EN
Using the waste energy generated in any production process is the one of possible ways of increasing energy efficiency. In the industrial cultivation of vegetable sprouts for food purposes, significant amounts of low-temperature waste heat are released, the source of which is the metabolic processes taking place inside the seeds. In typical installations, this energy is lost to the environment, while it could be utilised, for example, to heating the water used to irrigate the plants. This paper presents a concept of utilizing waste heat generated during the germination process of seeds using plate heat exchangers and the analysis of the potential for reducing the energy consumption of installations for vegetable sprout production. For this purpose, transient simulations were conducted using a developed simulation model of the technological line in Flownex Simulation Environment. In order to formulate a reliable simulation model, relevant device parameters and process data were collected. After building the model and calibrating it appropriately, an analysis of the variability of the values of all process parameters was performed, and the potential for recovering waste heat was determined. The results obtained from numerical modelling were verified against the results obtained from the production line and shows, that the amount of recoverable waste heat in the entire production cycle was about 5 GJ.
PL
Praca podejmuje tematykę związaną z układami ORC. Analizuje wpływ właściwości czynnika organicznego na pracę instalacji doświadczalnej o mocy elektrycznej równej 1 kW, zasilanej ciepłem niskotemperaturowym, działającej w oparciu o organiczny obieg Rankine'a (ORC), która w porównaniu do powszechnie znanych instalacji, odznacza się jedną, zasadniczą różnicą: procesem rozprężania. Urządzenie rozprężające, stosowane w tradycyjnych systemach ORC, zastąpione jest przez dwa, połączone ze sobą zbiorniki, pomiędzy którymi umieszczona jest pompa. Podstawowe parametry pracy instalacji w warunkach znamionowych określono dla dziesięciu wybranych czynników chłodniczych: R134a, R152a, R227ea, R236fa, R245fa, R290, R600a, R717, R1234yf, R1234ze(E). Analogiczne obliczenia przeprowadzono również dla układu ORC pracującego w takich samych warunkach i zapewniającego taką samą moc.
EN
The thesis analyze the influence of the organic fluids properties on the performance of the experimental installation with electric power 1kW driven by the waste heat and working based on the organic Rankine cycle. Compared to commonly used ORC system the examined installation is characterized by one essential difference: expansion process. The expansion machine, used in typical ORC structure, is replaced by two connected tanks, between which the turbine is installed. The basic operation parameters in nominal conditions were determined for ten selected working fluids: R134a, R152a, R227ea, R236fa, R245fa, R290, R600a, R717, R1234yf, R1234ze(E). Analogical calculations were also done for conventional ORC system working with the same parameters and providing the same electric power.
PL
Organiczny obieg Rankine’a to obiecująca technologia pozwalająca na wykorzystanie ciepła nisko- i średniotemperaturowego, którego źródłem mogą być procesy przemysłowe i odnawialne źródła energii, do produkcji energii elektrycznej. Istota jego pracy sprowadza się do pracy parowego obiegu Rankine’a z tą różnicą, że czynnikiem roboczym nie jest woda, a związek organiczny lub nieorganiczny, charakteryzujący się niską temperaturą przemiany fazowej. Artykuł przybliża podstawowe zagadnienia związane z instalacjami ORC: prezentuje ich zasadę działania, wskazuje różnice w stosunku do układów parowych, przybliża podstawowe właściwości czynników roboczych, charakteryzuje źródła ciepła i opisuje możliwości ich wykorzystania oraz analizuje rynek instalacji ORC.
EN
Organic Rankine Cycle (ORC) is a promising technology which allows utilizing low and middle temperature heat from industrial processes or renewable energy sources, to production electrical energy. The organic Rankine cycle works like a Clausius–Rankine cycle but uses organic working fluid with low boiling point instead of water. The article presents basics issues concerning ORC installations. It describes the principle of operation, presents the comparison with steam cycle, discusses the properties of working fluids, characterizes the heat sources giving examples of their usage, and analyzes current market of ORC installations.
