EN
X-Ray imaging is a tool used for non-destructive inspection of the internal structure of products and measurements of geometric dimensions of products of any shape. The non-destructive nature of measurement techniques using X-Rays has enormous potential for wide application in many industries. At the Institute for Sustainable Technologies - National Research Institute in Radom, a universal research system for modelling X-Ray imaging methods was designed and manufactured, which was intended for performing automatic inspection of products using X-Rays. The developed system will be used in research and development works carried out jointly with industrial partners to develop innovative product inspection systems. The article describes the mechanical structure of the device, the control system, the ranges of parameters at which it is possible to carry out inspections of products using X-Rays, as well as exemplary test results.
PL
Obrazowanie rentgenowskie jest narzędziem wykorzystywanym do nieniszczącej kontroli wewnętrznej struktury wyrobów oraz pomiarów wymiarów geometrycznych produktów o dowolnych kształtach. Nieniszczący charakter technik pomiarowych wykorzystujących promieniowanie rentgenowskie ma ogromny potencjał do szerokiego zastosowania w wielu gałęziach przemysłu. W Instytucie Technologii Eksploatacji - Państwowym Instytucie Badawczym w Radomiu zaprojektowano i wytworzono uniwersalny system badawczy modelowania metod obrazowania X-Ray, przeznaczony do wykonywania automatycznej inspekcji wyrobów z wykorzystaniem promieniowania rentgenowskiego. Opracowany system zostanie wykorzystany w pracach badawczo-rozwojowych realizowanych wspólnie z zakładami przemysłowymi w celu opracowania innowacyjnych systemów inspekcji wyrobów. W artykule opisano konstrukcję mechaniczną urządzenia, system sterowania, podano zakresy parametrów, przy których możliwe jest prowadzenie inspekcji wyrobów z wykorzystaniem promieniowania rentgenowskiego, a także przedstawiono przykładowe wyniki badań.
Twórcy
  • Institute for Sustainable Technologies - National Research Institute, Radom, Poland
  • Institute for Sustainable Technologies - National Research Institute, Radom, Poland
  • Institute for Sustainable Technologies - National Research Institute, Radom, Poland
Bibliografia
  • 1. du Plessis A., Boshoff W.P.: A review of X-ray computed tomography of concrete and asphalt construction materials. Construction and Building Materials, 2019, 199, pp. 637-651.
  • 2. De Chiffre L., Carmignato S., Kruth J.-P., Schmitt R., Weckenmann A.: Industrial applications of computed tomography. CIRP Annals, 2014, 63(2), 2014, pp. 655-677.
  • 3. Kastner J., Plan B., Heinzl Ch.: Advanced X-ray computed tomography methods: High resolution CT, quantitative CT, 4DCT and phase contrast CT. In: Digital Industrial Radiology and Computed Tomography (DIR 2015) 22-25 June 2015, Belgium, Ghent. Proceedings, 2015, pp. 120-132.
  • 4. Kastner J., Heinzl Ch., Plank B., Salaberger D., Gusenbauer Ch., Senck S.: New X-ray computed tomography methods for research and industry. In: 7th Conference on Industrial Computed Tomography, Leuven, Belgium (iCT 2017). Proceedings, 2017.
  • 5. Hubbell J., Seltzer S.: Tables of X-Ray mass attenuation coefficients and mass energy-absorption coefficients from 1 keV to 20 MeV for elements Z = 1 to 92 and 48 Fig. 12. Illustration of analytic potential of integrated software additional substances of dosimetric interest. [Online]. 1996. [Accessed 12 March 2019]. Available from: http://www.nist.gov/pml/data/xraycoef/index.cfm
  • 6. Mery D.: Computer Vision Technology for X-ray Testing. Insight, 2014, 56(3), pp. 147-155.
  • 7. BECKHOFF: XTS – The linear transport system, technical documentation.[Online]. 2019. [Accessed 19 March 2019].Available from: https://beckhoff.pl/XTS
  • 8. EtherCAT Technology Group: EtherCAT organization website. [Online]. 2019. [Accessed 19 March 2019]. Available from: https://www.ethercat.org
  • 9. BECKHOFF: Safety over EtherCAT - Description of technology, manufacturer website. [Online]. 2015. [Accessed 19March 2019].Available from: https://www. beckhoff.com/english.asp?ethercat/soe_technology.htm
  • 10. BECKHOFF: TwinSAFE, manufacturer website. [Online]. 2018. [Accessed 19 March 2019]. Available from: https://www.beckhoff.com/english. asp?twinsafe/twinsafe-integrated-logic.htm
  • 11. X-ray TDI Camera C12300-321 Instruction Manual. Hamamatsu Photonics K.K., 2016.
  • 12. IXS060BP800P378 X-Ray generator specification. A VJ Technologies Company, 2017.
  • 13. Active Silicon: Phoenix Camera Link Frame Grabber (D24-PE1), technical documentation. [Online]. 2019. [Accessed 19 March 2019]. Available from: https://www.activesilicon.com/products/phoenixcamera-link-frame-grabber-D24-PE1
  • 14. Wong H.-S., Yao Y.L., Schlig E.S.: TDI chargecoupled devices: Design and applications. Ibm Journal of Research and Development, 1992, 36, pp. 83-106.
  • 15. Humamatsu: X-ray TDI camera C12300-321, manufacturer website. [Online]. 2017. [Accessed 19March 2019].Available from: https://www.hamamatsu.com/resources/pdf/sys/SFAS0034E_C12300.pdf
Uwagi
Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2019).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-ad133979-8781-45fd-85d8-cc3a626d04d4
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.