Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 22

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  heterotrophic bacteria
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
This research aimed to discover the macroscopic, microscopic, and physiological characteristics and the genus of heterotrophic bacteria found in the schmutzdecke or biofilm layer in slow sand filters. The isolation of heterotrophic bacteria in the schmutzdecke applied the pour plate and quadrant streak method, while the characterization used macroscopic, microscopic, and physiological tests. Samples were taken from the schmutzdecke on top of the filter layer, and they were diluted 3, 4, and 5 times, then grown in Nutrient Agar media in order to isolate heterotrophic bacteria. The results of the research were analyzed using the identification manual books titled Bergey’s Manual of Determinative Bacteriology, 9th edition and Manual for The Identification of Medical Bacteria, 3rd edition. These manuals show the names of the genus of bacteria in the schmutzdecke layer. On the basis of the identification results from macroscopic, microscopic, and physiological tests, there were 4 dominant genera out of 18 living isolates obtained from the schmutzdecke layer, namely Kurthia gibsonii, Bacillus badius, Bacillus firmus, and Bacillus lentus. The similarity percentage of these 4 isolates was 83%, 81%, 85%, and 77% respectively.
PL
W przemyśle spożywczym jakość wody jest istotnym czynnikiem wpływającym na bezpieczeństwo zdrowotne produktu finalnego. Aby przeciwdziałać zanieczyszczeniu żywności, został nałożony obowiązek wprowadzania systemu HACCP, którego zasadniczym elementem jest m.in. monitoring wody technologicznej. Obejmuje on procedury identyfikacji i eliminowania zagrożeń fizykochemicznych i mikrobiologicznych. Ocena ryzyka mikrobiologicznego wody, oparta na nowych aktach prawnych i informacjach epidemiologicznych, potwierdza konieczność rozszerzania parametrów dla wody pitnej podlegających monitorowaniu, które mogą stanowić potencjalne zagrożenie dla zdrowia ludzkiego. W artykule omówiono przyczyny i skutki mikrobiologicznego zanieczyszczenia wody technologicznej w aspekcie systemu HACCP, ze szczególnym uwzględnieniem mikroflory heterotroficznej.
EN
In the food industry, water quality is an important factor affecting the health safety of the final products. To counteract food contamination, the HACCP system has been introduced, with the monitoring of technological water as an important element. It includes procedures for identifying and eliminating physico-chemical and microbiological hazards. The assessment of microbiological risk of drinking water, based on new legal acts and epidemiological information, confirms the need to extend of the monitored parameters which may be a potential hazard to human health. The article discusses the causes and effects of microbiological contamination of process water in the aspect of HACCP system, with particular emphasis on heterotrophic microflora.
PL
Celem badań było zweryfikowanie możliwości modelowania (z zastosowaniem modelu ASM-1) usuwania związków organicznych, wyrażonych jako chemiczne zapotrzebowanie na tlen (ChZTCr), przez filtry włókninowe, ze szczególnym uwzględnieniem ich grubości. Przyjęto założenie, że procesy biochemiczne zachodzące na filtrach podczas przepływu ścieków podczyszczonych wcześniej w osadniku gnilnym, można modelować jako szereg reaktorów przepływowych z idealnym wymieszaniem. Modelowano skuteczność usuwania ChZTCr dla trzech grubości włókniny filtracyjnej: 1,8; 3,6 i 7,2 mm. Założono, że za pomocą powyższego modelu, będzie można zidentyfikować czynniki warunkujące obserwowaną wcześniej w ramach badań empirycznych [SPYCHAŁA, ŁUCYK 2015] zależność wpływu grubości warstwy filtracyjnej na efektywność usuwania substratu organicznego. Obliczenia modelowe wykazały, że potraktowanie warstwy filtracyjnej jako szeregu reaktorów z idealnym wymieszaniem zadowalająco odzwierciedla skuteczność usuwania zanieczyszczeń organicznych przez filtry o grubości warstwy filtracyjnej 7,2 mm dzięki stosunkowo długiemu czasowi retencji. Modelowanie nie dało zadowalających wyników w przypadku filtrów o mniejszej grubości warstwy filtracyjnej, czego główną przyczyną były krótkie średnie czasy przetrzymania ścieków.
