Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 23

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  cooler
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
Motor coolers are operated with the coupling of temperature and pressure fields, in which the change rule is affected by multiple factors. In this study, the thermal resistance of the motorcooler was examined using the velocity coefficient method to reveal the influence of heat transfer and wind resistance. The temperature and pressure fields were analyzed using the finite element method based on the hydrodynamics and momentum theorem. By varying the heat transfer and wind resistance coefficients to reflect temperature and pressure characteristics, wind and water velocities were determined. Results demonstrate that the total convective heat transfer and wind resistance coefficients of the cooler model are sensitive to variations in face-to-face wind velocity, but not to those of the cooling water flow rate. When wind velocity increases from 0.8 to 5.19m/s, the total convective heat transfer increases by 1.85 times and wind resistance increases by 18.74 times. Variations in cooling water velocity has little effect on the Nusselt numberon the air side and the Euler number of the single row tube, which are multiplied with the increase of the Reynolds number. When the Reynolds number increases from 1020 to 6345, the Nusselt number increases by 2.05 times and the Euler numer decreases by 2.29 times. The results provide references for the design and performance testing of high-power motor coolers.
PL
Instalacja chłodzenia budynku odgrywa kluczową rolę w zapewnieniu warunków komfortu cieplnego w pomieszczeniach w okresie letnim. Stanowi ona jednocześnie dominujący element, który wpływa na zużycie nośników energii przez budynek. Powyższe stwierdzenia rodzą potrzebę optymalizacji parametrów pracy tej instalacji w fazie jej projektowania. Wykorzystując wyniki rozważań przeprowadzonych we wcześniejszych opracowaniach [4], [5], [6], [7] oraz doświadczenia praktyczne, autor artykułu przedstawił własny punkt widzenia na takie zagadnienia, jak wyznaczanie temperatury wody zasilającej chłodnice w systemie z klimakonwektorami wentylatorowymi na podstawie analizy charakterystyki cieplnej pomieszczeń, wymiarowanie klimakonwektorów wentylatorowych spełniających wymagania cieplne pomieszczeń oraz na podstawie parametrów tych urządzeń podawanych na stronach katalogowych przez producenta (lub Eurovent). W artykule zwrócono także uwagę na wpływ sposobu regulacji wydajności chłodnicy na współczynnik kierunkowy przemiany uzdatniania powietrza. Poniższy artykuł stanowi komplementarne uzupełnienie artykułu zamieszczonego w numerze lutowym COW [4].
EN
The installation of a building’s cooling system plays a key role in ensuring indoor thermal comfort conditions during the summer. At the same time, it is the dominant element that influences the building’s energy consumption. The statements above create a need to optimize the operating parameters of this installation at the design stage. The author of the article presents his own point of view on such issues by using the results of considerations carried out in earlier studies [4], [5], [6], [7] and practical experience as determining the temperature of water feeding coolers in the system with fan coil units on the basis of the analysis of thermal characteristics of rooms, dimensioning of fan coil units meeting the thermal requirements of rooms, and on the basis of the parameters of these units given on the catalogue pages by the manufacturer (or Eurovent).The article also points out the influence of the cooler efficiency regulation method on the directional coefficient of air treatment conversion. The article below is a complementary supplement to the article included in the COW number [4].
3
Content available remote Problemy związane z wysoką temperaturą klinkieru podczas produkcji cementu
PL
Zbyt wysoka temperatura klinkieru, w szczególności wyższa od 70°C, powoduje pewne trudności w produkcji cementu, pogarsza jego jakość i prowadzi do zbrylania materiału w silosie. Aby zapobiec tym problemom należy stosować specjalne zabiegi technologiczne dążące do uzyskania klinkieru o odpowiednim składzie granulometrycznym. W przypadku niewystarczającego wychłodzenia klinkieru w chłodniku, należy zastosować wtrysk wody do chłodnika lub do urządzeń transportujących klinkier. Wtrysk wody do młyna w ilości powietrza służącego do przewietrzania młyna również daje dobre rezultaty. Dodatkowo korzystne jest częściowe zastąpienie gipsu anhydrytem, w młynie lub silosie. Znacznie lepszym rozwiązaniem jest instalacja chłodnika do cementu, niż ponoszenie konsekwencji jego wysokiej temperatury.
