Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 42

Liczba wyników na stronie
first rewind previous Strona / 3 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  power distribution
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 3 next fast forward last
EN
Complex ramified distribution power networks (DPN) 6-20 kV are characterized by large dimension, development dynamism, insufficient regime information completeness and reliability. Structured hierarchical-multilevel approach to the elementwise calculation of power losses in DPN is proposed. The DPN structural model is described. A substantive description of this approach is given on the example of ramified DPN with n nodes and m sections (transmission line and transformer) with a tree structure.
PL
Złożone rozgałęzione Sieci Elektroenergetyczne (DPN) 6-20 kV charakteryzują się dużym wymiarem, dynamiką rozwoju, niewystarczającą kompletnością informacji o reżimie i niezawodnością. Zaproponowano ustrukturyzowane hierarchiczno-wielopoziomowe podejście do pierwiastkowego obliczania strat mocy w DPN. Opisano model strukturalny DPN. Merytoryczny opis takiego podejścia podano na przykładzie rozgałęzionego DPN z węzłami n i odcinkami m (linia transmisyjna i transformator) o strukturze drzewa.
PL
Fotowoltaika jako proces konwersji promieniowania słonecznego bezpośrednio w energię elektryczną za pomocą ogniw słonecznych jest jednym z najważniejszych odnawialnych źródeł energii. W pracy przeanalizowano wytwarzanie energii elektrycznej z mikroinstalacji fotowoltaicznej, zlokalizowanej w centralnej Polsce, o maksymalnej mocy szczytowej 1,56 kWp, w ciągu dwunastu pełnych miesięcy w latach 2018-2019. Przedstawiona mikroinstalacja fotowoltaiczna to system typu On-Grid, dołączony do sieci elektroenergetycznej niskiego napięcia, a generator fotowoltaiczny zbudowany jest z sześciu najczęściej używanych rodzajów modułów fotowoltaicznych z krzemu polikrystalicznego. Wyniki pomiarów podzielono na procentowe ilości wytworzonej energii w dwóch przedziałach czasowych: miesiącach „letnich” od kwietnia do września oraz pozostałych uznanych za „zimowe”. Przeanalizowano także rozkład mocy wyjściowej falownika dla mikroinstalacji fotowoltaicznej. Celem tej analizy było oszacowanie rzeczywistej dopuszczalnej wielkości współczynnika NPR (Nominal Power Ratio), zdefiniowanego jako stosunek mocy szczytowej generatora PV do mocy nominalnej falownika, z uwzględnieniem jego sprawności. Przeprowadzono również testy symulacyjne, które pozwoliły oszacować optymalną liczbę modułów PV połączonych szeregowo w mikroinstalacji PV.
EN
Photovoltaic as a process of converting solar radiation directly into electricity using solar cells is one of the most important renewable energy sources. The paper analyzes the electricity generation from photovoltaic micro-installation, located in central Poland, with a maximum peak power of 1.56 kWp, within twelve full months in 2018-2019. The PV micro-installation presented is a system On-Grid, connected to a low volt-age power network, and the PV generator is built from the six most commonly used types of PV modules from polycrystalline silicon. The results of the measurements were divided into percentage amounts of generated energy in two time intervals: "summer" months from April to September and others recognized as "winter". They were also analysed output power distribution of the inverter for photovoltaic micro-installation. The purpose of this analysis was to estimate the real acceptable size of the NPR (Nominal Power Ratio) coefficient, defined as the ratio of the peak power of the PV generator to the nominal power of the inverter taking into account its efficiency. Simulation tests were also carried out, which allowed to estimate the optimal number of PV modules connected in series in the PV micro-installation.
EN
The smart grid concept is predicated upon the pervasive use of advanced digital communication, information techniques, and artificial intelligence for the current power system, to be more characteristics of the real-time monitoring and controlling of the supply/demand. Microgrids are modern types of power systems used for distributed energy resource (DER) integration. However, the microgrid energy management, the control, and protection of microgrid components (energy sources, loads, and local storage units) is an important challenge. In this paper, the distributed energy management algorithm and control strategy of a smart microgrid is proposed using an intelligent multi-agent system (MAS) approach to achieve multiple objectives in real-time. The MAS proposed is developed with co-simulation tools, which the microgrid model, simulated using MATLAB/Simulink, and the MAS algorithm implemented in JADE through a middleware MACSimJX. The main study is to develop a new approach, able to communicate a multi-task environment such as MAS inside the S-function block of Simulink, to achieve the optimal energy management objectives.