EN
The aim of the study was to verify the possibility of modelling (using the ASM1 model) the removal efficiency of nonwoven filters, with special emphasis on their thickness. It was assumed that the biochemical processes taking place on the filters during the flow of wastewater pre-treated earlier in a septic tank, can be modeled as a series of flow reactors with ideal mixing. Three kinds of nonwoven filters of thickness: 1.8 mm, 3.6 mm and 7.2 mm were examined. On the basis of observations made in the course of empirical studies it was assumed that a major impact on the efficiency of removal of the substrate has a thickness of the filter layer (average retention time). Modelling calculations have shown that the treatment of the filter as a series of reactors with ideal mixing and using ASM1 model satisfactorily simulates the efficiency of organic contaminants removal by the filter having a thickness of 7.2 mm thanks to the relatively high retention time. Modelling does not give satisfactory results for filters of smaller thickness of the filter layer. The main reason was the short average retention time.
EN
The range of solar radiation reaching the air-water inter-phase, medium wave UV radiation, i.e. UVB 290-320 nm and UVA 320-400 nm, is of the highest biological importance due to its harmful effects. Radiation within this range causes DNA damage (lethal effect) or limits the growth of organisms by inhibiting enzyme synthesis, reducing active transport, or by inducing mutations. The studies were carried out in 2007 based on samples water collected from surface microlayer (SM) (up to 150 [mu]m) and subsurface water (SSW) (25 cm) of pelagic zone of eutrophic lake. The representative collection of bacterial strains was isolated from collected samples. The following are measured: the DNA and cellular protein synthesis activity, respiration activity of the bacteria and activity of hydrolytic enzymes in control cultures, subjected to UVB radiation (applied dose 100 mW cm[^-2]) and with and without humic substances (HS) (final concentration 100 mg L[^-1]) playing role of compounds potentially protective from UV radiation. UVB irradiation had the strongest inhibiting impact on production of DNA in bacterial cells (12-23% of that in non-irradiated samples). UVB radiation also inhibits the synthesis of cellular protein (27-43% of that in non-irradiated samples) and bacterial respiration activity (44-48%). UVB radiation had by far the lowest impact on the activity of hydrolytic enzymes. HS may function as a protective agent against UV radiation only in DNA synthesis. No significant differences in response to UVB were found between planktonic and neustonic bacteria.
EN
The phytoseston flora and heterotrophic bacteria from the two intersecting rivers were studied during the intensive water flow (from October 2006 to May 2007). The physical and chemical measurements indicated that the water quality in the rivers regarding their purity, had slightly improved in the Nielba River and deteriorated in the Wełna River, at the sites behind the intersection zone. It was in the agreement with the studied phytoseston diatom communities (dominated by eutraphentic taxa). Phytoplankton during the winter months was dominated by Aulacoseira granulata. The importance of species from the genera Oscillatoria, Planktolyngbya, Tychonema, Planktothrix, Scenedesmus/Desmodesmus, Nitzschia and Fragilaria increased in spring and autumn. Heterotrophic bacteria occurred in considerably higher numbers in the Wełna River than in the Nielba River, with a significant decrease in the waters of the Wełna River behind the river-intersection. All analyses revealed that the waters in the Wełna River were more polluted with organic compounds than in the Nielba River locations.
