Aim of this work is to review and characterize methods and systems that are used to prevent onset and to slow down the progression of the late complications of diabetes. Two groups of methods and systems that might be used to prevent or to slow down the progression of the late complications of diabetes are characterized in this paper. Each of these two groups serves a different purpose. The first group is composed of the systems that facilitate a maintenance of strict metabolic control in diabetic patients, i.e. the systems which are used for monitoring and treatment of diabetes. The second group contains systems that are aimed at screening/monitoring or treatment of the risk factors or the early signs of the late complications. Obesity increases risk of diabetes and its complications. Thus, body mass monitoring and control systems are examples of the tools that belong to this group. Other examples include the diabetic retinopathy telescreening systems and the systems for monitoring of the diabetic foot syndrome.
Twórcy
  • Nałęcz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, ul. Ks. Trojdena 4, 02-109 Warsaw, Poland, pladyzynski@ibib.waw.pl
Bibliografia
  • 1. The World Health Organization: Preventing chronic diseases: a vital investment: WHO global report, 2005.
  • 2. International Diabetes Federation at http://www.idf.org, Last accessed 15.06.2010.
  • 3. The Diabetes Control and Complications Trial Research Group: The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N. Engl. J. Med. 1993, 329, 14, 977-986.
  • 4. UK Prospective Diabetes Study (UKPDS) Group: Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33). Lancet 1998, 352, 9131, 837-853.
  • 5. Ellison J. M., Stegmann J. M., Colner S. L., Michael R. H., Sharma M. K., Ervin K. R., Horwitz D. L.: Rapid changes in postprandial blood glucose produce concentration differences at finger, forearm, and thigh sampling sites. Diabetes Care 2002, 25, 6, 961-964.
  • 6. OrSense: http://www.orsense.com, Last accessed 15.06.2010.
  • 7. Gross T. M., Bode B. W., Einhorn D., Kayne D. M., Reed J. H., White N. H., Mastrototaro J. J.: Performance evaluation of the MiniMed continuous glucose monitoring system during patient home use. Diabetes Technol. Ther. 2000, 2, 1, 49-56.
  • 8. Kovatchev B., Anderson S., Heinemann L., Clarke W.: Comparison of the numerical and clinical occuracy of four continuous glucose monitors. Diabetes Care 2008, 31, 6, 1160-1164.
  • 9. Wentholt I. M., Vollebregt M. A., Hart A. A., Hoekstra J. B., DeVries J. H.: Comparison of a needle-type and a microdialysis continuous glucose monitor in type 1 diabetic patients. Diabetes Care 2005, 28, 12, 2871-2876.
  • 10. Pitzer K. R., Desai S., Dunn T., Edelman S., Jayalakshmi Y., Kennedy J., Tamada J. A., Potts R. O.: Detection of Hypoglycemia With the GlucoWatch Biographer. Diabetes Care 2001, 24, 5, 881-885.
  • 11. Tamada J. A., Garg S., Jovanovic L., Pitzer K. R., Fermi S., Potts R. O., the Cygnus Research Team: Noninvasive glucose monitoring. Comprehensive clinical results. JAMA 1999, 282, 19, 1839-1844.
  • 12. Diabetes Network: http://www.diabetesnet.com/, Last accessed 15.06.2010.
  • 13. Ładyżyński P., Wójcicki J.M., Jóźwicka E., Blachowicz J., Krzymień J.: Reliability of blood glucose self-monitoring and its influence on glycemic control in highly motivated type 1 diabetic patients. Diabetes Care 1999, 22, 5, 854-856.
  • 14. Farmer A., Gibson O. J., Tarassenko L., Neil A.: A systematic review of telemedicine interventions to support blood glucose self-monitoring in diabetes. Diabet. Med. 2005, 22, 10, 1372-1378.
  • 15. Shea S., Weinstock R. S., Starren J., Teresi J., Palmas W., Field L., Morin P., Goland R., Izquierdo R. E., Wolff L. T., Ashraf M., Hilliman C., Silver S., Meyer S., Holmes D., Petkova E., Capps L., Lantigua R. A.: A randomized trial comparing telemedicine case management with usual care in older, ethnically diverse, medically underserved patients with diabetes mellitus. J. Am. Med. Inform. Assoc. 2006, 3, 1, 40-51.