EN
Too high clinker temperature, especially above 70°C, causes several difficulties in cement production, lowers its quality and leads to lumping of the material in the silos. To avoid these difficulties the appropriate clinker granulometry trough special technological treatment, should be obtained. In the case of insufficient cooling in the cooler the water spraying into the cooler or on clinker transporting devices is to be employed. Water injection into the mill as amount of ventilation air give also good results. Finally the partial substitution of gypsum by anhydrite in the mill or in silos. It is much better to install the cement coolers than to carry the consequences of high cement temperature.
PL
Publikacja, której celem jest przedstawienie schematu tworzenia modelu parownika zasilanego ciśnieniowo o określonej budowie, wielkości oraz powierzchni wymiany ciepła, będącego częścią składową wentylatorowej chłodnicy powietrza jako istotnego elementu konstrukcji powietrznej, sprężarkowej pompy ciepła. Na podstawie danych projektowych oraz wyników wykonanej optymalizacji został stworzony Model 3D wymiennika w programie SolidWorks w celu przedstawienia i zobrazowania jego geometrii. W części drugiej tej publikacji przedstawiony model będzie podstawą do analizy pracy tego wymiennika przy różnych parametrach.
EN
The aim of this paper is to describe the modeling process for direct expansion evaporator with specific design and heat transfer area as a very important part of an air cooler in a compressor heat pump. Based on project data and optimization process the 3D model of the heat exchanger is created with the use of SolidWorks software in order to show its geometry. In the second part this model will be used for the heat exchanger operation analysis with different working parameters.
PL
W nawiązaniu do wcześniej publikowanego w „TCHiK” artykułu Mikołaja Klenkiewicza, prezentowana publikacja stanowi kontynuacją zapoczątkowanego wówczas tematu. Autor postawił sobie za cel udzielenie odpowiedzi na pytanie, w jaki sposób ten proces zoptymalizować? Przedmiotem oceny jest proces odszraniania przy pomocy gorącego gazu (gorących par czynnika) w warunkach komory mroźniczej z parownikiem podsufitowym.
EN
This is a continuation of the subject of defrosting process. The paper deals with optimization of defrosting by the use of hot gas for under-roof evaporator inside a low temperature cold room.
PL
Celem publikacji jest udzielenie odpowiedzi na pytanie, w jaki sposób zoptymalizować proces odszraniania parowników? Przedmiotem oceny jest proces odszraniania przy pomocy gorącego gazu (gorących par czynnika) w warunkach komory mroźniczej z parownikiem podsufitowym. W części pierwszej artykułu („TCHiK”, nr 1-2/2018) Autor rozważał efektywność tego procesu realizowanego za pomocą gorącej pary czynnika chłodniczego. W części drugiej tematyka ta jest kontynuowana w kierunku m. innymi optymalizacji użytecznej wydajności chłodnicy powietrza i dodatkowo odniesiona do zagadnień niezawodnej i bezpiecznej eksploatacji.
EN
The paper deals with the question of hot gas defrosting optimization in a low temperature system equipped with under-ceiling air cooler. This is the continuation of the first part („TCHiK” no 1-2/2018) with a special regard to useful capacity of the air cooler, reliability and safety of operation.
EN
Helicopters, in comparison to other aircrafts, have much lower flight speeds and manoeuvrability, which makes them easy targets for actual combat assets like ground to air or air-to-air infrared-guided missiles. Current techniques aim to increase the combat effectiveness and lifetime of military helicopters performing combat missions by reducing the possibility of their detection on battlefield, thereby increasing their flight time without fire attack and reduce effects of potential strike. When designing new helicopter types, especially for combat applications, it is essential to pay enormous attention to infrared emissions of the solid parts composing the helicopter’s structure, as well as to exhaust gases egressing from the engine’s exhaust system. Due to their high temperature, exhaust gases, egressed to the surrounding are a major factor in infrared radiation emission level and, in consequence, detectability of a helicopter performing air combat operations. This article presents the possibility to decrease the infrared radiation level that is emitted to the environment by helicopter in flight, by cooling hot exhaust in special ejective cooler. Article presents also the exhaust cooler operation principles and results of numeric analysis of concept exhaust cooler adapted to cooperate with PA-10W turbine engine. Numeric analysis presented promising results in decreasing the infrared emission level by PA W-3 helicopter in flight, as well as increasing its stealth properties.