EN
The article presents the work of the stepless hybrid distribution transformer (HT), as an alternative to the so far applied Automatic Voltage Regulator (AVR) solutions, used to control the voltage in the power system in terms of the fundamental harmonic. The HT is a combination of a conventional distribution transformer and an AC/DC/AC converter connected in series with the transformers secondary winding. In the work the basic control algorithm of the AC/DC/AC converter operated as a series connected additive voltage source in the HT system, has been described. The article contains the preliminary results of computer simulation studies of the model elaborated in PSIM.
PL
W artykule opisano działanie bezstopniowego hybrydowego transformatora dystrybucyjnego (HT), jako alternatywę dla dotychczas stosowanych rozwiązań AVR (Automatic Voltage Regulator), służących do kontroli poziomu napięcia w systemie elektroenergetycznym w zakresie podstawowej harmonicznej. Układ HT to połączenie konwencjonalnego transformatora dystrybucyjnego oraz przekształtnika AC/DC/AC włączonego w szereg z uzwojeniem wtórnym transformatora. W pracy przedstawiono podstawowy algorytm sterowania przekształtnikiem AC/DC/AC jako szeregowe źródło napięcia dodawczego w układzie badanego HT. Artykuł zawiera wstępne wyniki badań symulacyjnych modelu opracowanego w programie PSIM.
PL
Artykuł dotyczy praktycznych aspektów syntezy układu automatycznego sterowania bezzałogowym statkiem głębinowym w zakresie strategii alokacji naporów w układzie napędowym. Rozważanym statek pojazdem jest wyposażony w wielopędnikowy układ napędowy zapewniający ruch o czterech stopniach swobody. W algorytmach rozdziału mocy zastosowano metody optymalizacji z ograniczeniami pozwalające na podstawie sił i momentów uogólnionych wyznaczyć siły naporu jakie winny być wytwarzane przez poszczególne pędniki. Rozpatrując zagadnienie rozdziału mocy jako zadanie programowania kwadratowego oraz programowania liniowego w pracy zaproponowano i porównano dwa algorytmy alokacji naporów. Przeprowadzone badania modelowe pozwoliły na oszacowanie ich jakości oraz efektywności w odniesieniu do szybkości i złożoności obliczeniowej.
EN
This article addresses the practical aspects of the synthesis of an automatic control system for the thrust allocation strategy in the propulsion system of an unmanned underwater vehicle. The vehicle under consideration is a robot submarine equipped with a multi-propulsion system providing four degrees of freedom of movement. The power distribution algorithms are based on limited optimisation methods that allow the determination, on the basis of generalised torques and forces, of how much thrust is required to be produced by individual propulsors. Considering the issue of power distribution as a task of square and linear programming, two algorithms of thrust allocation were proposed and compared. The conducted model tests made it possible to evaluate their quality and efficiency in relation to speed and computational complexity.
PL
W artykule przedstawiono zastosowanie sieci neuronowej do optymalizacji rozpływów mocy w sieciach dystrybucyjnych. Przedstawiono strukturę i parametry zastosowanej sieci neuronowej oraz proces uczenia i testowania sieci neuronowej. Rezultaty uzyskiwane przez sieć neuronową oceniono porównując jej do rezultatów osiąganych przy użyciu metody „Primal dual interior point method” wykorzystywanej przez funkcje optymalizacyjne pakietu „Matpower”. Obliczenia zrealizowano w środowisku obliczeniowym programu Matlab. Analizy obliczeniowe pokazały, iż zaprojektowana sieć neuronowa uzyskuje zbliżone wyniki jak klasyczne algorytmy optymalizacji.
EN
The article presents the use of a neural network to optimize power flows in distribution networks. The structure and parameters of the used neural network as well as the process of learning and testing the neural network are presented. The results of the neural network were compared to the results of the „Primal dual interior point method” method used by the optimization functions of the „Matpower” package. The calculations were made in the Matlab program. Computational analyzes have shown that the designed neural network obtained similar results as classical optimization algorithms.
7
Content available remote Nieobciążone estymatory parametrów rozkładu potęgowego
PL
W pracy sprawdzono właściwości estymatorów parametrów rozkładu potęgowego. Wychodząc z nierówności Rao-Cramera wyznaczono wariancję najefektywniejszego estymatora parametru kształtu. Zaproponowano nową postać nieobciążonego estymatora parametru skali.
