Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 85

Liczba wyników na stronie
first rewind previous Strona / 5 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  drenaż
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 5 next fast forward last
2
Content available remote Taras na gruncie – specyficzny rodzaj okapu. Studium przypadku
PL
W artykule omówiono kwestie projektowania tarasów na gruncie. Omówiono materiały stosowane do izolacji zarówno poziomych, jak i pionowych. Na ilustracjach pokazano warstwy i okap tarasu na gruncie z posadzką z płytek, a także tarasu na gruncie z drenażowym odprowadzeniem wody.
EN
The article discusses the issues of designing terraces on the ground. Materials used for both horizontal and vertical insulation are discussed. The illustrations show the layers and eaves of a terrace on the ground with a tile floor, as well as a terrace on the ground with drainage.
3
Content available remote Systemy tarasów wentylowanych – wybrane zagadnienia
PL
Autor omawia systemy tarasów z drenażowym odprowadzeniem wody pod kątem wymagań projektowo-wykonawczych. Tłumaczy takie zagadnienia jak wybór podstawek dystansowych, hydroizolacja i termoizolacja tarasów oraz wykończenie okapu.
EN
The author discusses terrace systems with drainage systems in terms of design and implementation requirements. He explains issues such as the selection of spacers, waterproofing and thermal insulation of terraces and eaves finishing.
EN
The purpose of this study concerns the establishment of numerical model of transient flow in a variably saturated porous medium. Groundwater flow can only be studied adequately if one considers the fluxes between the saturated and the unsaturated zones through the free surface. However, this water table undergoes variations in level resulting either from losses of mass by gravity drainage or evaporation or from an excess of mass by infiltration from the surface of the porous medium. This describes the various phenomena that groundwater flow can undergo, such as gravity drainage, infiltration and evaporation. The adopted model is based on the Richards equation, which is a parabolic and strongly non-linear equation. The h-based form of the Richards equation is solved numerically by using the 1D upwind finite difference method. Referring to published experimental work and comparing our numerical results with their results, we have obtained a good fit. The importance of this model lies in its simplicity and its generality in treating the different flow states in a variably saturated porous medium, and therefore its usefulness in practice for a wide range of applications, contributing significantly to the understanding of transient flow phenomena in variably saturated porous media. Its capacity to address the complexities of groundwater movement, including gravity-driven drainage, infiltration, and evaporation, underlines its versatility and its potential to make meaningful contributions to various scientific and engineering fields.
5
Content available remote Osuszanie zabytkowych murów fundamentowych metodą drenażu dwufunkcyjnego
PL
Bardzo trudna jest ochrona zabytkowych budowli posadowionych na masywnych fundamentach przed wilgocią gruntową. Dotychczas stosowane metody są zawodne, a podejmowane działania niejednokrotnie przynoszą odwrotny efekt. Zachodzi zatem potrzeba poszukiwania nowych, bardziej skutecznych i mało inwazyjnych sposobów ochrony budowli przed wodą gruntową. W artykule przedstawiono wdrażaną obecnie autorską metodę drenażu dwufunkcyjnego, która polega na rozdzieleniu komina filtracyjnego na strefę osuszającą i odwadniającą. Umożliwiają to materiały najnowszej generacji, np. wodoszczelne i jednocześnie paroprzepuszczalne membrany separujące złoże osuszające.
EN
It is very difficult to protect historic buildings set on massive foundations against ground damp. The methods used so far are unreliable, and the taken actions often bring the opposite effects. Therefore, there is a need to search for new, more effective and minimally invasive methods of protecting structures against groundwater. The article presents the proprietary dual-purpose drainage method that is currently being implemented. The method consists on separating the filter zone (chimney) into a drying and drainage zone. It is possible thanks to the newest materials, such as waterproof and, at the same time, vapor-permeable membranes separating the drying bed.
6
PL
W artykule omówione zostały różnego rodzaju systemy i technologie służące do odprowadzenia wody z tarasów i balkonów. Autor omawia bardzo szczegółowo dostępne na rynku rozwiązania. Opisuje je i przedstawia wymogi techniczne, jakie należy spełnić przy ich zastosowaniu. Podaje szereg porad związanych z wykonawstwem tych systemów.
EN
The article discusses various types of systems and technologies for draining water from terraces and balconies. The author discusses the solutions available on the market in great detail. He describes them and presents the technical requirements to be met when using them. He provides a number of tips related to the implementation of those systems.
