The oral cavity due to its temperature fluctuations, changing pH, high humidity, action of mechanical forces and the presence of microorganisms is a favorable environment for degradation of dental materials. The paper presents comparative results on orthodontic arch-wires AISI304 steel before and after low temperature plasma nitriding carried out at cathodic potential (conventional) and at plasma potential, i.e. in a process incorporating an active screen. Corrosion resistance test on nitrided layers produced on stainless steel were carried out via electrochemical impedance spectroscopy (EIS) and the potentiodynamic method in non-deaerated artificial saliva solution at 37°C. The results were complemented with analysis of the structure, surface topography and microhardness. The results showed an increase in corrosion resistance of AISI304 steel after conventional glow-discharge nitriding.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Opracowano metodę ekstrakcji oraz wyznaczono stabilność krótko- i długoterminową czterech pochodnych (E)-azastilbenu. Pochodne te mogą być stosowane jako związki konserwujące, środki odkażające lub dezynfekujące. Badania przeprowadzono z udziałem ścieków, wody destylowanej i wody powierzchniowej. Proces ekstrakcji opracowano dla czterech kolumn ekstrakcyjnych. Największy odzysk wynoszący blisko 97% uzyskano na dwóch fazach: benzylopropylowej i naftylopropylowej. Średni spadek stabilności testowanych pochodnych po 12 miesiącach, niezależnie od rodzaju matrycy wynosił ok. 30%.
EN
Four substituted stilbazolium halides were studied for stability in aq. mediums (distd. water, surface water, sewage) and recovered by solid-liq. extn. chromatog. on 4 solid phases. The av. decrease in the stability of the tested compds. after 12 months was about 30%. The highest recovering degree (nearly 97%) was achieved on benzylpropyl and naphthylpropyl solid phases.
3
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The phenomenon of corrosion of orthodontic appliances is of interest to both clinicians and researchers dealing with the issue of biocompatibility of medical materials. The oral cavity, due to its temperature fluctuations, changing pH, high humidity, action of mechanical forces and the presence of microorganisms is a favorable environment for degradation of dental materials. This article presents the comparative assessment of the intensity of corrosion of orthodontic archwires made of alloy steel, nickel–titanium and titanium–molybdenum alloys in laboratory conditions. Corrosion resistance examinations were carried out by means of the impedance and the potentiodynamic methods using an Autolab PGSTAT100 potentiostat/galwanostat (Eco Chemie B.V., Holand) with FRA2 module, in non-deaerated artificial saliva solution at 37 °C. An analysis of the impendence method's data showing that the highest corrosion resistance is observed for NiTi arches (3M, USA), while the lowest resistance for SS arches (3M, USA). These observations were confirmed by the data obtained from potentiodynamic tests; it was observed that the average corrosion current density [Icor] was the lowest for nickel–titanium archwires (3M, USA) and averaged 2.50 × 10−3 μA/cm2. The highest Icor corrosion current was observed in the case of steel wires from the same manufacturer and averaged 4.96 × 10−2 μA/cm2.
Degree of conversion (DC) of selected currently used orthodontic adhesive materials, after their polymerization with dental curing light, were investigated in laboratory conditions. Samples of four orthodontic adhesives (Contec LC, Transbond XT, Transbond Plus and Resilience) were prepared in Teflon matrices and then formed into the thickness of 1 mm. After the baseline measurement of crosslinking of the materials with Fourier transform infrared spectroscopy (FT-IR) the samples were cured with treatment light, and then 1 and 24 h after the completion of the photopolymerization process, the values of DC were evaluated. The results were analyzed using the Statistica 8.0 software package. In the process of hypothesis testing the level of significance was assumed at α = 0.05. The statistical analysis yielded significant differences between DC values of orthodontic adhesives tested in both time periods and a significant increase after 24 h storage of the studied orthodontic adhesive systems. It was stated that DC values of the visible light-cured orthodontic adhesives assessed in the present study depend of the type of the composite material. A significant increase in DC occurring with extended period of observation proves that polymerization of dental adhesive materials is a long-term process.
PL
Przeprowadzono w warunkach laboratoryjnych badania stopnia konwersji (DC) wybranych, stosowanych współcześnie ortodontycznych materiałów adhezyjnych po ich polimeryzacji pod wpływem światła widzialnego lampy stomatologicznej. Próbki czterech klejów ortodontycznych (Contec LC, Transbond XT, Transbond Plus i Resilience) przygotowano w teflonowych matrycach, a następnie uformowano do grubości 1 mm. Po wykonaniu za pomocą spektroskopii w podczerwieni z transformacją Fouriera (FT-IR) pomiaru początkowego usieciowania próbek, poddawano je działaniu lampy zabiegowej, a następnie po 1 i 24 h od zakończenia procesu fotopolimeryzacji wyznaczano wartości DC. Uzyskane wyniki analizowano korzystając z pakietu statystycznego Statistica 8.0. W procesie testowania hipotez statystycznych przyjęto poziom istotności α = 0,05. Analiza statystyczna wykazała istotne różnice pomiędzy wartościami DC badanych klejów ortodontycznych wyznaczonymi po upływie 1 i 24 h oraz istotny wzrost DC podczas 24-godzinnego przechowywania ocenianych próbek. Stwierdzono, że wartość DC ocenianych układów adhezyjnych polimeryzowanych światłem widzialnym zależy od rodzaju materiału. Istotny wzrost wartości DC zachodzący wraz z wydłużeniem czasu obserwacji może świadczyć o tym, że polimeryzacja stomatologicznych materiałów adhezyjnych jest procesem długotrwałym.
The study assessed the chemical stability of ConTec LC, Resilence, Light Bond and Transbond XT orthodontic adhesive resins. The subject of the analysis was the release of HEMA (2-hydroxyethylmethacrylate), TEGDMA (triethylene glycol dimethacrylate), EGDMA (ethylene glycol dimethacrylate), UDMA (urethane dimethacrylate) and BPA (bisphenol A) monomers from test sample materials in successive time intervals, using HPLC (high pressure liquid chromatography). The study confirmed the presence of methacrylate monomers and bisphenol A in eluates of the assessed materials regardless of the observation period. The results show that orthodontic adhesive systems polymerized with visible light are chemically unstable, releasing biologically harmful ingredients to the external environment for a long time. Dental materials containing polymer network based on methacrylates require structure modification or elimination of harmful components in order to increase safety of their application.
PL
Oceniano stabilność chemiczną ortodontycznych żywic adhezyjnych ConTec LC, Resilence, Light Bond oraz Transbond XT. Metodą wysokociśnieniowej chromatografii cieczowej (HPLC) analizowano uwalnianie z próbek badanych materiałów monomerów: HEMA (metakrylan 2-hydroksyetylu), TEGDMA (dimetakrylan triglikolu etylenowego), EGDMA (dimetakrylan glikolu etylenowego), UDMA (dimetakrylan uretanu) i BPA (bisfenol A) w kolejnych przedziałach czasowych. Badania potwierdziły obecność monomerów metakrylanowych i bisfenolu A w eluatach ocenianych materiałów, niezależnie od czasu obserwacji. Uzyskane wyniki wskazują, że polimeryzowane światłem widzialnym ortodontyczne systemy adhezyjne są niestabilne chemicznie i w ciągu długiego czasu emitują do środowiska zewnętrznego składniki biologicznie szkodliwe. Materiały stomatologiczne zawierające usieciowane metakrylany wymagają modyfikacji struktury lub eliminacji szkodliwych komponentów w celu zwiększenia bezpieczeństwa ich stosowania.