  • 16. Billiard A., Rohmer V., Roques M. A., Joseph M. G., Suraniti S., Giraud P., Limal J. M., Fressinaud P., Marre M.: Telematic transmission of computerized blood glucose profiles for IDDM patients. Diabetes Care 1991, 14, 2, 130-134.
  • 17. Albisser A. M., Harris R. I., Sakkal S., Parson I. D., Chao S. C.: Diabetes intervention in the information age. Med. Inform. (Lond.) 1996, 21, 4, 297-316.
  • 18. Bellazzi R., Arcelloni M., Bensa G., Blankenfeld H., Brugues E., Carson E., Cobelli C., Cramp D., D'Annunzio G., De Cata P., De Leiva A., Deutsch T., Fratino P., Gazzaruso C., Garcia A., Gergely T., Gomez E., Harvey F., Ferrari P., Hernando E., Boulos M.K., Larizza C., Ludekke H., Maran A., Nucci G., Pennati C., Ramat S., Roudsari A., Rigla M., Stefanelli M.: Design, methods, and evaluation directions of a multi-access service for the management of diabetes mellitus patients. Diabetes Technol. Ther. 2003, 5, 4, 621-629.
  • 19. Wójcicki J. M., Ładyżyński P., Krzymień J., Jóźwicka E., Blachowicz J., Janczewska E., Czajkowski K., Karnafel W.: What we can really expect from telemedicine in intensive diabetes treatment: results from 3-year study on type 1 pregnant diabetic women. Diabetes Technol. Ther. 2001, 3, 4, 581-589.
  • 20. Ładyżyński P., Wójcicki J. M., Krzymień J., Blachowicz J., Jóźwicka E., Czajkowski K., Janczewska E., Karnafel W.: Teletransmission system supporting intensive insulin treatment of out-clinic type 1 diabetic pregnant women. Technical assessment during 3 years' application. Int. J. Artif. Organs 2001, 24, 3, 157-163.
  • 21. Ładyżyński P., Wójcicki J. M.: Home telecare during intensive insulin treatment - metabolic control does not improve as much as expected. J. Telemed. Telecare 2007, 13, 1, 44-47.
  • 22. Larizza C., Bellazzi R., Stefanelli M., Ferrari P., De Cata P., Gazzaruso C., Fratino P., D'Annunzio G., Hernando E., Gomez E. J.: The M2DM Project-the experience of two Italian clinical sites with clinical evaluation of a multi-access service for the management of diabetes mellitus patients. Methods. Inf. Med. 2006, 45, 1, 79-84.
  • 23. Montani S., Bellazzi R., Quaglini S., d'Annunzio G.: Meta-analysis of the effect of the use of computer-based systems on the metabolic control of patients with diabetes mellitus. Diabetes. Technol. Ther. 2001, 3, 3, 347-356.
  • 24. Montori V. M., Helgemoe P. K., Guyatt G. H., Dean D. S., Leung T. W., Smith S. A., Kudva Y. C.: Telecare for patients with type 1 diabetes and inadequate glycemic control: a randomized controlled trial and meta-analysis. Diabetes Care 2004, 27 (5), 1088-1094.
  • 25. Viterion TeleHealth: http://www.viterion.com, Last accessed 15.06.2010.
  • 26. Health Buddy - Bosch: http://www.healthbuddy.com, Last accessed 15.06.2010.
  • 27. Farmer A., Gibson O., Hayton P., Bryden K., Dudley C., Neil A., Tarassenko L.: A real-time, mobile phone-based telemedicine system to support young adults with type 1 diabetes. Inform. Prim. Care 2005, 13, 3, 171-177.
  • 28. Ładyżyński P., Wójcicki J. M., Krzymień J., Foltyński P., Migalska-Musiał K., Tracz M., Karnafel W.: Mobile telecare system supporting intensive treatment and patients' education. First clinical application for newly diagnosed type 1 diabetic patients. Int. J. Artif. Organs 2006, 29, 11, 1074-1081.
  • 29. GlucoMON (Diabetech): http://mygluco.com, Last accessed 15.06.2010.
  • 30. Diabetes Phone (HelthPia): http://www.healthpia.us, Last accessed 15.06.2010.
  • 31. eHIT Ltd.: http://www.ehit.fi, Last accessed 15.06.2010.
  • 32. BodyTel Scientific Inc.: http://www.bodytel.com, Last accessed 15.06.2010.
  • 33. VitaBot Meal Planning System: http://vegandietadvisor.vitabot.com, Last accessed 15.06.2010.
