The paper presents the design of a two-stage subcritical compressor heat pump operating in an air-to-water system and running on environmentally friendly refrigerants. The pump is dedicated to buildings where there is a high-temperature central heating system and wall-mounted radiators are used as heat receivers. The first stage of the unit was supplied with R290 refrigerant and the second stage with R1234 ze(E) refrigerant. The nominal heating power of the unit is 10kW for a lower source temperature in the range -20°C÷10°C. The unit's refrigeration system was designed and simulation tests were carried out to determine the unit's operating parameters for the lower source temperature in the range -20°C÷10°C, the condensation temperature of the stage I refrigerant for values: 20°C, 25°C, 30°C and the condensation temperature of the stage II refrigerant in the range 30°C÷60°C. The value of the coefficient of performance (COP) was determined in relation to the heating power generated in stages I and II to the electricity consumed, which value, depending on the operating parameters, ranges from 2.55 to 5.6. The value of the COP related to the heating power received from the stage II condenser to the total power consumed by the stage I and II compressor, depending on the operating parameters, ranges from 1.5 to 2.9. It was found that by using a stepless adjustment of the volumetric efficiency of the stage I and II compressor, it is possible to match the heating power of stage I to the cooling power of stage II and thus increase the COP value by 50%.
EN
In order to further increase the energy efficiency of the experimental building, field experiments were conducted to maintain the proper thermal regime of its premises when using a heat pump heating system. The paper presents the results of experimental studies of the operating parameters of the heat pump heat supply system of an energy-efficient building of the Institute of Engineering Thermophysics of the National Academy of Sciences of Ukraine. The given analysis of the energy efficiency of the operation of the "soil-water" type heat pump in the nominal mode with the maximum load showed a high value of the energy conversion coefficient.
PL
Artykuł przedstawia wyniki pomiarów temperatury na wybranych głębokościach wzdłuż pionowych gruntowych wymienników ciepła przy różnej wydajności dolnego źródła w przypadku systemu grzewczego z wykorzystaniem sprężarkowej pompy ciepła. W eksperymencie analizowano wybrane przypadki pracy systemu grzewczego z pompą ciepła - z jednym, dwoma oraz trzema pionowymi gruntowymi wymiennikami, stanowiącymi dolne źródło ciepła. Celem pracy było badanie zachowania się gruntu w przypadku niedoszacowania, dopasowania oraz przewymiarowania dolnego źródła ciepła.
EN
The article presents the results of temperature measurements at selected depths along vertical ground heat exchangers with different efficiency of the lower heat source for a heating system based on a compressor heat pump. The experiment analyzed selected cases of operation of a heating system with a heat pump - with one, two and three vertical ground heat exchangers. The aim of the study was to investigate the behavior of the soil in the event of underestimation, adjustment and oversizing of the lower heat source.
EN
The description of original technical decision of using heat pump for heating part of administrating building is described. The hydraulic connection scheme has been developed and selection of heat devices was made for it. The energy efficiency for using heat pump in heating season is analyzed. Based on the obtained experimental data, the coefficient of performance of the heat pump was calculated for the above mode of operation of the heat supply system. With such indicators, a significant saving of thermal energy is achieved in comparison with the use of a centralized heat supply system.
EN
The basic metrological problem analyzed in this article is the experimental determination of the COP coefficient for arefrigerating system working in a stationary cooling chamber. This issue is because manufacturers of chillers provide the value of this coefficient in device technicaldata.In practice, after installing the refrigeration unit, the COP is often lower. The paper presents amethod of balancing cooling energy for a complete refrigeration system.
PL
Podstawowym problemem metrologicznym, który autorzy pragną przedstawić jest eksperymentalne wyznaczenie współczynnika COP dla układu chłodniczego, pracującego w stacjonarnej komorze chłodniczej. Zagadnienie to jest istotne, ponieważ producenci agregatów chłodniczych najczęściej podają współczynnik COP dla agregatu chłodniczego. W praktyce po zamontowaniu agregatu chłodniczego w komorze chłodniczej współczynnik COP jest niejednokrotnie niższy. Trudność z wyznaczeniem współczynnika COP w układzie chłodniczym polega na koniczności zbilansowania mocy chłodniczej dla całego układu wraz z komorą chłodniczą. W pracy przedstawiono sposób bilansowania energii chłodniczej dla kompletnego układu chłodniczego oraz opisano budowę stanowiska do wyznaczania współczynnika COP.
