knowledge to construct a prosthesis that will be easy to use and resemble a human hand as much as possible. It is also important to create the right control system with the right software that will easily work together with the brain-computer interface. Therefore, the proposed solution in this work consists of three parts, which are: the Emotiv EPOC + Neuroheadsets, a control system made of a servo and an Arduino UNO board (with dedicated software), and a hand prosthesis model made in the three-dimensional graphic program Blender and printed using a 3D printer. Such a hand prosthesis controlled by a signal from the brain could help people with disabilities after amputations and people who have damaged innervation at the stump site.
EN
The paper presents the experimental process of manufacturing individualized prosthetic sockets out of thermoplas‑ tic material, using an additive manufacturing technology of Fused Deposition Modelling. The patient was an adult male with an amputated forearm. His stump was 3D scanned using a low‑cost 3D scanner in a semi‑automated manner. Then, the anthropometric data was used for the creation of a model of a prosthetic socket, which was subsequently manufactured. Three different 3D printers were used, with three different materials (ABS, nylon and PC) and three different sets of process parameters. The paper contains the descriptions of the process, its results and opinions by the patient, leading to the selection of an optimal process course variant.
EN
The subject of the article is the evaluation of the strength of revision implants made of titanium or tantalum alloy, used during bone reconstruction of a hip joint while potentially using additional stabilizing screws, necessary due to significant bone loss. The article provides a preliminary strength analysis of implants, indispensable for further evaluation of strength limitations due to the risk of implant damage depending on the structure and number of additional screw holes. In the human locomotor system, the hip joint is the joint with the most load, hence the main problem is to establish an adequate load model which ought to be assumed for the needs of implant strength analysis. It is found necessary to perform a short, analytical review of the existing hip joint load models from the point of view of choosing the proper one, considering evaluation of implant strength by means of numerical studies using FEM. Differences in the implant load distribution depending on the used material are shown.
PL
Narząd wzroku jest jednym z najważniejszych zmysłów u człowieka warunkującym odbieranie ponad 90% bodźców zewnętrznych. Jego utrata lub uszkodzenie praktycznie eliminują człowieka ze społeczeństwa. Dotychczasowe próby naprawy czy też poprawy wzroku opierały się głównie na korekcji obrazu docierającego na siatkówkę. W przypadku uszkodzenia tej tkanki odbieranie światła jest niemożliwe. Najnowsze wyniki badań ukazują możliwości w zakresie wykonania protez tego narządu za pomocą układów fotoelektrycznych.
EN
The organ of sight is one of the most important senses in humans, conditioning the reception of over 90% of external stimuli. Its loss or damage virtually eliminates a man from society. Previous attempts to repair or improve eyesight were based mainly on the correction of the image reaching the retina. In the case of damage to this tissue, it is impossible to receive light.The latest research results show the possibilities in the field of prostheses prosthesis using photoelectric systems.
PL
Narząd wzroku jest jednym z najważniejszych zmysłów u człowieka warunkującym odbieranie ponad 90% bodźców zewnętrznych. Jego utrata lub uszkodzenie praktycznie eliminują człowieka ze społeczeństwa. Dotychczasowe próby naprawy czy też poprawy wzroku opierały się głównie na korekcji obrazu docierającego na siatkówkę. W przypadku uszkodzenia tej tkanki odbieranie światła jest niemożliwe. Najnowsze wyniki badań ukazują możliwości w zakresie wykonania protez tego narządu za pomocą układów fotoelektrycznych.
EN
The organ of sight is one of the most important senses in humans, conditioning the reception of over 90% of external stimuli. Its loss or damage virtually eliminates a man from society. Previous attempts to repair or improve eyesight were based mainly on the correction of the image reaching the retina. In the case of damage to this tissue, it is impossible to receive light. The latest research results show the possibilities in the field of prosthesis using photoelectric systems.