EN
The paper examines the qualities of estimators of power distribution parameters. Starting from the Rao-Cramer inequality, the variance of the most efficient estimator of the shape parameter is determined. And a new form of the unbiased estimator of the scale parameter is proposed.
EN
The paper covers the theoretical background and tests of two asynchronous squirrel cage generators connected to voltage source inverters working in parallel. Inverters were connected in parallel by their intermediate direct current circuits by means of auctioneering diodes, and then to a DC power network. The real-time control algorithm of digital signal processor DSP and field-programmable gate array FPGA was used to achieve proper excitation of two different power machines, and to maintain high enough levels of direct current link voltage. Windings of both generators are fed by use of so-called machine side inverters. The asynchronous generator is a voltage source inverter controlled by a field-oriented control algorithm based on the current machine model. To prove robustness of the chosen algorithm, different types of load were applied while generators and inverters worked in parallel.
9
Content available Power distribution in anti-vibration gloves
EN
The article analyses power distribution in an anti-vibration glove. The glove of interest was modelled in a biodynamic model of the Human – Glove – Tool system. The model was a combination of the human model and the glove model specified in the ISO 10068:2012 standard and the model of the vibration tool. To determine the power distribution in the glove, its energy model was developed. The power distribution in the model was determined using numerical simulation in order to show how power was distributed in the dynamic structure of the anti-vibration glove. Three kinds of powers were distinguished, which are related to forces of inertia, dissipation and elasticity. It turned out that out of the three kinds of powers identified in the anti-vibration glove, only one is dominant: namely the power of dissipation.
EN
The article continues the analysis presented in the article „Power distribution in anti-vibration gloves” [6], which described the approach adopted to construct an energy model of the Human – Glove – Tool system (H – G – T). The outcome of the analysis was the power distribution calculated only for the anti-vibration glove. This article continues the energy analysis for another subsystem of the H – G – T system – the human physical model. The energy method was also used to calculate the power distribution in its dynamic structure in order to account for interactions between the elements of the H – G – T system. The results obtained in the study indicate that the power distribution in the human physical model and in the glove model is completely different.
EN
This paper presents a novel method for data analysis and visualization, including real-time visual monitoring and proposal for combined area PQ indices on the example of the developed and operational comprehensive system of registration, archiving and data processing for the wide-area monitoring of power quality in a separated part of real power grid with distributed renewable generation. Real case studies related to power quality disturbances are presented.
13
Content available remote Układ dystrybucji mocy w pojeździe hybrydowym
PL
W artykule przedstawiono problemy związane z poprawnym zaprojektowaniem instalacji elektrycznej pojazdu z napędem hybrydowym (spalinowo- elektrycznym). Pokazana jest topologia układu i uzyskane wyniki - stabelaryzowane parametry wielkoprądowej instalacji elektrycznej pojazdu hybrydowego. W artykule opisano najważniejsze elementy prac projektowych, w tym bilans mocy, dobór zabezpieczeń, dobór przekrojów przewodów, wyznaczenie punktu pracy wentylatora oraz układ soft startu silnika elektrycznego. W podsumowaniu odniesiono się do praktycznego wykorzystania uzyskanych wyników obliczeniowych.
EN
The paper presents problems associated with proper design of an electrical system of a vehicle with a hybrid propulsion system (internal combustion + electric). Topology of the system is shown along with results obtained: tables of parameters of a high current electrical system of a hybrid vehicle. The paper describes major components of the design work, including power balance, safeguards, wire cross sections, determination of the working point of a fan and soft start system for the electric motor. In conclusion, reference is made to the practical application of the calculation results.
Logistyka
|
2015
|
nr 3
2090--2101, CD 1
PL
Wraz z rozwojem motoryzacji pojawił się problem z kurczącymi się zasobami ropy naftowej. Spowodowało to dynamiczny rozwój badań nad paliwami alternatywnymi. W silnikach ZS największą popularność zdobyły estry metylowe kwasów tłuszczowych. Większość obecnie eksploatowanych silników o zapłonie samoczynnym wyposażona jest w generujące wysokie ciśnienia układy wtryskowe typu common rail. W celu zapewnienia odpowiednich parametrów aparatura ta optymalizowana jest do pracy z paliwem o ściśle określonych właściwościach. Stosowanie paliw nawet o lepszej smarności, ale nieznacznie różniącymi się innymi właściwościami wywoływać może niepożądane efekty w postaci wzrostu i zmiany rozkładu sił. W artykule przedstawiono wyniki badań przeprowadzonych na specjalnym mobilnym stanowisku badawczym wyposażonym w pompę wysokiego ciśnienia typu common rail napędzaną silnikiem elektrycznym. Wyniki badań pokazują, że istotny wpływ na zużycie elementów pompy ma wartość i rozkład sił powstających w układzie, a nie jak dotąd sądzono, wartość parametrów fizykochemicznych takich jak smarność.