PL
W artykule rozpatrywano wpływ poziomu modulacji mocy gruntowej pompy ciepła na wartość współczynnika wydajności. Badania eksperymentalne wykonano w Instytucie Inżynierii Mechanicznej SGGW wykorzystując stanowisko z urządzeniem wyposażonym w inwerterowy napęd sprężarki. Układ hydrauliczny i oprogramowanie sterowników pozwala na automatyczne osiąganie stanu ustalonego dla zadawanych wartości temperatury źródła i odbiornika oraz wymuszonego poziomu mocy grzewczej sprężarki. W większości prób temperaturę źródła ustalono na poziomie 6°C, a temperaturę odbiornika na wlocie do skraplacza w zakresie wartości od 23°C do 47°C. Zarówno w serii prób odpowiadających regulacji mocy ilościowej, jak też regulacji jakościowej najwyższy współczynnik wydajności pompa ciepła osiągała przy pracy z mocą odpowiadającą 60-70% mocy maksymalnej dla danej kombinacji temperatury źródła i odbiornika. Przy wysterowaniu mocy poniżej 40% i powyżej 80% współczynnik wydajności pompy ciepła obniża się do 20% w skali względnej.
EN
The paper analyses the influence of the level of ground power modulation of the heat pump on the value of the COP coefficient. The experimental research was carried out in the Institute of Mechanical Engineering SGGW using a stand with a device equipped with an inverter drive of the compressor. Hydraulic installation and software of the controllers allows for automatic achievement of the state set for the set source and receiver temperatures and the forced heating capacity of the compressor. In most tests, the source temperature was set at 6°C and the condenser inlet water temperature at 23°C to 47°C. Both in a series of tests corresponding to the quantitative capacity control, as well as in the quality capacity control, the highest coefficient of performance was achieved by the heat pump in operation with a capacity corresponding to 60-70% of maximum capacity for a given combination of source and load temperatures. If the capacity of the heat pump is controlled below 40% and above 80%, the COP coefficient of the heat pump is reduced to 20% on a relative scale.
PL
W artykule porównano wartości sezonowego współczynnika efektywności grzewczej wybranych pomp ciepła, określone na podstawie normy PN-EN 14825, wytycznych VDI 4650 oraz danych szacunkowych zawartych w rozporządzeniu w sprawie metodologii wyznaczania charakterystyki energetycznej budynku. W ramach przeprowadzonej analizy wskazano na różnice w uzyskanych wynikach oraz przyczyny ich występowania. Wykorzystane metody różnią się od siebie zarówno sposobem, jak i zakresem uwzględnienia poszczególnych czynników mających wpływ na wartość sCOP. Pomimo że żadna z porównywanych metod nie uwzględnia wszystkich czynników związanych z eksploatacją pomp ciepła, podkreślono, że pozwalają one na istotną poprawę jakości analiz energetycznych w stosunku do wykorzystania danych szacunkowych.
EN
The paper presents comparison of values of seasonal coefficient of performance of selected heat pumps, determined on the basis of PN-EN 14825, VDI 4650 guidelines and estimated data provided in the regulation on the methodology for determining the energy performance of a building. In the analysis, the differences in the obtained results an well as the causes for their occurrence were indicated. The methods used differ in both the way and scope of taking into account various factors affecting the sCOP value. Although none of the compared methods takes into account all of the factors related to the operation of heat pumps, it was emphasized that they allow a significant improvement in the quality of energy analyses compared to the use of estimated data.
EN
The operation processes of adsorptive solar refrigerators based on composite adsorbents ‘silica gel - sodium sulphate’ were studied. The correlation between the adsorbent composition and the coefficient of the energy performance of the device was stated. As a consequence of the decreasing of adsorbent mass, the coefficient of performance is increased when sodium sulphate content in the composite increased. Effect of the regeneration process parameters on the composite on the coefficient of performance of the adsorptive refrigenerator was stated. The growth of the coefficient of performance is shown to result from decreasing the difference between adsorbent temperature and regeneration temperature from 85 to 55°C. The maximum values of the coefficient of performance of studied solar adsorptive refrigenerator about of 1.14 are stated for composites containing about 20 wt. % silica gel and 80 wt. % sodium sulphate.
EN
The subject of the research was an air-water heat pump, model PCUW 2.5kW from HEWALEX, installed in a single-family house. The pump is only used for heating water. The research was carried out from 25-08-2017 to 18-09-2017 in the village of Zborowice, in Malopolska region, Poland. The data were recorded from the heat pump system: temperature of the lower heat source (external air), temperature of the upper heat source (water temperature in the tank), time of heat pump was calculated during the analysed cycle of work and electrical energy consumption. The Coefficient Of Performance (COP) of the analysed air-water heat pump was determined. The analysis of the results was carried out using the MATLAB and EXCEL statistical tools. The correlation between COP coefficient and external air temperature is strong: 0.67.