PL
W artykule przedstawiono możliwości i zalety zastosowania betonu wodoprzepuszczalnego jako komunikacyjnych nawierzchni przepuszczalnych, podbudów drogowych czy też wodoprzepuszczalnych konstrukcji oporowych. Wskazano wymagane ich właściwości w celu zapewnienia prawidłowej pracy jako warstw odwadniających lub ochronnych konstrukcji, przy jednoczesnym spełnieniu kryteriów nośności i trwałości. Stały się one podstawą do zaproponowanej procedury projektowania betonu, wyznaczającej obszar dopuszczalnego uziarnienia możliwego do zastosowania kruszywa oraz stopnia wypełnienia go zaczynem.
EN
The article presents the possibilities and advantages of using water-permeable concrete as communication permeable surfaces, road foundations or water-permeable retaining structures. Their required properties are indicated in order to ensure proper operation as drainage or protective layers of structures, while meeting the criteria of load-bearing capacity and durability. They became the basis for the proposed concrete design procedure, determining the area of acceptable granularity of the aggregate that can be used and the degree of filling it with grout.
EN
Mine drainage pump is the most important load in mining which requires high reliability when operating. Currently, the power supply of a mine drainage pump is connected to the same power line with many nonlinear loads, and is equipped with power electronic converters, which makes the power supply nonsinusoidal. During the working process of a mine drainage pump, the load-carrying factor often changes, and many types of failures occur, among which single-phase voltage loss is the most common problem. In the case of a nonsinusoidal power supply, if a single-phase voltage loss occurs in different load modes, it will greatly affect the working mode of the mine drainage pump leading to influences on the working efficiency, the life of the pump, and sometimes it is necessary to recalculate the protection parameters. This paper studies the influence of single-phase voltage loss and load carrying mode on the working mode of mine drainage pump motor in case the of nonsinusoidal power supply. Research results show that, in the case of nonsinusoidal power supplied with single-phase voltage loss, copper losses in the rotor and stator circuits increase with increases in voltage total harmonic distortion (THD) and load-carrying factor, 5th order reverse harmonic increases copper loss in asynchronous motor the most, and higher harmonic components have less effect on copper loss in the motor. At the same time, the speed ripple decreases with the increase of the motor load factor and decreases in the presence of the 5th order negative sequence harmonic, and increases significantly in the presence of the 7th order positive sequence harmonic. 5th order negative sequence harmonic increases, the torque ripple increases, while the 7th order positive sequence harmonic reduces the torque ripple in the case of single-phase voltage loss. The results of the paper will help improve the operational efficiency of the mine drainage pump in Vietnam's mines.
EN
The objective of the undertaken investigations was to examine in laboratory conditions whether an introduction of an assisting opoka rock layer with the granulation of 1–6 mm into the ground improves the removal efficiency of nitrogen and phosphorus compounds from domestic sewage. The performed investigations concerned the layer supporting the removal efficiency of domestic sewage in a home sewage treatment plant under infiltration drainage. The model investigations of wastewater purification were carried out in a medium sand bed with an assisting, 0.10 and 0.20 m thick opoka rock layer. The effectiveness of wastewater purification related to basic qualitative indicators (total suspended solids – TSS, BOD5, COD, total nitrogen, total phosphorus) was in line with the Polish standards on sewage disposal into grounds and surface water. The medium sand soil bed with the 0.20 m thick assisting opoka rock layer showed higher effectiveness of wastewater purification than that 0.10 m thick. The application of the 0.20 m thick opoka rock layer increased the removal efficiency regarding TSS by 6.2%, total nitrogen by 20.4%, ammonium nitrogen by 8.3% and total phosphorus by 2.9%, and removal efficiency regarding BOD5 by 1.2% and COD by 1.9% with relation to the 0.10 m thick assisting layer (all percentages − in average). The results confirm that the natural opoka rock with the granulation of 1–6 mm can be used to assist in the removal of nitrogen and phosphorus compounds from wastewater with the application of infiltration drainage.
PL
W artykule przedstawiono rozwiązanie konstrukcyjne przydomowej oczyszczalni ścieków z drenażem rozsączającym, którą można wybudować na stoku wzniesienia. Podano zalecenia dotyczące budowy i zakresu jej zastosowania oraz zalecenia projektowe.
EN
The article presents a construction solution for a household sewage treatment plant with infiltration drainage, which can be built on a hillside. The article contains recommendations on the construction and scope of its application as well as design recommendations.