PL
Badaniom mikrobiologicznym i chemicznym poddano wodę wodociągową dostarczaną do mieszkańców aglomeracji trójmiejskiej z dwóch systemów - ujmującego wodę powierzchniową (oczyszczaną w procesach koagulacji, ozonowania i sorpcji na węglu aktywnym) oraz ujmującego wody podziemne (oczyszczane w procesach napowietrzania i filtracji przez złoża katalityczne). Stwierdzono, że w badanych systemach wodociągowych zachodził wtórny wzrost bakterii heterotroficznych, przy czym był on większy w wodzie pochodzącej z ujęcia powierzchniowego dezynfekowanej chlorem lub mieszaniną chloru i dwutlenku chloru, niż w niedezynfekowanej wodzie z ujęć podziemnych. W początkowym odcinku sieci rozprowadzającej oczyszczoną wodę powierzchniową średnia liczba bakterii (niezależnie od środka dezynfekcyjnego) wzrosła o 1log, a na w sieci rozprowadzającej niedezynfekowaną wodę podziemną tylko o 0,5log. Do zasadniczych przyczyn wtórnego wzrostu bakterii w wodzie wodociągowej pochodzącej z ujęcia powierzchniowego należy zaliczyć szybki spadek stężenia chloru pozostałego i duże stężenie tlenu rozpuszczonego, a także prawdopodobnie większą zawartość przyswajalnego węgla organicznego niż wodzie podziemnej. Największy wzrost liczby bakterii, dochodzący do 2log, zanotowano w końcówce sieci rozprowadzającej oczyszczoną wodę powierzchniową w odległości 15,6 km podczas zmiany środka dezynfekcyjnego z chloru gazowego na dwutlenek chloru. W tym czasie stwierdzono znaczący (śr. ponad 3-krotny) wzrost zawartości OWO, prawdopodobnie uwalnianego z osadów na ściankach przewodów wodociągowych oraz spadek stężeń pozostałego chloru i dwutlenku chloru, odpowiednio do średnich wartości 0,03 gCl2/m3 i 0,027 gClO2/m3. Prowadzone obecnie prace badawcze przy użyciu metod bezpośredniego liczenia komórek bakterii z zastosowaniem mikroskopu epifluorescencyjnego, umożliwią określenie całkowitej liczby bakterii, w tym żywych, w wodzie wodociągowej, a także ocenę ich struktury morfologicznej.
EN
The tap water supplied to the inhabitants of Gdansk, Gdynia and Sopot via two distribution systems was analyzed for microbiological and chemical composition. One of the distribution systems involves an intake of surface water treated by coagulation, ozonation and adsorption onto active carbon; the other one uses two intakes of groundwater treated by aeration and filtration through a catalytic bed. In both the distribution systems the regrowth of heterotrophic bacteria was found to occur, which was stronger in the surface water being treated and disinfected (with chlorine, or a mixture of chlorine and chlorine dioxide) than in the groundwater being treated without disinfection. In the initial section of the surface water distribution system the average number of bacteria (regardless of the disinfectant used) increased by 1log, while in the system distributing non-disinfected groundwater an increase of only 0.5log was observed. The underlying causes of bacterial regrowth in the tap water drawn from the surface water intake can be itemized as follows: a rapid decrease in residual chlorine concentration, a high dissolved oxygen concentration and, seemingly, a higher content of assimilable organic carbon as compared to that in the tap water drawn from the groundwater intake. The largest increase in the number of bacteria, up to 2log, was observed in the end section of the system distributing treated surface water, at the distance of 15.6 km, during replacement of gaseous chlorine by chlorine dioxide. This increase was paralleled by a significant (on average more than threefold) rise in the content of TOC (probably released from the deposits on the pipe walls) and by a decrease in the concentrations of residual chlorine and chlorine dioxide to values averaging 0.03 gCl2/m3 and 0.027 gClO2/m3, respectively. Researches are underway, where use is made of direct methods to count bacterial cells (epifluorescence microscope). It is expected that such examinations will make it possible to determine the total number of bacteria (including those survived) in the tap water, as well as to assess their morphological structure.