10
Content available Powietrzne pompy ciepła w audytach energetycznych
PL
Pompy ciepła, ze względu na wysoki współczynnik efektywności działania (COP, ang. coefficient of performance), często wybierane są jako wariant przedsięwzięcia mającego na celu poprawę efektywności energetycznej w budynku. W niniejszym artykule przedstawiony został jeden z obecnie najbardziej efektywnych sposobów wytwarzania ciepłej wody użytkowej i ogrzewania budynków, jakim jest zastosowanie powietrznej pompy ciepła. Zaprezentowano zasadę działania takiego urządzenia w instalacji oraz główne parametry wpływające na ich efektywność. Ponadto omówiono zasadność stosowania pomp ciepła, w ujęciu wyboru ich jako wariant przedsięwzięcia termomodernizacyjnego. Omówione zostały zagadnienia związane z prawidłowym doborem urządzenia na etapie obliczeń audytorskich. W końcowej części pracy, autorzy przedstawili przykład obliczeniowy doboru powietrznej pompy ciepła w audycie energetycznym, wraz z określeniem efektu ekologicznego zastosowania tego przedsięwzięcia.
EN
Paper presents one of the most efficient ways of producing hot water and heating of buildings is the present one, which is the use of an air heat pump. They are often chosen to improve energy efficiency in a building. The principle of operation and main parameters influencing their effectiveness were presented. In addition, the use of heat pumps has been discussed in terms of their choice as a variant in energetic audit. The problems related to the correct device selection at the stage of the audit calculations were discussed. In the final part of the paper, the authors presented a computational example of the air-to-water heat pump selection in the energy audit. Moreover the ecological analysis related to different source of energy in building was presented.
11
Content available Efektywność pompy ciepła a zużycie CWU
PL
Omówiono jeden z obecnie najbardziej efektywnych sposobów wytwarzania ciepłej wody użytkowej (CWU), jakim jest zastosowanie powietrznej pompy ciepła ze zintegrowanym zasobnikiem wodnym. Przedstawiono zasadę działania takiego urządzenia w instalacji przygotowującej ciepłą wodę. Opisano także stanowisko badawcze ze wskazaniem wielkości mierzonych. W części analitycznej artykułu zawarto wybrane wyniki przeprowadzonych pomiarów, których celem było wyznaczenie wskaźników efektywności energetycznej i ekonomicznej zastosowania omawianego rozwiązania. Uzyskane wartości odniesiono do trzech cykli poboru wody, zbliżonych do cykli zalecanych w PN-EN 16147 do badań takich urządzeń.
EN
This paper discusses one of the most effective ways of producing domestic hot water (DHW) based on air-source heat pump with an integrated tank. The principle of operating such equipment is also presented in a hot water installation. Moreover, the experimental set-up is described and values of measurements and reported. In the experimental part, measurements were conducted with the aim of determining the parameters representing the energy and economic efficiency of the proposed solution. The obtained values were compared to the values gained during three tapping cycles which were similar to the recommended reference in EN 16147.
EN
In this study a cooling ejector cycle coupled to a compression heat pump is analyzed for simultaneous cooling and heating applications. In this work, the influence of the thermodynamic parameters and fluid nature on the performances of the hybrid system is studied. The results obtained show that this system presents interesting performances. The comparison of the system performances with hydrofluorocarbons (HFC) and natural fluids is made. The theoretical results show that the a low temperature refrigerant R32 gives the best performance.
PL
Badano zastosowanie pompy ciepła typu powietrze/woda do ogrzewania wody w zasobniku o pojemności 160 l i jednoczesnego chłodzenia powietrza wewnątrz pomieszczenia laboratoryjnego Wydziału Inżynierii i Technologii Chemicznej Politechniki Krakowskiej. Omówiono wpływ takich parametrów jak temperatura powietrza, temperatura wody w zasobniku, przerwy w pracy pompy ciepła oraz częstotliwość pracy sprężarki na uzyskiwany współczynnik efektywność pracy pompy ciepła (COP). Średnia wartość współczynniki! COP w seriach pomiarowych zawierała się w przedziale od 2,1 do 2,7.
EN
The paper presents the usage of air-to-water heat pump for heating domestic hot water (DHW) in a 160 l storage tank and simultaneous cooling of air inside a laboratory room of the Department of Chemical Engineering and Technology of the Cracow University o f Technology. An influence of such parameters as air temperature, storage tank temperature, heat pump interruptions and compressor operating frequency on the achieved coefficient of performance (COP) of the heat pump is discussed. The average values of COP in the measurement series ranged from 2.1 to 2.7.
