Elimination of Legionella support factors in plastic pipes

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Eliminacja czynników sprzyjających występowaniu bakterii Legionella w rurach z tworzyw sztucznych
Języki publikacji
EN
Abstrakty
EN
The main aim of this paper is to present the results of the influence comparison of biocides on hot water polypropylene pipes as a part of a longtime investigation on the sustainable and safety of buildings. There are a lot of guidelines that have linked water distribution systems as an infection source and methods on how to eliminate Legionella from water systems. The presence of bacteria in the technical systems of buildings causes contamination, which may be very dangerous if there are good conditions for multiplication. The basic point is the occurrence of biofilms on the walls of distribution pipes as well as material impact. The investigation in the targeted hospital brings together interesting results from a combination of technical solutions and the dosing of biocides and their effect on the inner surface of pipes.
PL
Głównym celem pracy jest przedstawienie wyników badań porównawczych wpływu biocydów na rury polipropylenowe używane do transportu gorącej wody. Badania przeprowadzono podczas długoletniego projektu, który polegał na określeniu zrównoważenia i bezpieczeństwa budynków. Istnieje wiele opracowań, które traktują systemy dystrybucji wody jako źródło infekcji, przedstawiając jednocześnie metody eliminacji Legionelli z systemów wodnych. Obecność bakterii w systemach technicznych budynków powoduje zanieczyszczenie, które może być bardzo niebezpieczne, jeśli występują dobre warunki do namnażania. Główną przyczyną namnażania jest występowanie biofilmów na ścianach rur, a także wpływ materiału. Badania w wybranym szpitalu pozwoliły uzyskać interesujące rezultaty wpływu na wewnętrzną powierzchnię rur przy zastosowaniu połączenia rozwiązań technicznych oraz dozowania biocydów.
Rocznik
Strony
86--91
Opis fizyczny
Bibliogr. 17 poz., rys.
Twórcy
  • Technical University of Kosice, Faculty of Civil Engineering, Institute of Architectural Engineering, Department of Building Services
  • QZP, s.r.o., Hudcova 78 b, Brno, Czech Republic
  • Technical University of Kosice, Faculty of Civil Engineering, Institute of Architectural Engineering, Department of Building Services
Bibliografia
  • [1] Toyosada K., Otani T., Shimizu Y., Managi S., Water quality study on the hot and cold water supply systems at Vietnamese hotels, Water 2017, 9, 251.
  • [2] Bartram J., Chartier Y., Lee J.V., Pond K., Surman-Lee S., Legionella and the prevention of legionellosis, World Health Organization: Geneva, Switzerland, 2007.
  • [3] Whiley H., Legionella risk management and control in potable water systems: Argument for the abolishment of routine testing, Int. J. Environ. Res. Public Health 2017, 14, 12.
  • [4] Whiley H., Keegan A., Fallowfield H., Bentham R., Detection of Legionella, L. pneumophila and Mycobacterium Avium Complex (MAC) along potable water distribution pipelines. Int. J. Environ. Res. Public Health 2014, 11, 7393-7405.
  • [5] Lin Y.E., Stout J.E., Yu V.L., Controlling Legionella in hospital drinking water: an evidence-based review of disinfection methods. Infect Control Hosp Epidemiol. 2011, 32, 166-173, doi:10.1086/657934.
  • [6] Beauté J. et al., Surveillance and outbreak reports. Legionnaires’disease in Europe, 2011-2015, European Centre for Disease Prevention and Control. Legionnaires’ disease in Europe, 2016, ECDC, Stockholm, 2016, First View: 1-12.
  • [7] Kaposztasova D., Vranayova Z., Water Hygiene Audit and Legionella Control in Hospitals. Proceedings 2018, 2, 610.
  • [8] Montagna M.T., De Giglio O., Cristina M.L., Napoli C., Pacifico C., Agodi A., Baldovin T., Casini B., Coniglio M.A., D’Errico M.M., et al., Evaluation of Legionella air contamination in healthcare facilities by different sampling methods: An Italian multicenter study. Int. J. Environ. Res. Public Health 2017, 14.
  • [9] Zuravleff J.J., Yu V.L., Shonnard J.W., Rihs J.D., Best M., Legionella pneumophila contamination of a hospital humidifier: demonstration of aerosol transmission and subsequent subclinical infection in exposed guinea pigs. Am. Rev. Respir. Dis. 1983, 128, 657-61.
  • [10] Copper development center, 2005: Available online: https://www.copper.org/education/cfacts/antimicrobial/ print-category.html (accessed on 2 January 2019).
  • [11] European standard: EN 806 Specifications for installations inside buildings conveying water for human consumption, 2007.
  • [12] Van der Schee W.G., Regulation on legionella prevention in collective water systems, Proceedings of 31st International Symposium CIB W062 Water Supply and Drainage for Buildings, Brussels, Belgium: BBRI., Rotterdam (Netherlands), 2005.
  • [13] Marchesi I., Marchegiano P., Bargellini A., Cencetti S., Frezza G., Miselli M., Borella P., Effectiveness of different methods to control legionella in the water supply: Ten-year experience in an Italian university hospital. J. Hosp. Infect. 2011, 77, 47-51.
  • [14] Ma J.-W., Huang B.-S., Hsu C.-W., Peng C.-W., Cheng M.-L., Kao J.-Y., Way T.-D., Yin H.-C., Wang S.-S., Efficacy and Safety Evaluation of a Chlorine Dioxide Solution. Int. J. Environ. Res. Public Health 2017, 14, 329.
  • [15] Zyara A.M., Torvinen E., Veijalainen A.-M., Heinonen-Tanski H., The Effect of UV and combined chlorine/UV treatment on coliphages in drinking water disinfection. Water 2016, 8, 130.
  • [16] Banach J.L., Sampers I., Van Haute S., van der Fels-Klerx H.I., Effect of disinfectants on preventing the cross- -contamination of pathogens in fresh produce washing water. Int. J. Environ. Res. Public Health 2015, 12, 8658-8677.
  • [17] Lin Y.E., Stout J.E., Yu V.L., Controlling Legionella in hospital drinking water: an evidence-based review of disinfection methods, Infect Control Hosp Epidemiol, 2011, 32, 166-173, doi:10.1086/657934.