  • 34. WeightMirror instant weight loss visualizer: http://www.weightmirror.com, Last accessed 15.06.2010.
  • 35. BodyMedia Ltd.: http://www.bodymedia.com, Last accessed 15.06.2010.
  • 36. Mignault D., St-Onge M., Karelis A. S., Allison D. B., Rabsa-Lhoret R.: Evaluation of the Portable Healthwear Armband: a device to measure total daily energy expenditure in free-living type 2 diabetic individuals. Diabetes Care 2005, 28, 1, 225-227.
  • 37. Sazonov E., Schuckers S., Lopez-Meyer P., Makeyev O., Sazonova N., Melanson E. L., Neuman M.: Non-invasive monitoring of chewing and swallowing for objective quantification of ingestive behavior. Physiol. Meas. 2008, 29, 525-541.
  • 38. Firmin H., Reilly S., Fourcin A.: Non-invasive monitoring of reflexive swallowing Speech Hear. Lang. 1997, 10, 171-184.
  • 39. Cooper D. S., Perlman A. L.: Electromyography in the functional and diagnostic testing of deglutition. In: K. Lourinia (Eds.), Deglutition and its Disorders: Anatomy, Physiology, Clinical Diagnosis and Management, Singular, London 1996, 255-285.
  • 40. Amft O., Tröster G.: Recognition of dietary activity events using on-body sensors. Artif. Intell. In Med. 2008, 42, 121-136.
  • 41. Hutchinson A., McIntosh A., Peters J., O'Keeffe C., Khunti K., Baker R., Booth A.: Effectiveness of screening and monitoring tests for diabetic retinopathy--a systematic review. Diabet. Med. 2000, 17, 7, 495-506.
  • 42. Scanlon P. H., Malhotra R., Thomas G., Foy C., Kirkpatrick J. N., Lewis-Barned N., Harney B., Aldington S. J.: The effectiveness of screening for diabetic retinopathy by digital imaging photography and technician ophthalmoscopy. Diabet. Med. 2003, 20, 6, 467-474.
  • 43. Zahlmann G., Walther H. D., Liesenfeld B., Kaatz H., Kluthe S., Fabian E., Klaas D., Schnarr K. D., Neubauer L., Obermaier M., Wegner A., Mertz M., Mann G.: Teleconsultation network for ophthalmology-experiences and results. Klin. Monatsbl. Augenheilkd 1998, 212, 2, 111-115.
  • 44. Bursell S. E., Cavallerano J. D., Cavallerano A. A., Clermont A. C., Birkmire-Peters D., Aiello L. P., Aiello L. M.: Joslin Vision Network Research Team: Stereo nonmydriatic digital-video color retinal imaging compared with Early Treatment Diabetic Retinopathy Study seven standard field 35-mm stereo color photos for determining level of diabetic retinopathy. Ophthalmology 2001, 108, 3, 572-585.
  • 45. Cavallerano J. D., Aiello L. P., Cavallerano A. A., Katalinic P., Hock K., Kirby R., Aiello L. M.; Joslin Vision Network Clinical Team: Nonmydriatic digital imaging alternative for annual retinal examination in persons with previously documented no or mild diabetic retinopathy. Am. J. Ophthalmol. 2005, 140, 4, 667-673.
  • 46. Hejlesen O., Ege B., Englmeier K. H., Aldington S., McCanna L., Bek T. TOSCA-Imaging - developing Internet based image processing software for screening and diagnosis of diabetic retinopathy. Medinfo, 2004; 11 (Pt 1): 222-226.
  • 47. Cuadros J., Bresnick G.: EyePACS: An adaptable telemedicine system for diabetic retinopathy screening. J. Diabetes. Sci. Technol. 2008, 2, 3, 509-516.
  • 48. Gomez-Ulla F., Fernandez M. I., Gonzalez F., Rey P., Rodriguez M., Rodriguez-Cid M. J., Casanueva F.F., Tome M.A., Garcia-Tobio J., Gude F.: Digital retinal images and teleophthalmology for detecting and grading diabetic retinopathy. Diabetes Care, 2002; 25, 8, 1384-1389.
  • 49. Ng M. C., Nathoo N., Rudnisky C. J. Tennant M. T. S.: Improving access to eye care: teleophthalmology in Alberta, Canada. J. Diabetes Sci. Technol. 2009, 3, 2, 289-296.