PL
Użytkownicy budynków mieszkalnych coraz częściej decydują się na wybór pompy ciepła jako źródła ciepła do ogrzewania. Dużą popularnością cieszą się sprężarkowe pompy ciepła powietrze/woda. W procedurze doboru tego typu pompy bardzo ważne jest założenie odpowiedniej temperatury odpowiadającej tzw. punktowi biwalencji, czyli temperatury poniżej której pompa będzie zastępowana lub wspomagana przez inne lub dodatkowe źródło ciepła. Temperatura punktu biwalencji powinna zostać dobrana tak, aby pompa ciepła uzyskiwała jak najwyższą efektywność w ciągu całego sezonu grzewczego. W artykule przeanalizowano zmienność sezonowego współczynnika efektywności energetycznej SCOP powietrznych pomp ciepła w 59 lokalizacjach budynku referencyjnego w Polsce. Na tej podstawie wskazano optymalną temperaturę punktu biwalencji każdej lokalizacji. Na podstawie przeprowadzonej analizy zaproponowano średnie wartości temperatury punktów biwalencji w strefach klimatycznych podanych w normie PN-EN 12831, które mogą być stosowane do uproszczonego doboru pompy ciepła typu powietrze/woda.
EN
More and more owners of houses consider installing heat pumps as the main source of heating. The most popular available types of heat pumps are air-source compressor heat pumps. While selecting this type of heat pump, establishing the temperature of a bivalent point is very important. Below this value of temperature, a selected heat pump has to be supported by another source of heating. The temperature of the bivalent point should allow to reach the highest heat pump performance over the whole heat season. The analysis of a changing SCOP coefficient values for air-source heat pumps for 59 localisations of the reference building in Poland was conducted in the article. On the basis of the results, the optimal temperature of bivalent point for each localisations was indicated. The average values of temperature of the bivalent point for climate zones specified in PN-EN 12831 Standard were also proposed. These values could be used for simplified selection of air-source heat pumps.
EN
The dynamic performance of cylindrical double-tube adsorption heat pump is numerically analysed using a non-equilibrium model, which takes into account both heat and mass transfer processes. The model includes conservation equations for: heat transfer in heating/cooling fluids, heat transfer in the metal tube, and heat and mass transfer in the adsorbent. The mathematical model is numerically solved using the method of lines. Numerical simulations are performed for the system water-zeolite 13X, chosen as the working pair. The effect of the evaporator and condenser temperatures on the adsorption and desorption kinetics is examined. The results of the numerical investigation show that both of these parameters have a significant effect on the adsorption heat pump performance. Based on computer simulation results, the values of the coefficients of performance for heating and cooling are calculated. The results show that adsorption heat pumps have relatively low efficiency compared to other heat pumps. The value of the coefficient of performance for heating is higher than for cooling
EN
Heat utilization for cooling capacity production is nowadays a desirable challenge in several industrial applications. There are lots of industrial processes with low parameters of heat generated as by-product, which utilization is very important to improve theirs total energy efficiency. Waste heat driven chillers seem to be great competitors for mechanical chillers. Among them special attention should be paid to adsorption chillers, since they can be powered with low – temperature heat sources. The paper presents a model of a single-stage adsorption chiller with silica gel as adsorbent and water, acting as a refrigerant. The performed model allows to predict the behaviour of the adsorption chiller, among others the main energy efficiency factors, such as coefficient of performance (COP) and cooling capacity (CC) for different working conditions.
PL
Artykuł jest kontynuacją tematyki przedstawionej w części pierwszej (nr 9-2015) oraz części drugiej (nr 10-2015). Autorzy nawiązują do konsekwencji, jakie niosą ze sobą ograniczenia stosowania syntetycznych czynników chłodniczych z grupy CFC i HCFC. W artykule przedstawiono analizę wpływu rodzaju czynnika chłodniczego na efektywność sprężarkowego układu chłodzenia przeznaczonego do współpracy z komorą chłodniczą do przechowywania produktów żywnościowych. W analizie tej wzięto pod uwagę zmienność efektywności urządzenia w zależności od zmiany parametrów pracy oraz płynu roboczego. Ze względu na restrykcje związane z prawodawstwem unijnym (o czym mowa była w poprzednich częściach artykułu), w rozważaniach ujęto takie substancje, jak czynniki naturalne R600a, R290 oraz te należące do grupy HFC (R134a, R365mfc), a także czynniki syntetyczne z grupy HFO (R1234yf, R1234ze). Omówiono więc płyny, które znajdują szerokie zastosowanie w nowoczesnych konstrukcjach urządzeń chłodniczych.
