Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 17

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  heat pipes
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
All important parameters of LED light sources depend strongly on temperature of semiconducting materials. Durability and efficiency of mentioned devices decrease dramatically in the function of temperature. According to thermal generation of current carriers, also electrical parameters (like dynamic resistance of the diode) varies with junction temperature. In some cases, such phenomena can provide a very fast degradation of LED by means of overheating or by exceeding maximal current of the diode. Basing on such reasons, heat dissipation systems, seems to be a very important equipment of semiconducting light sources. All solutions presented in the paper are connected with automotive solutions, where limited space of heat dissipation system is a very important factor. Due to this feature, selected types of heat sinks equipped with heat pipes, were analyzed and described in the paper. Methods for analysis of such devices were presented and some Author's procedures for effective determination of temperature distribution were described. Accuracy of proposed solutions were compared to test results of physical models. Efficiency of heat pipes heat sinks was compared to classical heat dissipation systems in natural convection conditions.
PL
stotne parametry eksploatacyjne diod elektroluminescencyjnych istotnie zależą od temperatury. Zarówno trwałość, sprawność, jak i parametry elektryczne (jak rezystancja dynamiczna diody) zmieniają się w funkcji temperatury złącza, co prowadzić może do szybkiej degradacji LED'ów wynikającej z przegrzania lub przekroczenia granicznej wartości prądu (w przypadku stosowania źródeł napięciowych). Z uwagi na opisane czynniki, poprawna konstrukcja elementów rozpraszających ciepło jest szczególnie istotna w źródłach o znaczących mocach. Rozwiązania prezentowane w niniejszym artykule dotyczą źródeł światła stosowanych w pojazdach, gdzie ograniczone rozmiary wymuszają poszukiwania najbardziej efektywnych sposobów rozpraszania ciepła. W pracy scharakteryzowano radiatory wyposażone w rurki cieplne. Podano metody analizy tego typu układów oraz autorskie rozwiązania pozwalające na efektywne obliczenia rozkładu temperatury. Sprawność radiatorów wyposażonych w rurki cieplne porównano z klasycznymi w warunkach charakterystycznych dla eksploatacji w maszynach roboczych.
EN
Limiting the temperature of exhaust gases to below 150°C is one of the necessary conditions for diesel engine to be used in a potentially explosive atmosphere. For this purpose heat exchangers are necessary to be used. This article presents the concept of exchanger in which heat pipes are used to transport thermal energy from the exhaust gases to the cooling medium.
EN
Heat pipes transfer heat at a minimum temperature difference between evaporating and condensing phase. Operating temperature of heat pipe is determined by working fluid and vacuum achieved during production. This paper is focused on determining the effect of initial temperature of ambient air to the performance characteristics of produced heat pipes. In general, a decrease in pressure decreases the boiling liquid. Based on this it can be presumed that achieving a lower temperature during production of heat pipe, the lower vacuum, while the boiling point working fluid while increasing ability to heat transport.
EN
The paper presents and analyzes new type air heater, which uses the thermosyphon’s technology, aims to replace the existing horizontal tubular air heater of first-degree for steam generators Nos.5,6,7 and 8 at TPP Maritsa East-2 in Bulgaria. The main advantage of the air heater with heat pipes is the ability to lower the temperature of exhaust gases to levels that are impossible for the conventional tubular air heaters, thus increasing the efficiency of the steam generator. Along with the increased energy efficiency, reductions in CO2, SOx and NOx emissions into the atmosphere are achieved. The preheating of the air, used for air combustion by recirculation relieving the operation and improving the combustion in the steam generator, is also reduced.
EN
The choice of rational heat-utilizer heating scheme is a very current problem of energy saving when using boiler units. This article proposes the heat computation technique of heat exchanger at heat pipes with deep combustion - product cooling in boilers and water steam condensation. In addition, the construction scheme of heat exchanger made with two units in which the heat pipes are filled with different working medium is described. The numerical study results of heat carrier temperature and pressure distribution, namely: combustion products and water being heated according to counterflow - heat exchanger length are presented. The efficiency of two-phase heat-utilizer is determined.
PL
Geotermalne pompy ciepła są układami pobierającymi niskotemperaturowe ciepło zawarte w gruncie kosztem dostarczanej mocy elektrycznej. Dodatkowa moc pozwala na podwyższenie temperatury w obiegu na żądany poziom (np. potrzebny do przygotowania c. w. u.) Tradycyjnym rozwiązaniem pobierania odnawialnej energii z gruntu jest wykonanie pionowych odwiertów na głębokość 50-200 m i umieszczenie w nich kolektorów w formie u-rurek. Płynący w kolektorze czynnik pobiera ciepło, wiąże się to jednak z dodatkowymi kosztami energii zużywanej przez pompy obiegowe wymuszające ruch czynnika. Zastosowanie rurki ciepła zamiast tradycyjnego kolektora pozwala na obniżenie kosztów pracy układu poprzez wyeliminowanie pracy pomp obiegowych. Zasadność tego rozwiązania będzie oceniona w artykule pod względem energetycznym i ekonomicznym.