EN
Determined are factors of a 900 MW supercritical coal-fired power unit working with the use of a flue gas heat recovery system. Analysis is made of various options of flue gas heat recovery for heating the condensate flowing through the low-pressure regeneration system as well as the feed water in the high-pressure regeneration exchangers. Examined was the influence of a localization of a place where the heated condensate is injected into the circuit on the power unit efficiency and capacity. The analysis was carried out for two different ways of waste heat use - in one of them it is only the heat recovered from flue gases at the boiler outlet (after the air heater) that is used to heat water in the regeneration system while in the other utilized is also the additional heat recovered from flue gases before the air heater. Investigations were made for flue gases produced in the process of hard and brown coal combustion separately.
PL
Wyznaczono wskaźniki pracy nadkrytycznego bloku węglowego o mocy 900 MW pracującego z systemem odzysku ciepła ze spalin. Przeprowadzono analizę różnych wariantów odzysku ciepła ze spalin wylotowych z kotła do podgrzania kondensatu płynącego w regeneracji niskoprężnej oraz wody zasilającej przepływającej przez wymienniki regeneracji wysokoprężnej. Badano wpływ miejsca wprowadzania podgrzanego kondensatu do obiegu na sprawność i moc bloku. Analizę prowadzono dla dwóch sposobów wykorzystania ciepła ze spalin. W pierwszym wykorzystuje się wyłącznie ciepło ze spalin wylotowych z kotła (za podgrzewaczem powietrza), natomiast w drugim do podgrzania wody w układzie regeneracji wykorzystuje się również spaliny pobierane przed podgrzewaczem powietrza. Rozważania prowadzono dla spalin powstałych w wyniku spalania węgla kamiennego oraz brunatnego.
PL
Przedstawiono analizę wykorzystania niskotemperaturowego ciepła odpadowego będącego wynikiem dodatkowego schłodzenia spalin zza kotła energetycznego. Analiza dotyczy bloku ciepłowniczego klasy 100 MW. Przedstawiono przegląd możliwych sposobów zagospodarowania tego ciepła oraz fizyczno-techniczne uwarunkowania jego wykorzystania. Zaprezentowano model ciepłowniczego bloku parowego zbudowanego w komercyjnie dostępnym oprogramowaniu. Wyniki otrzymane za pomocą modelu porównano z rzeczywistymi danymi doświadczalnymi. Przedstawiono możliwości wykorzystania ciepła niskotemperaturowego oraz charakterystyki bloku w zmienionych warunkach pracy po ich zastosowaniu.
EN
The analysis of the use of low temperature waste heat from the power plant unit of 100 MW power is presented. An overview of possible heat management ways and physical-technical conditions of its use is presented. The calculations were performed using commercially available software. The obtained results were compared with experimental data. The possibility of using low temperature heat and the characteristics of the power plant in the off-design operation are presented.
6
PL
W artykule opisano źródła ciepła niskotemperaturowego oraz sposoby pozyskiwania energii zawartej w górotworze za pośrednictwem pali nośnych stosowanych w budownictwie. W pracy podano zasadność wykorzystywania tzw. "filarów energii". Zaprezentowano geotechniczne metody wykonania pali nośnych, a także sposoby ich działania w układzie eksploatacji i magazynowania ciepła w ośrodku gruntowym. Kolejnymi poruszanymi zagadnieniami są wymagania stawiane właściwościom termicznym kamienia cementowego stosowanego do wykonywania pali, służących jako czynnik pośredniczący w wymianie ciepła pomiędzy górotworem a obiektem budowlanym.
EN
There is described in the paper low-temperature heat sources and ways of energy receive from ground through the agency of piles applied in construction industry. In the paper is described legitimacy of made use so-called "energy piles" in buildings. There are also presented geotechnical methods of piles execution and manners of their operation as heat exploitation and storage in ground. Next discussed problems are requirements of concrete thermal parameters used for making piles worked as heat transfer element between ground and structure.