EN
This study determined the numbers and distribution of heterotophic and lipolytic bacteria and the activity of lipases in the water of the Słupia River, in the section of the river that flows through the city of Słupsk. From spring to fall the mean number of heterotrophic bacteria remained at a relatively constant level (158.3 × 103 cells cm^-3 – 169.4 × 103 cells cm^-3), whereas in winter a sudden drop to only 18.3 × 103 cells cm^-3 was found. The numbers of heterotrophic bacteria in the whole studied section of the river were similar. The mean number of lipolytic bacteria reached a maximum in spring (12.9 × 103 cells cm^-3), was high in summer (10.5 × 103 cells cm^-3), and reached a minimum (1.3 × 103 cells cm^-3) in winter. Lipolytic bacteria accounted for only 5 to 8% of the total number of heterotrophic bacteria. No marked differences in the numbers of lipolytic bacteria were determined within the section of the river studied. The highest levels of lipase activity were determined in spring (18.9 nM MUF dm^-3 h^-1) and fall (19.9 nM MUF dm-3 h-1), while the lowest (11.0 nM MUF dm^-3 h^-1) were noted in winter. There were no differences in the level of activity of lipolytic enzymes among the sites studied.
EN
This survey has been aimed at estimation of the Vistula water number of heterotrophic bacteria, capable of decomposition of various phosphorus compounds, both organie and inorganic ones, as well as determination of bacteria participation in biogeochemical phosphorus cycle. The studies were conducted from spring 2000 to spring 2001. The water for analyses was sampled from three current sites of the Włocławek Reservoir along former bed of the Vistula River. In this studies has been estimated number of heterotrophic bacteria, capable to release mineral phosphorus from organie and inorganic matter. The result of the conducted study demonstrated that the key role in recovery of biologically available phosphorus amounts is the one of bacteriological phosphatases.
PL
Celem pracy było oznaczenie liczebności bakterii heterotroficznych w wodzie Wisły, zdolnych do rozkładu różnych związków fosforu zarówno organicznych, jak i nieorganicznych oraz określenie udziału bakterii w cyklu biogeochemicznym fosforu. Badania prowadzono od wiosny 2000 r. do wiosny 2001 r. Próbki wody do badań pobierano z trzech stanowisk nurtowych Zbiornika Włocławskiego wzdłuż dawnego koryta rzeki Wisły. W badaniach oznaczano liczebność bakterii heterotroficznych zdolnych do uwalniania mineralnego fosforu z materii organicznej i nieorganicznej. Wyniki przeprowadzonych badań wskazują, że najważniejszą rolę w odbudowie dostępnej biologicznie puli mineralnego fosforu odgrywają bakteryjne fosfatazy.
EN
The results of two step bioleaching (autotrophic after heterotrophic) of mine wastes from heap "Jan" in Zloty Stok were presented. The results of the performed processes are very promising. 67 % of arsenic was extracted and exceedance of its permitted quantities in soil was reduced 3 times.
PL
Przedstawiono wyniki badań dwuetapowego bioługowania (neutralnego i kwaśnego) odpadów pogórniczych zdeponowanych na hałdzie "Jan" w Złotym Stoku. Uzyskane wyniki dowiodły słuszności podjętych badań. Wyługowaniu uległo na przykład 67 % arsenu zawartego w materiale. Taki wynik spowodował, że przekroczenie dopuszczalnego poziomu zawartości arsenu w glebie zmalało trzykrotnie.
10
Content available remote Day-to-night activity of bacteria in the surface microlayer of eutrophic lake
EN
This study examined changes of bacteria numbers in the surface microlayer (SM) and subsurface water (SW) of a lake during a day- and night-time. The research also addresses the synthesis of DNA and cell protein as well as the activity of cellular dehydrogenases depending on time of the day. Results demonstrated that in spring and summer the numbers of bacteria (per cm[^3]) in the SM was significantly greater during night-time than day-time (average: May, daytime - 30.058 x 10[^6], night-time - 71.343 x 10[^6]; July, day-time - 10.801 x 10[^6], night-time - 40.353 x 10[^6]). In October, numbers of bacteria in day-and night-time were not statistically different (respectively: 5.841 x 10[^6] and 3.664 x 10[^6]). Results indicated also that the rate of DNA synthesis by SM bacteria was much higher in the night-time (average: May - 2.049 x 10[^-6] pg h[^-1] cell[^-1]; July - 1.363 x 10[^-6] pg h[^-1] cell[^-1]), than in the day-time (average: May . 0.7263 x 10[^-6] pg h[^-1] cell[^-1]; July - 0.3404 x 10[^-6] pg h[^-1] cell[^-1]). In contrast, in October the values of DNA synthesis by SM bacteria were higher in night-time. These changes are significantly smaller in SW at a depth of several dozen centimetres. However, no significant impact was observed of a time of the day on the activity of protein synthesis and activity of cellular dehydrogenases by bacteria inhabiting SM and SW.