EN
Geothermal heat pumps are systems extracting low-temparture heat from the ground. Addtionall electical power is needed to raise the temperature level in heat pipe cycle (e. g. required for domestic hot water preparation). Traditional technical solution for absorbing ground energy is drilling 50-200 m deep boreholes with vertical collectors (U-shaped pipes)in them. Working fluid flows in collector pipes and draws heat from the ground, however it raises overall costs by the price of energy used by circulation pumps. Aplication of heat pipe instead of traditional vertical collector reduces overall costs of operation of heat pump system by eliminating additional pumping power for working fluid circulation. Economic and energetic rationale for applying this improved system will be discussed in this paper.
PL
W artykule przedstawiono podstawowe informacje o rurkach ciepła, opis stanowiska i metodykę realizowania pomiarów intensywności przekazywanego przez nie ciepła oraz wyniki zrealizowanych badań.
EN
The basic information on heat pipes, a description of laboratory stand-up together with description of research of heat transfer intensity as well as obtained results have been presented in this paper.
8
Content available remote Rurki ciepła - zasada działania, budowa, zastosowania
PL
W artykule przedstawiono zasadę działania rurek ciepła, ich odmiany konstrukcyjne, zakres stosowalności oraz przegląd zastosow
EN
The principle of operation, the construction types, the range of use as well as a large review of possible applications of het pipes has been presented in this paper.
PL
Artykuł dokumentujący kolejny etap prac poświęconych zagadnieniom skojarzonej produkcji energii cieplnej i elektrycznej za pomocą mikrosiłowni ORC, czyli produkcji dla pokrycia potrzeb indywidualnego odbiorcy. Jednym z głównych problemów w konstrukcji takiego urządzenia jest wysokosprawny wymiennik ciepła, stanowiący integralną część obiegu parowego ORC. Wymiennik ten winien charakteryzować się wysoką wydajnością cieplną osiąganą przy niedużych gabarytach i małej masie. W artykule przedstawiono unikalną konstrukcję wymiennika płaszczowo-rurowego wyposażonego w minirurki, którego prototyp był przedmiotem badań cieplnych w układzie woda-woda, a następnie w układzie olej grzewczy-etanol. Wyniki tych badań stanowią zasadniczy element tej publikacji
EN
The paper reports a part of research and development works on cogeneration ORC micro power plant for an individual user. One of the main tasks is to design a high effciency heat exchanger for the system. It has to attain high capacity with small dimensions and mass. The special design of shell and micro-tubes heat exchanger is described. The results of experimental tests of water to water and iol to methanol heat transfer are presented.
PL
W artykule przedstawiono wpływ struktur porowatych stosowanych w rurach cieplnych poziomych oraz czynników roboczych na ich wydajność cieplną. Opisano podstawy teoretyczne związane z działaniem tych urządzeń. Przedstawiono modele matematyczne opisujące ich pracę.
EN
The paper includes theoretical explanations for the basic phenomena and process dealt with in heat recovery with use of heat pipes. The theoretical basics for thermosyphons and capillary heat pipes were described. The most commonly used capillary wick structures with work formula and were described. On the basis of charts work characteristics for different factors used in thermosyphons and capillary heat pipes were presented. The mathematical models for heat transfer in heat pipes were presented, model has been proposed on the basis of e–NTU model.
EN
In the 21st century the way to increase the efficiency of new sources of energy is directly related with extended exploration of renewable energy. This modern tendency ensures the fuel economy needs to be realized with nature protection. The increasing of new power sources efficiency (cogeneration, trigeneration systems, fuel cells, photovoltaic systems) can be performed by application of solid sorption heat pumps, regrigerators, heat and cold accumulators, heat transformers, natural gas and hydrogen storage systems and efficient heat exchangers.
PL
Druga część publikacji poświęconej rurce ciepła (heat pipe), w której autor przedstawia wybrane jej zastosowania. W części pierwszej (nr 3/2009 .TCHK' ) omówiona została budowa i zasada działania rurki grawitacyjnej i rurki z tzw. knotem. Sporo uwagi poświęcono regulacji wydajności rurki ciepła, podane zostaly również przykłady charakterystyk cieplnych rurek jednego z producentów oraz zasady, jakimi należy się kierować dokonując ich doboru. W części drugiej znajdujemy przykłady praktycznego zastosowania i wykorzystania tego elementu, a są to: wymienniki w blokach odzysku ciepła urządzeń wentylacyjnych i klimatyzacyjnych, zastosowanie do regulacji temperatury gruntu (np. linia kolejowa do Tybetu), do podgrzewania powierzchni wiaduktów i mostów, w systemach chłodzenia podzespołów elektronicznych i w wielu innych aplikacjach praktycznych.
EN
In the first part (nr 3/2009 'TCHK'] the design and operation of gravitational heat pipe and heat pipe with a wick were described. Capacity regulation methods and heat pipes characteristics were presented. The second part deals with examples of practical heat pipes applications in ventilating heat recovery units, in systems for ground temperature regulation (ex. railway to Tibet), for bridge heating, for cooling of electronic devices and many others.