PL
Narząd wzroku jest jednym z najważniejszych zmysłów człowieka warunkującym odbieranie ponad 90% bodźców zewnętrznych. Jego utrata lub uszkodzenie praktycznie eliminują człowieka ze społeczeństwa. Dotychczasowe próby naprawy czy też poprawy wzroku opierały się głównie na korekcji obrazu docierającego na siatkówkę. W przypadku uszkodzenia tej tkanki odbieranie światła jest niemożliwe. Najnowsze wyniki badań ukazują możliwości w zakresie wykonania protez tego narządu za pomocą układów fotoelektrycznych.
EN
The organ of sight is one of the most important senses in humans, conditioning the reception of over 90% of external stimuli. Its loss or damage virtually eliminates a man from society. Previous attempts to repair or improve eyesight were based mainly on the correction of the image reaching the retina. In the case of damage to this tissue, it is impossible to receive light. The latest research results show the possibilities in the field of prosthesis using photoelectric systems.
PL
W pracy przedstawiono porównanie stóp dwunożnych robotów kroczących i stóp protezowych w zakresie rozwiązań konstrukcyjnych, napędowych i elementów tłumiących oraz biomechaniki chodu. Analiza porównawcza wskazuje, że obydwie konstrukcje zbliżają się do siebie starając się odtworzyć naturalny sposób poruszania się człowieka, a wzajemne wykorzystanie sprawdzonych rozwiązań przyczyni się do budowy protez lepiej odpowiadających wymaganiom pacjentów oraz robotów poruszających się w sposób zbliżony do ludzkiego.
EN
The paper presents a comparison of two-legged walking robots and prosthetic feet in the field of construction, drive and damping solutions as well as biomechanics of walking. Comparative analysis depicts that both constructions are approaching each other trying to recreate the natural way of human movement, and the mutual use of proven solutions will contribute to the construction of prostheses better suited to the requirements of patients and robots moving in a manner similar to human.
EN
This study focuses on a three-dimensional numerical analysis by the finite element method, the mechanical behavior of the dental prosthesis implant composed of a single implant. The effect of the nature of food on the level and distribution of the Von Mises equivalent stress generated in the bone and the elements that constitute this prosthesis have been highlighted. It has been shown that this level is particularly important that the Crushed masticated foods are rigid. This work was carried out to answer questions whose purpose was to analyze the risk of overload in the mandibular region. Loads transfer mechanisms and the possible failure of osseointegrated implants, the shape of the implant, the geometrical and mechanical properties of the placement site and bone resorption of the crest. A proper estimation of these effects allows the correct design of the implant.
PL
Celem pracy jest ocena planów leczenia VMAT i 3D dla modelowego przypadku obszaru tarczowego otaczającego tytanową protezę kości udowej. Plany zostały wykonane z użyciem systemu planowania Monaco na bazie badania CT nogi pacjenta z rozszerzonym zakresem liczb Hounsfielda i korekcją MAR. Gęstość tytanu została przypisana poprzez zastosowanie krzywej konwersji HU-ED. Porównanie planów pokazało, że plany VMAT charakteryzuje lepsza konformalność i niższe dawki średnie w obszarze nogi oraz mniejsza wrażliwość na niepewności centrowania wiązek. Zaletą planu 3D jest natomiast łatwość jego weryfikacji dozymetrycznej in-vivo.
EN
The aim of this study is to compare VMAT and 3D plans for a case of a target volume encompassing femur prosthesis made of titanium. The plans were created with Monaco treatment planning system based on CT scans of a patient leg performed in extended mode with a MAR correction. Electron density of titanium was assigned by HU-ED conversion curve. The study showed that VMAT plans were superior over 3D plan in respect to its conformity and average dose in leg. Also, VMAT plans were less sensitive to set-up errors. The advantage of the 3D plan is a facility for its in-vivo dosimetric verification.
13
Content available remote Planowanie radioterapii dla pacjentów z protezami. Cz. 1, Badania fantomowe
PL
W pracy omówiono specyficzne problemy jakie pojawiają się podczas przygotowania planów leczenia radioterapią dla pacjentów z protezami. Proponowane rozwiązania mają na celu minimalizowanie błędów dozymetrycznych, na jakie narażone są tego typu plany.
EN
The paper describes specific problems which we encounter preparing radiotherapy treatment plans for patients with prosthesis. The aim of proposed solutions is to minimise dosimetric errors of plans prepared in such cases.