8
Content available remote AMET SC – nowa aplikacja internetowa dla klientów oraz nowości w ofercie
PL
W ostatnim czasie firma AMET ponownie rozszerzyła swój asortyment elementów hydrauliki siłowej. Zwracając uwagę na dość istotną kwestię, jaką jest utrzymanie prawidłowej temperatury oleju w układzie, wprowadziliśmy do oferty wymienniki ciepła. Obecnie w układach hydrauliki siłowej stosowane są przede wszystkim dwa rodzaje chłodnic – powietrzno-olejowe oraz wodno-olejowe.
RU
Температура наддувочного воздуха на входе в дизель оказывает значительное влияние на его технико-экономические показатели. Значения оптимальной температуры наддувочного воздуха увеличиваются при снижении мощности. Для подогрева наддувочного воздуха в разработанной системе используется теплота, выделяемая дизелем в его систему охлаждения при работе ДВС на частичных нагрузках и при низких температурах наружного воздуха. Система содержит водяные и полупроводниковые термоэлектрические охладители и подогреватели наддувочного воздуха, трехходовые перепускные устройства и вентилятор с электроприводом переменного тока, для управления которым применен микропроцессорный контроллер. Приводится схема и описание принципа действия системы.
EN
The temperature of the charge air inlet, diesel has a significant impact on its economic performance. Values of the optimal temperature of inlet air increases at lower power. To heat the charge air in the developed system uses the heat released by the engine in its cooling system during operation of internal combustion engine at partial loads and at low temperatures. The system contains water and semiconductor thermoelectric coolers and warmers charge air three-way bypass device and fan AC drive to control which is applied to a microprocessor controller. Provides a diagram and description of the operating principle of the system.
PL
Metoda obliczeniowa pozwala na analizę wariantową przebudowy instalacji w celu poprawy rozpływu wody chłodzącej do poszczególnych chłodnic popiołu. Wyniki proponowanych modernizacji, w połączeniu z analizą nakładów inwestycyjnych ich wprowadzenia, mogą ułatwić inwestorowi podjęcie decyzji o zakresie i kosztach przyszłych prac remontowych.
EN
The paper presents a method of modeling of the cooling water propagation in a series-parallel system to a boiler auxiliary equipment. The results of calculations are presented in the form of characteristics that illustrate the impact of introduced modifications to the total flow rate of the water circulating in the modeled system. The presented methodology allows analysis of possible reconstruction variants of the installation in order to improve the propagation of the cooling water to individual auxiliary equipment. The results of the proposed modernization in conjunction with the analysis of investment outlays will allow an investor to decide on the scope and cost of future renovations.
PL
Dla właściwego działania każdego urządzenia wentylacyjnego lub klimatyzacyjnego konieczny jest prawidłowy dobór nagrzewnicy i chłodnicy powietrza. Obliczenie mocy tych wymienników ciepła odbywa się zawsze w oparciu o dane klimatyczne. W artykule zwrócono uwagę na problemy związane z takim doborem wymienników ciepła, ze szczególnym uwzględnieniem chłodnicy.
EN
The correct choice of the air heater and the air cooler is necessary for correct operation of ventilation and air conditioning devices. Power calculation for those heat exchangers is always based on the climatic data. In this paper has been called the attention to difficulties of correct choice of heat exchangers, specifically the air cooler.
12
Content available remote Analiza systemu klimatyzacji dwuprzewodowej z wykorzystaniem pompy ciepła
PL
Celem publikacji jest analiza systemu klimatyzacji dwuprzewodowej z wykorzystaniem pompy ciepła współpracującej z chłodnicą centrali klimatyzacyjnej i nagrzewnicą przewodową. Przedstawiono przykład projektowania systemu klimatyzacji dwuprzewodowej z wykorzystaniem pompy ciepła oraz dokonano obliczeń niezbędnych w doborze urządzeń pracujących w systemie. Sporządzono obliczenia klimatyzacji dwuprzewodowej dla założonych w projekcie parametrów, dzięki czemu możliwe było określenie mocy chłodniczej i grzewczej potrzebnej do klimatyzacji pomieszczeń w celu zapewnienia komfortu cieplnego. Dla obliczonej mocy chłodniczej dokonano doboru pompy ciepła firmy VATRA, zapewniając źródło chłodu dla chłodnicy centrali klimatyzacyjnej oraz źródło ciepła dla nagrzewnicy powietrza. Ciepło, które powstało podczas eksploatacji pompy ciepła, jest alternatywnym źródłem energii zapewniającym odpowiednie parametry w pomieszczeniach. Zamieszczony w pracy schemat ilustruje powiązanie systemu klimatyzacji dwuprzewodowej współpracującej z pompą ciepła, gdzie pompa ciepła jest głównym źródłem zasilania chłodnicy w chłód, a nagrzewnica powietrza w ciepło. Parametry powietrza w pomieszczeniach przedstawiono w formie graficznej w postaci wykresu i-x Moliera. Opisano możliwości zagospodarowania nadwyżek ciepła, które powstały podczas eksploatacji pompy ciepła.