PL
Pierwsza część publikacji poświęconej rurce ciepła ( heat pipe ), w której autor prezentuje budowę i zasadę działania dwóch zasadniczych jej rodzajów: rurki grawitacyjnej i rurki z knotem. Zwraca uwagę na możliwy zakres temperatur jej pracy, od temperatur kriogenicznych do temperatur wysokich sięgających 2000°C oraz stosowane w tych zakresach płyny robocze. W artykule omówiono również budowę i strukturę knota. Sporo uwagi poświęcono regulacji wydajności rurki ciepła, którą można realizować z wykorzystaniem gazu inertnego, poprzez nadmiar ciekłego czynnika zalewającego część skraplającą lub za pomocą zaworu dławiącego. Podane zostały przykłady charakterystyk cieplnych rurek jednego z producentów oraz zasady, jakimi należy się kierować dokonując ich doboru. Część druga artykułu poświęcona będzie przykładom praktycznego zastosowania i wykorzystania tych urządzeń.
EN
This is the first part of the series of papers dealing with heat pipes. Two kind of heat pipes have been discussed in the paper: gravitational one and with a wick. The wide range of application was emphasized: from criogenics up to 2000°C along with the appropriate working fluids. The design and structure of the wick have been described. Control of heat capacity of the heat pipe by means of inert gas, overload of liquid refrigerant or by application of the throttling vallve have been discussed. Exemplary thermal characteristics of heat pipes of the exemplary manufacturer as well as the principles of the choice of heat pipe have been presented. The second part of the paper will be dealing with exemplary practical applications of these devices.
PL
Rurki ciepła stanowią bardzo wygodny element efektywnej regulacji termicznej. Są stosowane jako wymienniki ciepła w urządzeniach chłodniczych, pompach ciepła, urządzeniach do odzysku ciepła w systemach wentylacji mechanicznej i klimatyzacji. Istotne znaczenie mają tutaj współczynniki przejmowania ciepła, zarówno dla strefy skraplacza, jaki strefy parownika. Wartości tych współczynników mieszczą się w zakresie 103+105 W/m2K i są znacznie korzystniejsze niż w klasycznych wymiennikach ciepła. Dlatego też, wymienniki zbudowane na bazie rurek ciepła, mogą mieć mniejszą powierzchnię wymia-ny ciepła i mniejszą masę, dlatego też znalazły szerokie zastosowanie w urządzeniach związanych z najnowocześniejszymi technologiami wykorzystującymi podzespoły elektroniczne. W pracy przedstawiono podstawowe typy rurek ciepła, omówiono ich konstrukcję, sposób działania i podstawowe parametry termiczne. Zwrócono uwagę na praktyczne zastosowania rurek ciepła różnych typów w chłodniczych i klimatyzacyjnych wymiennikach ciepła.
EN
Heat pipes are very flexible systems with regard to effective thermal control. They are used as heat exchangers in refrigerat-ing systems, heat pumps, heat recovery systems for ventilation and air-conditioning. Their heat transfer coefficients are very important for condenser unit as well as for evaporator. Values of the coefficient are in the range 103+105 W/m2K and are much better that for classic heat exchangers. For these reasons heat exchangers with heat pipes could have smaller heat trans-fer area and smaller mass. They have wide application in devices using electronic systems. This work reviews basic types of heat pipes, construction and describes working methods and fundamental thermal parameters. Special attention was taken on practical application of heat pipes in heat exchangers of refrigeration systems and air-conditioning units.
PL
W artykule przedstawiono najczęściej stosowane metody odbioru ciepła z procesorów komputerowych — zasadę ich działania, wady i zalety, oraz zastosowania. Pierwsze z nich, jako historycznie najstarsze, to urządzenia oparte wyłącznie na chłodzeniu powietrzem. Omówiono również chłodzenie za pomocą obiegów cieczy oraz zastosowanie technologii ciepłowodów. Przedstawiono także ogniwo Peitiera, które zapewne będzie stosowane w przyszłości. Porównano wydajność i emisję hałasu różnych systemów chłodzących.
EN
The most frequently used methods of heat reception from a computer processor, their working principles, advantages and disadvantages as well as applications arc presented in the paper. The oldest methods were solely based on air cooling. The up-to-day methods based on cooling liquid circulation and heat pipes technology are then discussed. In the end. the Peltier fuel cell is introduced as the most promising solution. Capacity and emission of noise for various cooling systems are also compared.
PL
Przeanalizowano znaczenie przewodnictwa cieplnego, w ustalaniu się czasu schładzania lub mrożenia oraz odchładzania/rozmrażania/produktów spożywczych. Rozpatrzono możliwości jego skrócenia poprzez zastosowanie rur ciepła.
EN
The importance of thermal conductivity in stabilization chilling, freezing and thawing time was analyzed in this paper. The possibility to reduce process parameters in those processes by application of heat pipes is considered.
EN
Modern thermal control systems for the electronic cooling are considering such as heat pipes and two-phase thermosyphons for low, middle and high power electronic elements. Thermally driven sold sorption system are discussed as an emergency cooling possibility for the future cooling of electronics.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.