EN
The aim of this study was a biomechanical evaluation of the stresses generated in bone during implantation of the implant designed for direct skeletal attachment of limb prosthesis and a typical interference-fit implant of the reference. Using the finite element method implantation processes of both implants were modelled. The influence of two factors on stresses generated in bone was analysed: first – the radial interference between the implant and reamed marrow cavity (0.05 mm up to 0.25 mm) and second – the three types of implant's surfaces: polished, beaded and flaked. Obtained results show that in the case of the smallest value of radial interference (0.05 mm), stresses generated in cortical bone are more appropriate for the reference implant than for the designed one. With the increase of both analysed factors generated stresses are in favour of the designed implant especially in longitudinal direction for both, implant-adjacent and deep cortical tissue (even 18 times lower) alike. Stresses patterns also present that stresses values are lower in overall volume of analysed bone's part, during implantation of the designed implant. Presented characteristics and patterns confirm that the implantation method of presented implant is safer than a method for typical interference-fit implants for direct skeletal attachment of limb prosthesis.
15
Content available Application of incremental sheet forming
EN
This paper describes some manufacturing aspects and an example of application of the Incremental Sheet Forming (ISF) technology which was used for production of the craniofacial prosthesis. The brief description of prosthesis designing was presented as well. The main topic of the paper is comparison of milling and ISF technologies for preparing the tools for prosthesis thermoforming.
PL
Choroba zwyrodnieniowa stawów biodrowych jest bardzo częstym i poważnym problemem zdrowotnym wśród osób powyżej 65. roku życia. W przypadku znacznego zaawansowania choroby i po wyczerpaniu możliwości leczenia zachowawczego przeprowadza się zabieg endoprotezoplastyki. Najpopularniejszym badaniem przed wszczepieniem i po wszczepieniu endoprotezy jest klasyczne RTG (Classic Roentgenodiagnostics) porównawcze stawów biodrowych. Ocena stanu po endoprotezoplastyce stawu biodrowego wymaga wykonania bardzo wysokiej jakości radiogramów. Zgodnie z filozofią optymalizacji w rentgenodiagnostyce należy dążyć do zapewnienia najwyższej wartości diagnostycznej przy jak najniższej dawce promieniowania. Celem badania była analiza, jak poszczególne elementy endoprotezy wpływają na EXI (Exposure Index) oraz dawkę DAP (Dose Area Product) w zmiennych warunkach ekspozycji. Przeanalizowano 108 radiogramów tytanowego trzpienia z głową (kobalt-chrom), panewki ceramicznej w metalowej czaszy oraz całej endoprotezy – złożenie wymienionych wcześniej elementów przy zmianie napięcia anodowego w zakresie 70-93 kV i trzech różnych wariantach użycia kratki przeciwrozproszeniowej (bez kratki, f (o) = 115 i f (o) = 180). Wartość EXI odpowiednio dla całej protezy, panewki ceramicznej wmetalowej czaszy i trzpienia z tytanu z głową kobaltowo-chromową maleje wraz ze zmianą kratki rozproszeniowej na kratkę o większym kącie geometrii paskówołowiowych (f (o) = 180). Rodzaj materiału poszczególnych elementów protezy wpływa na wartość DAP. Przy odległości FFD 115 cm, zastosowanie kratki przeciwrozproszeniowej f (o) = 180 zamiast f (o) = 115 powoduje wzrost wartości DAP przy ekspozycji całej endoprotezy.
EN
Osteoarthritis of hips is a very common and serious health problem among people over 65 years of age. In case of advanced disease, and after having exhausted the possibilities of conservative treatment, the surgery needs to be performed. The most common testing before and after implantation of the prosthesis is made by means of X-ray examination. Evaluation of total hip replacement requires a very good quality radiographs. According to the philosophy of optimizing, diagnostic radiology should strive to provide the highest diagnostic value at the lowest dose of radiation. The aim of the study was to analyze how different elements of the prosthesis affect the Exposure Index (EXI) and the dose expressed as a Dose Area Product (DAP). 108 radiographs were analyzed for titanium femoral stem with cobalt-chrome head, ceramic cup in a metal bowl and the whole prosthesis – by changing the anode voltage in the range of 70-93 kV and three different variants using the anti-scattered grid (without grid, f (o) = 115, f (o) = 180). EXI value measured​respectively to the entire prosthesis, ceramic cup in a metal bowl and titanium femoral decreases along with the use of grid with a larger angle of lead strips (f (o) = 180). Type of material applied in individual elements of prosthesis affect the value of the DAP. DAP increases when prosthesis is exposed at a distance of 115 cm FFD and anti-scattered gird f (o) = 180 is used, instead of f (o) = 115.