11
Content available remote Impact of humic substances on bacterioplankton in eutrophic lake
EN
This paper presents the results of resarch on impact of humic substances (HS) on bacterioplancton in eutrophic Lake Jeziorak (north-eastern Poland). In cultures of natural bacteria from the lake water, enriched with 0, 5, 10, 25 and 50 mg dm[^-3] of HS (natural HS - isolated from lake water or commercial HS - sodium salt of humic substance; Sigma-Aldrich), were determined the following parameters: total number of bacteria (TNB), number of heterotrophic bacteria (CFU), bacterial production (BP) (measured with [[3]H]methyl thymidine method) and general activity of esterases. Natural HS had a more positive impact on bacterial growth, bacterial production and activity of esterases than the commercial preparation HS. The highest TNB and CFU was observed when the water was enriched with 25 mg dm[^-3] of natural HS. Ali concentrations of the natural HS stimulated bacterial production. The activity of hydrolytic enzymes increased with rising concentrations of natural HS.
EN
The response of soil microflora to increasing concentration of three pesticide preparations containing diazinon (insecticide), linuron (herbicide) and mancozeb + dimethomorph (fungicide) as an active substances, was determined under laboratory conditions. All pes.ticides were applied at three different dosages, i.e. 7, 35 and 700 mg kg[^-1] soil for the insecticide, 4, 20 i 400 mg kg[^-1] soil for the herbicide and 15, 75 and 1500 mg kg[^-1] soil for the fungicide mixture. The lowest dosages corresponded to the maximum predicted environmental concentration (PEC) of pesticides applied in field conditions, while the other dosages were the multiplicities of PEC. After 1, 14 and 28 days of experiment the numbers of heterotrophic bacteria, fungi and bacteria in.volved in nitrogen transformation (nitrifying, denitrifying and N[2]-fixing bacteria) was estimated. The numbers of colony forming units (CPU) of respective groups of microorganisms were deter.mined on selective media by means of the serial dilution technique and the spread plate method. The plate-count data indicated that pesticide used affected the numbers of tested microbial groups. All chemicals stimulated the numbers of hetero.trophic bacteria and fungi at the higher dosages. However, the reverse effect was detected at the beginning of the experiment. In turn, bacteria involved in nitrogen turnover, particularly N[2]-fixing and nitrifying bacteria, were the most sen.sitive to the tested pesticides and their numbers were significantly reduced on each time-point. This great susceptibility of these physiological groups of microorganisms predispose them to be warning biomarkers for the side-effects of envi.ronmental pollution caused by chemicals.
13
Content available remote Bioleaching of polish black shale
EN
Heterotrophic pretreatment combined with autotrophic bioleaching of Polkowice black shale were studied. Combination of these two processes was introduced as two-stage process which turned out to be more efficient in the terms of metals extraction. The sequence of preliminary heterotrophic and further autotrophic bioleaching was found as most reliable processing manner, since heterotrophic process provides the material’s surface area expansion, and therefore strong influences rate and efficiency of autotrophic leaching. Besides, it was found that tube bioreactors designed specially for hereby research ensure better processing condition than Erlenmeyer flasks in the terms of extraction speed and efficiency.
PL
Zostały przeprowadzone badania nad wykorzystaniem kombinacji procesów bioprzygotowania z użyciem bakterii heterotroficznych i bioługowania za pomocą bakterii autotroficznych próbek rudy łupkowej otrzymanej z kopalni Polkowice. Kombinacja tych dwóch procesów została przedstawiona jako proces dwu-stadialny, który zapewnia bardziej efektywniejszą ekstrakcje metali z surowca mineralnego. Kolejność realizacji procesu dwu-stadialnego okazała się być bardziej skuteczna, gdyż proces z użyciem heterotroficznych mikroorganizmów powoduje, że powierzchnia surowca staje się bardziej podatna na bioługowanie z użyciem autotroficznych mikroorganizmów. Dodatkowo zostało wykazane, że reaktory rurowe, specjalnie zaprojektowane do tych badań, były lepsze w porównaniu do procesu realizowanego w kolbach stożkowych.