EN
The article presents the continuation of issues which have been shown into the first and second parts of work. The authors refer to the consequences of restrictions connected with the use of CFC and HCFC refrigerants. The present paper has been concentrated on the relation between a kind of working fluid and efficiency of refrigerator compartment. Mathematical analysis which has been shown into article included changing of working parameters and different kinds of working fluids. Due to the EU law restrictions, the authors considered only the most perspective refrigerants: those from natural group R290 and R600a, from HFC group R134a and R365 mfc, and from new HFO group R1234yf, R1234ze.
18
PL
W pracy przedstawiono charakterystykę powietrznych pomp ciepła z zintegrowanym zasobnikiem wodnym do produkcji ciepłej wody użytkowej. Przedstawiono zasadę działania powietrznych pomp ciepła. Omówione zostały podstawowe elementy konstrukcyjne takie jak: sprężarki, skraplacze, parowacze oraz zawory regulacyjne. Przytoczono sprawności 28 urządzeń dostępnych na rynku europejskim, których współczynnik COP kształtował się w zakresie od 2,3 do 3,8. Średnia wartość COP wyniosła 3,1.
EN
In this paper the characteristic of air-water heat pump with integrated tank for hot water purpose was described. The principle of operation of air source heat pump was presented. Furthemore, the basic construction elements such as: compressors, condensers, evaporators and the control valves was characterized. The principle operation of mentioned above elements used in air source heat pump with integrated tank was described. The paper presents the current norm EN 16147 for calculating the coefficient of performance of heat pumps for domestic hot water production. Moreover the efficiency of 28 devices available on the European market was presented. Whereas the coefficient of performance were in range from 2.3 to 3.8. The averaged value COP of the heat pumps were 3.1.
PL
Tematyka artykułu dotyczy efektywności energetycznej pomp ciepła typu powietrze/woda. Przedstawiono systematykę pomp ciepła oraz możliwe tryby ich pracy w układach ogrzewania i przygotowania ciepłej wody użytkowej. Przeprowadzono analizę zmienności współczynnika COP trzech pomp ciepła typu powietrze/woda w okresie rocznym. Analiza wykonana została na przykładzie budynku referencyjnego. Dokonano oceny przydatności współczynnika COP do opisu efektywności pomp ciepła. Porównano sezonowy współczynnik efektywności energetycznej SCOP analizowanych pomp ciepła.
EN
The article concerns the energy efficiency of air-source (or air to water) heat pumps. Types of heat pumps and their possible operative modes in heating and usable hot water preparation systems are presented. The aim of the article is to analyse the impact of the COP coefficient variability of a heat pump during the annual consumption of energy. The analysis was carried out taking into consideration seasonal variations of heat demand for the reference building in Kraków. The usefulness of the coefficient for characterizing the pump performance has been evaluated. The results are related to the value of SCOP for three heat pumps of different manufacturers.
PL
W artykule zaprezentowano analizę technicznych możliwości wykorzystania ciepła dostarczanego w okresie letnim przez miejską sieć ciepłowniczą do napędu sorpcyjnych agregatów ziębniczych. Analizę uzupełniono obliczeniami wskaźników ekonomicznych i ekologicznych przypadku zastosowania takiego urządzenia do chłodzenia budynku biurowego w realiach krakowskiej sieci ciepłowniczej. W obliczeniach wykorzystano charakterystyki produktów dostępnych na rynku oraz uwzględniono różne warianty sterowania wydajnością odpowiednio do aktualnego obciążenia chłodniczego obliczanego dla interwałów godzinowych za pomocą autorskiego modelu obliczeniowego. Proponowany system został porównany z tradycyjnym rozwiązaniem chłodzenia za pomocą agregatu sprężarkowego ze skraplaczem chłodzonym powietrzem w zakresie zapotrzebowania na energię końcową i pierwotną, emisji CO2 oraz bezpośrednich kosztów eksploatacyjnych przy spełnieniu tych samych wymagań ilościowych i jakościowych przez obydwa systemy.
EN
The article presents an analysis of the technical possibilities of the use of heat supplied in the summer by the municipal district heating network to drive sorption type refrigeration units. The analysis is supplemented with calculations of economic and environmental indicators based on case study of use such a chiller for cooling an office building in the conditions of Krakow’s district heating network. The study was based on real characteristics of the products available on the market, and various options of capacity control have been considered, adequate to the current cooling load computed for hourly intervals, by using an original author's calculation model, presented in the previous papers. The system proposed has been compared with traditional cooling solution using a compressor type water chiller with air-cooled condenser in terms of final and primary energy demands, CO2 emissions and direct operating costs and subject to the same qualitative and quantitative requirements for both systems.