17
Content available remote Ocena stopnia pochłaniania wody przez wybrane rodzaje żywic acetalowych
PL
Materiałom do wykonywania protez ruchomych stawia się coraz wyższe wymagania. Celem pracy było określenie sorpcji wody w wybranych żywicach acetalowych. Wszystkie badane materiały cechowały się sorpcją wody, która największa była w pierwszej dobie, a później ulegała stabilizacji.
EN
Four com. acetal resins were studied for H2O sorption at 37°C for 24 h to 3 months by detn. of mass increase. The sorption intensity was highest during the first 24 h of the contact of the resin with H2O. Some differences in the sorption capacity were observed.
EN
Presented are the results of investigations into the preparation of a peripheral nerve prosthesis. The prosthesis is built up of a multichannel core having a diameter of 2 to 5 mm. The core prepared by freeze drying is housed in a polymeric sleeve. The prosthesis core is made of microcrystalline chitosan (MCCh) while the sleeve is prepared from poly(DL-lactide-coglycolide) copolymer. The usefulness of the prepared biomaterial was assessed by in vivo testing on animals.
PL
W pracy przedstawiono badania prowadzące do opracowania modelu protezy nerwu obwodowego. Proteza zbudowana jest z wielokanałowego rdzenia o średnicy od 2 do 5 mm wytworzonego metodą liofilizacji i osadzonego w tulei polimerowej. Rdzeń protezy wytworzono z mikrokrystalicznego chitozanu (MKCh), natomiast tuleję stanowi błona uzyskana z resorbowalnego kopolimeru poli(DL-laktyd-ko-glikolid). Opracowany biomateriał poddano ocenie przydatności w warunkach in vivo z wykorzystaniem zwierząt.
20
Content available remote Metody pomiarowe do zastosowania w komorze wspomagania sztucznego serca
PL
Protezy służące do wspomagania serca są rozwijane w Fundacji Rozwoju Kardiochirurgii w Zabrzu. Ich głównym zadaniem jest przyspieszenie leczenia mięśnia sercowego pacjentów, u których zdiagnozowano choroby serca i układu krwionośnego. Zastosowanie protezy wspomagającej pracę serca pozwala na znaczne przyspieszenie leczenia chorego serca lub w przypadkach ostatecznych - na oczekiwanie na przeszczep serca. W publikacji zamieszczono analizę metod pomiarowych do zastosowania w protezach serca typu POLVAD (Polish Ventricular Assistant Device). Praca dotyczy zagadnienia bezinwazyjnej metody pomiarowej pozwalające na pomiar ciśnienia krwi w ustalonych miejscach, umieszczonych na protezie oraz wewnątrz protezy sztucznego serca.
EN
In this paper methods analysis for pressure measurement for using in the POLVAD (Polish Ventricular Assistant Device) are introduced. Work is focused on the noninvasive methods for blood pressure measurement in crucial points around heart prosthesis. Mechanical prosthesis used for heart support, are developed by the Foundation of Cardiac Surgery Development in Zabrze. Their main purpose is to aid the heart healing process in patients with cardiac problems. Use of the POLVAD prosthesis helps with speeding up heart recovery process in patients or is being or supports patient waiting for heart transplant.Conducted research is part of “Polish Artificial Heart” program. Main goal of this part of project is introduction of functional noninvasive blood pressure measurement system for POLVAD device and in future for fully artificial heart. Two sensing methods are being introduced: fiber pressure sensor and piezoelectric pressure measurement with. Preliminary results are included, and choice of best method for future development is being pointed out.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.