PL
Badania przeprowadzono na modelu fizycznym filtru pospiesznego ze złożem formowanego węgla aktywnego WG-12 firmy GRYFSKAND. Złoże filtracyjne zostało uaktywnione biologicznie. Badania obejmowały pracę filtru przed wyłączeniem go z eksploatacji, postój filtru oraz pracę filtru po jego ponownym włączeniu do eksploatacji. Wyodrębnione serie dotyczyły postoju filtru trwającego odpowiednio 1 dobę, 2 doby i 6 dób. Filtr pracował przed wyłączeniem i po ponownym włączeniem do eksploatacji ze stałą prędkością 5 m/h. Filtrowano pozbawioną chloru poznańską wodę wodociągową z dodatkiem chlorku amonu, którą napowietrzono i doprowadzono do temperatury 18 stopni C. Oznaczenie aktywności mikrobiologicznej biomasy wskazywało na obecność bakterii heterotroficznych w złożu filtracyjnym. Bakterie te uczestniczyły w procesie asymilacji azotu amonowego z wody oraz rozkładały biodegradowalne związki organiczne obecne w filtrowanej wodzie. Wykazano, że wyłączenie filtru z eksploatacji stworzyło dogodne warunki do rozwoju bakterii heterotroficznych w złożu i przebiegu procesu amonifikacji. Po ponownym załączeniu filtru do eksploatacji, niezależnie od czasu jego postoju, zaobserwowano wysoką zawartość azotu organicznego w filtracie, jako skutek wymywania obumarłych komórek bakteryjnych.
EN
The study was performed with a physical model of a rapid filter involving an activated WG-12 (GRYFSKAND) carbon bed. The filter bed was activated biologically. Experiments (three series) were carried out to investigate filter performance prior to shut-down, filter behavior during shut-down, and filter performance after shut-down. The shut-down period had a duration of 1 day, 2 days and 6 days, respectively. Before and after shut-down, filtration velocity was constant (5 m/h). The samples subjected to filtration contained chlorine-free tap water (from the waterworks of Poznan) treated with appropriate doses of ammonium chloride and aerated, water temperature being adjusted to 18 C. The determined microbiological activity of the biomass suggested that heterotrophic bacteria were present in the filter bed. The bacteria participated in the process of ammonia nitrogen assimilation from the water and degraded the biodegradable organic compounds that were present there. It was demonstrated that the shut-down period provided favorable conditions for the growth of heterotrophic bacteria in the filter bed and for the ammonification process. After the filter had been restarted upon shut-down, a very high organic nitrogen content was observed in the filtrate due to the elution of dead bacterial cells.
PL
W pracy omówiono doświadczenia wynikające z wprowadzania dwutlenku chloru do dezynfekcji wody oczyszczonej na stacji "Mosina", zaopatrującej aglomerację poznańską w wodę wodociągową. Stwierdzono, że w chwili osiągnięcia jednakowego udziału dotychczas stosowanego chloru i nowo wprowadzonego dwutlenku chloru (50%/50%)) nastąpił niekontrolowany rozwój bakterii w wodzie, który został zahamowany dopiero w miarę wzrostu udziału chloru w mieszaninie dezynfektantów. Ponadto ustalono, że stosując oba środki dezynfekcyjne, zmienna powinna być dawka chloru, a dwutlenek chloru powinien być dawkowany w stałej ilości. Wykazano, że wprowadzenie nowego reagenta do wody zmieniło jej skład chemiczny, na skutek czego nastąpiły zaburzenia utrwalonej przez wiele lat równowagi w sieci wodociągowej. Ponowne doprowadzenie do stabilizacji wody w sieci było procesem długotrwałym. Rozległy system wodociągowy aglomeracji poznańskiej wymaga dobrego zabezpieczenia wody przed wtórnym zanieczyszczeniem oraz ciągłej kontroli jej jakości, przede wszystkim w zakresie analizy bakteriologicznej. Zastosowanie samego dwutlenku chloru do dezynfekcji wody w stacji wodociągowej "Mosina", bez zwiększenia skuteczności usuwania substancji organicznych, nie było możliwe.