EN
The publication presents the example of designing the two-wire air-conditioning system with the use of heat pump. What is more, there are calculations presented, which are indispensable when it comes to the selection of devices working in the system. Two-wire air- conditioning calculations have been made for the parameters established in the project. Thanks to that fact, it was possible to determine cooling and heating power needed for the air-conditioning of the accomodations in order to provide thermal comfort. For the calculated cooling power, VATRA heat pump has been selected. It provides the source of coolness for the cooler of air-handling unit and on the other hand the source of heat for the air-heater. Heat, which was generated during the operating of the heat pump is an alternative source of energy, which guarantees suitable parameters in accommodations. The scheme enclosed in the work, illustrates the connection between two-wire airconditioning system using heat pump, where the pump is the main source of coolness for the cooler and the air -heater which is the main source of heat. The air parameters in rooms were shown in graphic form by means of i-x Molier's diagram. Additionally there were several proposals presented on how to manage the heat excesses, which occured during the operating of the heat pump.
13
Content available remote Extreme intercooling of charging air and gaseous emissions
EN
Recently we have theoretically dealt with some questions related to the formation of harmful gaseous emissions namely through a design of a mathematical model of flow and burning in an engine combustion space. We also paid attention to solutions enabling the reduction in quantity of harmful gaseous emissions and their verification through calculations, by means of mathematical modelling taking into account the mentioned solutions. Preparation of the CAD data was done in CATIA V5 software, the mesh preparation in the preprocessor Gambit and the calculation itself as well as visualisation of results were done in the Fluent. One of the suggested solutions was to use the cold produced by a non-conventional “cooling combustion engine” for extreme intercooling of the charge medium. In this paper we present results of the experiments carried out on a diesel combustion engine. The extreme reduction in the temperature of the charge air was done through two-stage intercooling.
PL
Ostatnio zajmowaliśmy się teoretycznie niektórymi problemami związanymi z powstawaniem szkodliwych emisji gazowych, mianowicie przez opracowanie modelu matematycznego przepływu i spalania w przestrzeni spalania silnikowego. Zwróciliśmy też uwagę na rozwiązania umożliwiające ilościową redukcję szkodliwych emisji gazowych i ich weryfikację przez obliczenia za pomocą modelowania matematycznego z uwzględnieniem wzmiankowanych rozwiązań. Przygotowanie danych CAD zostało wykonane z użyciem programu CATIA V5, przygotowanie siatki w preprocesorze Gambit, a same obliczenia i wizualizację wyników wykonano w programie Fluent. Jedno z proponowanych rozwiązań polegało na zastosowaniu zimna wytwarzanego przez niekonwencjonalny „silnik z chłodzeniem spalania” dla ekstremalnego chłodzenia międzystopniowego ładunku. W niniejszym artykule przedstawiamy wyniki badań doświadczalnych przeprowadzonych na wysokoprężnym silniku spalinowym. Maksymalna redukcja temperatury powietrza ładunku została dokonana przez chłodzenie dwustopniowe.
14
Content available remote Układ chłodzenia wielozadaniowej platformy gąsienicowej
PL
W artykule przedstawiono nowe rozwiązanie układu chłodzenia napędu podwozia pojazdu gąsienicowego. Opisano genezę tematu, najważniejsze elementy projektu i wyniki badań. Omówione rozwiązanie zostało zaprojektowane w OBRUM sp. z o.o.
EN
In this paper the new solution of the cooling system applied into multifunctional combat platform has been presented. Genesis of the system, calculations, design and test results has been described.
PL
W artykule przedstawiono wyniki badań wpływu temperatury cieczy chłodzącej na wybrane parametry regulacyjne pracy silnika. Badania zostały przeprowadzone na pojeździe marki Opel Zafira B napędzanym silnikiem Zł o pojemności skokowej 2200 [cm3] z systemem bezpośredniego wtrysku benzyny do komory spalania.
EN
The results of investigations of coolant temperature influence on selected regulation parameters are presented in this paper. The research was conducted on Opel Zafira B with 2200 [ccm] direct gasoline injection engine.