  • 50. Ładyżyński P., Wójcicki J. M., Chihara K.: Teletransmission system for effective support of recognition and monitoring of the diabetic retinopathy. Jap. J. Med. Electron. Biol. Eng. (BME), 2001, 15, 7, 30-38.
  • 51. Ładyżyński P., Wójcicki J. M., Chihara K.: Application of telemedicine technique in screening for diabetic retinopathy. Biocybern. Biomed. Eng. 2007, 27, 1-2, 253-263.
  • 52. Ładyżyński P., Wójcicki J. M., Chihara K.: Design and development of a web-based syste m for early recognition and monitoring of the diabetic retinopathy. In: M. Nyssen, G. Thienpont, J. Woodall, T. N. Arvanitis (Eds): Real World Medical Applications, IOS Press, Brussels 2000, 186-187.
  • 53. Armstrong D. G., Holtz-Neiderer K., Wendel C., Mohler M. J., Kimbriel H. R., Lavery L. A.: Skin temperature monitoring reduces the risk for diabetic foot ulceration in high-risk patients. Am. J. Med. 2007, 120, 12, 1042-1046.
  • 54. Caselli A., Latini V., Lapenna A., Di Carlo S., Pirozzi F., Benvenuto A., Uccioli L.: Transcutaneous oxygen tension monitoring after successful revascularization in diabetic patients with ischaemic foot ulcers. Diabet. Med. 2005, 22, 4, 460-465.
  • 55. Ablaza V., Fisher, J.: Telemedicine and wound care management. Home Care Provider 1998, 3, 4, 206-211.
  • 56. McGill M., Constantino M., Yue D. K.: Integrating telemedicine into a national diabetes footcare network. Practical Diabetes Int. 2000, 17, 7, 235-238.
  • 57. Clemensen J., Larsen S. B., Ejskjaer N.: Telemedical treatment at home of diabetic foot ulcers. J. Telemed. Telecare 2005; 11 (Suppl. 2), 14-16.
  • 58. Larsen S. B., Clemensen J., Ejskjaer N.: A feasibility study of UMTS mobile phones for supporting nurses doing home visits to patients with diabetic foot ulcers. J. Telemed. Telecare 2006, 12, 7, 358-362.
  • 59. Ładyżyński P., Wójcicki J. M., Foltyński P., Rosiński G., Krzymień J., Mrozikiewicz-Rakowska B., Migalska-Musiał K., Karnafel W.: Application of the home telecare system in the treatment of diabetic foot syndrome. In: Ch. T. Lim and J. C. H. Goh (Eds.), IFMBE Proc., Springer, Berlin, Heidelberg 2009, 23, 1049-1052.
  • 60. Foltyński P., Wójcicki J. M., Ładyżyński P., Migalska-Musiał K., Rosiński G., Krzymień J., Karnafel W.: Monitoring of the diabetic foot syndrome treatment. A new perspectives. Artif. Organs 2011, 35, 2, in press.
  • 61. Molik M., Foltyński P., Ładyżyński P., Tarwacka J., Migalska-Musiał K., Ciechanowska A., Sabalińska S., Młynarczuk M., Wójcicki J. M., Krzymień J., Karnafel W.: Comparison of the wound area assessment methods in the diabetic foot syndrome. Biocybern. Biomed. Eng. 2010, 30, 4, 3-14.
  • 62. Wound Measurement Device (Georgia Tech Research Corporation, USA): http://mobilityrerc.catea.org/factsheets/wmd_factsheet.pdf, Last accessed: 15.06.2010.
  • 63. Kundin J. I.: Designing and developing a new measuring instrument. Perioper. Nurs. Q. 1985, 1, 4, 40-45.
  • 64. Vincent 50 (MeDaVinci, Liverpool, UK): http://www.medgadget.com/archives /2009/09/vincent_50_no_pressure_foot_scanner_brings_safety_to_diabetic_feet.html, Last accessed: 15.06.2010.
  • 65. Ładyżyński P., Foltyński P., Wójcicki J. M., Migalska-Musiał K., Molik M., Krzymień J., Rosiński G., Opolski G., Czajkowski K., Tracz G., Karnafel W.: A new concept of the integrated care sernice for unstable diabetic patients. In: P. D. Bamidis and N. Pallikarakis (Eds.), IFMBE Proc., Springer, Berlin, Heidelberg 2010, 29, 932-934.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPZ1-0069-0007
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.