EN
The paper gives an account of the experience gained while implementing chlorine dioxide for water disinfection at the Mosina Water Treatment Plant, which supplies tap water to the city of Poznan. It was found that when the proportion of the chlorine used so far to the chlorine dioxide being implemented was 50%/50%, this was paralleled by an uncontrolled bacterial growth in the water, which was inhibited by increasing the proportion of chlorine in the mixture of the two disinfectants. Another finding produced by the study was that when both the disinfectants were applied, it was possible to vary the chlorine dose while chlorine dioxide had to be dosed in the same amount. The addition of a new reagent brought about changes in the chemical composition of the water, thus disturbing the balance that had stabilized in the water-pipe network for many years. The process of restoring water stabilization in the pipeline was a long-term one. The large water supply system for the city of Poznan requires efficient actions to prevent water recontamination, as well as a reliable, continuous control of water quality primarily to ensure bacteriological safety. The application of chlorine dioxide alone to water disinfection at the Mosina Water Treatment Plant without increasing the efficiency of organic matter removal was found to be a failed attempt.
PL
Omówiono wyniki badań przeprowadzonych na modelu fizycznym filtru pospiesznego z biologicznie aktywnym piaskowym złożem filtracyjnym. Przeanalizowano cykle filtracyjne przy prędkości filtracji 5 m/h i 10 m/h i temperaturze wody 15 stopni Celsjusza. Stwierdzono, że w miarę przedłużania czasu filtracji azot amonowy był okresowo usuwany przy zużyciu tlenu mniejszym od wynikającego ze stechiometrii reakcji nitryfikacji. Wynikało z tego, że w złożu filtracyjnym, oprócz nitryfikacji, zachodził także proces asymilacji azotu amonowego przez bakterie nitryfikacyjne i heterotroficzne. Wykazano, że przyrost błony biologicznej przy wyższej prędkości filtracji był wolniejszy w wyniku stałego odrywania się części organizmów heterotroficznych i powolnego przyrastania struktur bakterii nitryfikacyjnych odporniejszych na działanie strumienia przepływającej wody. W efekcie, przy większych prędkościach filtracji, niższym zużyciu tlenu od wynikającego ze stechiometrii reakcji nitryfikacji, tworząca się na ziarnach błona biologiczna miała strukturę bardziej zwartą i później osiągała grubość czyniącą ją podatną na zrywające działanie strumienia wody. Przy niższej prędkości filtracji błona biologiczna miała większą grubość. Stwierdzono także, że powtarzającym się w trakcie cyklu filtracyjnego zjawiskom odrywania błony i zmniejszenia jej grubości towarzyszył wzrost zużycia tlenu powyżej wartości wynikającej ze stechiometrii reakcji nitryfikacji.
EN
The study was carried out using a physical model of a rapid filter with a biologically active sand bed. The filtration cycles tested involved two velocities: 5 m/h and 10 m/h, water temperature being set to 15. It was found that with the extension of the filtration time ammonia nitrogen was periodically removed with a lower oxygen uptake than the one resulting from the stoichiometry of the nitrification reaction. And this indicates that, besides nitrification, there is a concurrent process where ammonia nitrogen is assimilated by nitrifying and heterotrophic bacteria. The experiments revealed that at the filtration velocity of 10 m/h biofilm growth was slower. This is attributable to the continuing detachment of a certain portion of the heterotrophic organisms, on one hand, and to the slower growth rate of nitrifying bacteria that are characterized by a higher resistance when exposed to the water stream, on the other hand. As a result, owing to an increased filtration velocity and a lower oxygen uptake than the one resulting from the stoichiometry of the nitrification reaction, the biofilms growing on the grain surface developed a more compact structure and thereafter reached a thickness that reduced their inherent resistance to the influence of the water stream. At a lower filtration velocity, the biofilm grew thicker. It was also found that the recurrent phenomena of biofilm detachment and reduction in biofilm thickness (observed during the filtration cycle) were concomitant with a rise in oxygen uptake to a value higher than the one resulting from the stoichiometry of the nitrification reaction.