PL
W pracy opisano uszkodzenie dwustopniowej chłodnicy przeznaczonej do chłodzenia sprężonej mieszanki palnej w układzie dolotowym doładowanego silnika gazowego z zapłonem iskrowym.
EN
The paper describes damage of the two-stage cooler designed for cooling of the compressed air-fuel mixture in the inlet system of the biogas supercharged spark ignition engine.
PL
Artykuł dotyczy analizy cieplno-przepływowej procesu chłodzenia wodorem generatora bloku nr 6 w Elektrowni Jaworzno III. Analiza oparta jest na podstawie dostarczonych danych z ciągłego monitoringu pracy nowych, zmodernizowanych chłodnic wodorowych, wykonanych z rur żebrowanych. W układzie chłodzenia rolę czynnika odbierającego ciepło spełnia woda rzeczna, która w czasie eksploatacji generuje osady w przekrojach wewnętrznych rur. Powoduje to z czasem spadek efektywności chłodzenia i prowadzi do wzrostu temperatury wodoru ponad wartość krytyczną. W artykule na podstawie obliczeń symulacyjnych, bazujących na rzeczywistych danych, przeprowadzono analizę wpływu narastania osadów na wydajność cieplną chłodnicy wodoru.
EN
The paper refers to thermal-flow analysis of the process of cooling an electric power generator with hydrogen in unit No 6 at the Jaworzno III Power Plant. This analysis is based on the data acquired from continuous monitoring of operation of new, modernised hydrogen coolers made from finned tubes. The role of heat collecting medium in a cooling system plays a river water, which causes that deposits appear on the cross-sections of the tubes. This results sometimes in the decrease of cooling efficiency leading to the temperature increase over the critical level. The simulation calculations based on real data were made in order to analyse an effect of accumulation of deposits on the caloric effect of the hydrogen cooler.
PL
Na podstawie przepisów PN-EN 1672-2:1999 będącej odpowiednikiem Normy Europejskiej EN 1672-2 omówiono wymagania higieniczne dotyczące konstrukcji aparatów fluidalnych, ze szczególnym uwzględnieniem rodziny fluidalnych suszarek i chłodziarek cukru przedstawionych poprzednio w pracach Heima i Tomalczyka [1998, 2000, 2002].
EN
Sanitary requirements for fluid-bed equipment, with special reference to fluid-bed dryers and coolers of sugar peresented by Heim and Tomalczyk in their previous works [1998, 2000, 2002] were discussed with reference to regulations quoted in Polish standard PN-EN 1672-2:1999 that is an equivalent of the European standard EN 1672-2.
PL
Przedłożono nową koncepcję wytwarzania rur obustronnie żebrowanych. Połączenie technologii wyciskania i skręcania kołowego profilu ożebrowanego wewnętrznie z nawalcowaniem radiatora zewnętrznego, z silnym dociskiem w strefie złącza bimetalowego, zapewnia uzyskanie produktu o wyjątkowych własnościach użytkowych. Własności te dokumentują porównawcze badania cieplne chłodnic wykonane z rur żebrowanych wewnętrznie gładkich i obustronnie żebrowanych z wymuszeniem wirowego przepływu medium wewnątrz rury.
EN
We present the new concept of both side finned tubes production process. The combined use of extrusion forging and circular torsion of the tube with inside fins with the production of outside fins in cold rolling process, where strong bimetallic junction is being formed, allows obtaining the product with exceptional functional quality. These properties are illustrated by the results of comparative thermal measurements of coolers manufactured from outside finned tubes (with bare tube inside) or from both side finned tubes, where the whirl flow of fluid inside the tube is generated.
20
Content available remote Warunki schładzania mleka
PL
Celem badań było sprawdzenie poprawności schładzania mleka przy zastosowaniu schładzalników zbiornikowych różnych wielkości wykorzystywanych przy gromadzeniu mleka co najmniej z dwóch dojów. Wykazano, że tylko jeden w konkretnych warunkach na przebadane cztery spełniał zalecenia co do czasu chłodzenia i temperatury mleka. Zakres corocznych przeglądów urządzeń do pozyskiwania mleka należy rozszerzyć o sprawdzenie poprawności działania schładzalnika.
EN
The research objective was to evaluate the milk cooling correctness when using tank coolers of various sizes used at collecting milk from at least two milkings. It was proved that in specific conditions only one in tested four satisfied the recommendations as to the cooling time and milk temperature. The range of annual inspections of the milk collection equipment should be extended by the cooler operating correctness testing.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.