EN
With the development of the automotive industry the problem with dwindling oil resources become more important. This increases the dynamics of the development of research into alternative fuels . The greatest popularity for supplying CI engines have gained by fatty acid methyl esters. Most of the currently used diesel engines equipped with generating high pressure injection systems common rail. In order to assure performance of this equipment is optimized to work with the fuel with specific properties. The use of fuel even better lubricity, but slightly different other properties may cause adverse effects in the form of growth and changes in the direction of forces. The article presents the results of research carried out on a special mobile bench equipped with a high pressure pump common rail driven by an electric motor. The results show that a significant impact on the amount of wear of the pump is set and the direction of forces arising in the system, and not, as previously thought, the physico-chemical parameters such as lubricity.
EN
The main aim of this study is to present an energy comparison of two human physical models taking into account hand-arm vibrations, which are based on the power distribution in their dynamic structure. The method used in the study takes advantage of a close relationship between the dynamics of the systems and energy-related phenomena that occur within them. The energy comparison of the two human physical models required construction of energy models of a Human-Tool system and finding their solutions. For this purpose, programs have been developed using the MATLAB/simulink software to simulate power distribution in the systems. The simulation revealed a discrepancy between the two models in terms of three types of powers and globally in the system as a whole.
EN
Pulsed power network is proposed for reliable and low loss electrical power distribution among various type of power sources and consumers. The proposed scheme is a derivative of power packet network so far investigated that has affinity with dispersion type power sources and has manageability of energy coloring in the process of power distribution. In addition to these advantages, the proposed scheme has system reliability and low loss property because of its intelligent operation performed by individual nodes and direct relaying by power routers. In the proposed scheme, power transmission is decomposed into a series of electrical pulses placed at specified power slots in continuous time frames that are synchronized over the network. The power slots are pre-reserved based on information exchanges among neighboring nodes following inherent algorithm of the proposed scheme. Because of this power slots reservation based on decentralized intelligence, power pulses are directly transmitted from various power sources to consumers with the least power dissipation even though a partial failure occurs in the network. The network operations with the proposed scheme is simulated to confirm the algorithms for the power slots reservation and to evaluate the power network capacity.
PL
Na etapie doboru przewodów szynowych należy uwzględnić przede wszystkim obciążalność prądową poszczególnych elementów oraz przebieg trasy. Nie mniej ważny jest również wybór odpowiednich akcesoriów.
18
Content available remote On a characterization of a power distribution
EN
A measure of dependence called pseudo-covariance and related to covariance was proposed by Pawlas and Szynal [4]. It was used, among other things, in a characterization of a power distribution. Here we generalized that result.
EN
The study analyses differences in the flow of energy for two human physical models specified in the ISO 10068:2012 standard. For this purpose, two mathematical models of the Human–Tool system in question were developed using the Lagrange equation of the second kind. Corresponding energy models were then created for each mathematical model and tested by means of digital simulation in the MATLAB/Simulink environment. The study revealed a discrepancy between the models in terms of different types of power and in the total power.
PL
Praca dotyczy syntezy systemu automatycznego sterowania robotem podwodnym w zakresie problemu rozdziału mocy w wielopędnikowym układzie napędowym. Do alokacji naporów zastosowano metody optymalizacji z ograniczeniami, pozwalające na wyznaczanie wektora naporów na podstawie wektora sił uogólnionych. Rozważono i porównano dwie metody rozdziału mocy dla robota realizującego ruch poziomy płaski o trzech stopniach swobody, rozpatrując zagadnienie alokacji naporów jako zadania programowania kwadratowego oraz programowania liniowego.
EN
The paper focuses on a problem of power distribution in a multi-thrusters propulsion system of an underwater robot. To finding an optimal thrust allocation for demanded propulsive forces and moments both the linear programming and quadrating programming techniques are applied. Regarded thrust allocation methods are directed towards minimization of energy expenditures necessary to obtain required control and from this point of view the presented algorithms are compared.
first rewind previous Strona / 3 next fast forward last