EN
This paper deals with the design and validation at laboratory scale of biotechnological processes efficient in terms of performances and reduction of environmental impact of the mining and processing of black shale ores (BIOSHALE project).
PL
Przedstawiono wyniki bioługowania, w skali laboratoryjnej, rudy czarnego łupka ze złoża Talvivaara (Finlandia) w różnych układach technologicznych.
18
Content available remote Chitinolytic bacteria in two lakes of different trophic status
EN
This paper presents the results of research on the number of chitinolytic bacteria and chitinolytic activity of strains in the oligo-mesotrophic and the eutrophic lakes. Two lakes of soft and hard water and of different trophic status (in terms of nutrients contents) from Iławskie Lake District (North Poland) were choosen. The numbers of chitinolytic bacteria were higher in eutrophic lake (average 1.0 x 10^3 cells cm^-3) than in oligo-mesotrophic lake (average 0.5 x 10^3 cells cm^-3) as well as in littoral versus pelagic zone. However, a higher percentage of chitinolytic bacteria (average 13%) among the total numbers of heterotrophic bacteria was found in oligo-mesotrophic lake as well as higher rate of the chitinolytic activity of bacteria (7.0 versus 4.5 nmol GlcNAc mg^-1 protein h^-1 after 6 days of incubation). The possible shortage of dissolved organic compounds in mesotrophic lake was pointed up as the reason for using the dissolved chitin as the source of carbon and nitrogen. Enterobacter aerogenes (28%), Aeromonas sp. (25%) and Chromobacterium sp. (16%) dominated in oligo-mesotrophic lake. In eutrophic lake, the most numerous species were Aeromonas hydrophila (46%) and Aeromonas sp. (15%).
19
Content available remote Isolation of bacteria that degrade organometallic compounds from metallic wastes
EN
In this report we describe the isolation and identification procedure for heterotrophic bacteria found in wastes from Polish copper mines. The identification procedures included microscopic investigations, and metabolic tests API50CHB and ID32GN.
PL
W pracy przedstawiono sposób izolacji bakterii heterotroficznych z odpadów poflotacyjnych, pochodzących z osadników polskiego okręgu miedziowego oraz metodykę ich identyfikacji na podstawie badań mikroskopowych, własności metabolicznych i testów identyfikacyjnych ID32GN, API50CHB przeprowadzonych na mini analizatorze API.
20
Content available remote Characteristics of biofilm growing in moving-bed biofilm system
EN
Biofilm was tested in the last phase of an experiment in a system with moving-bed biofilm carriers. The experiment was carried out in order to examine an integrated nitrogen and carbon removal. In every reactor of the system, the biofilms differed, both in their physical properties and microbiological composition. The biofilm thickness ranged from 50 to 300 žm. The most numerous bacteria fraction in the biomass were heterotrophs which dominated in all the reactors and constituted from 90.9% to 99.9% of active bacteria population. In the active bacteria population, there were at most 0.8% of nitrifiers.
PL
Badania biofilmu przeprowadzono w ostatniej fazie eksperymentu zintegrowanego usuwania azotu I węgla z ruchomymi nośnikami biomasy. Biofilm w każdym reaktorze układu był inny zarówno ze względu na własności fizyczne, jak i skład mikrobiologiczny. Jego grubość zmieniała się w granicach od 50 do 3000 žm. Najbardziej liczną grupą bakterii w biomasie były bakterie heterotroficzne, które dominowały we wszystkich reaktorach i stanowiły od 90,9% do 99,9% populacji bakterii aktywnych. Bakterie nitryfikacyjne stanowiły, co najwyżej 0,8% populacji bakterii aktywnych.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.