PL
W artykule przedstawiono przykład skutecznego, stałego odwodnienia południowego przyczółka wiaduktu drogowego w ciągu drogi krajowej nr 7 (DK7) nad drogą S7 w rejonie Rychnowskiej Woli, który był wykonywany w warunkach napiętego zwierciadła wody gruntowej. Zaprojektowany, a następnie wykonany system drenażowy na etapie realizacji pozwolił na przeprowadzenie dalszych robot, a obecnie zapewnia bezpieczną eksploatację budowli. Pozostałe problemy geotechniczne związane z wodą naporową oraz swobodną rozwiązane w trakcie realizacji tego odcinka drogi ekspresowej S7, którego element stanowił drenaż przyczółka południowego (P1), opisano w nr. 3/2020 „Magazynu Autostrady”.
EN
The article presents an example of a permanent drainage of the southern abutment of the road viaduct along the DK7 road over the S7 road in the area of ​​Rychnowska Wola, which was carried out under the conditions of groundwater pressure. The designed and then constructed drainage system enabled further works and ensured a safe service of the structure. Other geotechnical problems related to groundwater pressure and free water resolved during the construction of this section of the S7 expressway are described in „Magazyn Autostrady” no. 3/2020.
PL
Jednym z problemów, który wymaga rozwiązania na etapie przygotowania i realizacji inwestycji drogowych, jest woda gruntowa na odcinkach zlokalizowanych w wykopach. Może występować w postaci zwierciadła swobodnego, co objawia się sączeniami i wypływami ze skarp i/lub w postaci zwierciadła napiętego, uniemożliwiającego realizację robót lub prawidłową eksploatację z uwagi na przebicia i wypływy przez warstwy podłoża gruntowego nawierzchni. W artykule przedstawiono przekład zrealizowanego odcinka drogi ekspresowej S7 w głębokim wykopie ze swobodnym i z napiętym zwierciadłem wody gruntowej, stabilizującym się powyżej niwelety.
EN
One of the problems that needs to be solved at the stage of the preparation and implementation of road investments is groundwater at the sections of roads constructed in trenches. The effects of high groundwater level are excessive seepage pressure and the erosion of slopes, which can render the completion and service of roads impossible due to hydraulic failure and outflows of water through the layers of the pavement subsoil. The article presents an example of the completed section of the S7 expressway constructed in a deep trench with the groundwater level and piezometric pressure stabilization above the road surface.
PL
Zagadnienie zagospodarowania wód opadowych i gruntowych w rejonie konstrukcji drogowych i kolejowych stanowi istotny element bezpiecznej i efektywnej eksploatacji tych obiektów. Odpowiednie wykorzystanie geokompozytów drenażowych zapewnia bezproblemową pracę konstrukcji oraz właściwą ochronę przed uszkodzeniami wynikającymi z niekontrolowanego oddziaływania wody.
EN
The issue of rainwater and groundwater management within ​​road and railway structures is an important element of the safe and effective operation of this particular infrastructure. The appropriate use of drainage geocomposites ensures trouble-free service of a structure and adequate protection against damage due to uncontrolled exposure to water.
PL
Leca® KERAMZYT to lekkie ceramiczne kruszywo wykorzystywane w bardzo wielu różnorodnych izolacjach w budownictwie. Drobno- i średnioziarnisty keramzyt jest podstawowym składnikiem przy produkcji betonów lekkich, pustaków i bloczków. Natomiast gruboziarniste kruszywo wykorzystywane jest między innymi do wypełnień i izolacji termicznych, drenaży, podłóg na gruncie, stropodachów, w budownictwie drogowym na gruntach o niskiej nośności. W ostatnich latach keramzyt coraz częściej układa się w remontowanych stropach. Ciężar kruszywa ok. 300 kg/m3 pozwala na zdecydowane odciążenie konstrukcji stropu, przedłużając ich techniczną sprawność. W przypadku nowych realizacji keramzyt można znaleźć jako materiał drenażowy i retencjonujący wodę w konstrukcjach dachów zielonych i dachów użytkowych.
19
Content available remote Funkcja drenażowa geosyntetyków
PL
Spośród wielu funkcji geosyntetyków, które powszechnie znajdują zastosowanie w budownictwie, jedną z istotniejszych jest funkcja drenażowa. Zapewnienie długotrwałego, niezawodnego funkcjonowania drenażu wymaga przyjęcia odpowiedniego geokompozytu drenażowego.
EN
The article presents the current state of knowledge in the field of estimating preliminary values of storm water subcatchment calibration parameters in the case of using the Storm Water Management Model (SWMM) for building a model of storm water drainage system. The key issue is estimating the runoff width in the case of reducing the network structure and storm water catchments due to the shortening of calculation time and simplification of the model calibration process. Correction of one of the recommended literature methods has been proposed. The assessment was based on the real catchment model with single and multi-family housing. It was found possible to apply the proposed method in the case of reducing systems connected in series.
first rewind previous Strona / 5 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.