Comparative analysis of SOCON CS screws in treatment of osteoporotic vertebral fractures

Identyfikatory
Warianty tytułu
CS
Srovnavaci analyza SOCON CS sroubu pouzivanych pri oseteeni osteoporotickych zlomenin obratlu
Konferencja
International Seminar of Applied Mechanics (12 ; 13-15.06.2008 ; Wisła, Polska)
Języki publikacji
EN
Abstrakty
EN
The article focuses on the effect of transpedicular cemented and non-cemented screws applied in osteoporotic vertebrae and on the stability of connection between the bone and screw when subjected to extraction test. Cemented and non-cemented screws were inserted in experimental vertebral samples and extracted using a standard testing device. The obtained results prove that the extraction force in cemented screws is significantly higher than in non-cemented screws (t-test, p-value = 0.007).
CS
Příspěvek se zabývá posouzením transpedikulárních cementovaných a necementovaných šroubů aplikovaných do kadaverózního osteoporotického obratle; pevnost spojení kost - šroub jsme hodnotili při vytrhávací zkoušce. Do zkušebních vzorků obratlů byly aplikovány cementované a necementované šrouby a na zkušebním stroji vytrženy. Naměřené výsledky potvrzují, že vytrhávací síla je pro cementované šrouby statisticky významně vyšší než pro necementované (t-test, p-value = 0,007).
Rocznik
Tom
Strony
75--78
Opis fizyczny
Bibliogr. 1 poz
Twórcy
autor
  • Centre of Mechatronics - Institute of Thermomechanics Academy of Sciences of the Czech Republic and Institute of Solid Mechanics, Mechatronics and Biomechanics, Faculty of Mechanical Engineering, Brno University of Technology
  • Spinal Unit, Trauma Hospital of Brno, Ponavka 6, 662 50 Brno, Czech Republic
autor
  • Institute of Solid Mechanics, Mechatronics and Biomechanics, Faculty of Mechanical Engineering, Brno University of Technology
autor
  • Spinal Unit, Trauma Hospital of Brno, Ponávka 6, 662 50 Brno, Czech Republic
autor
  • Centre of Mechatronics - Institute of Thermomechanics Academy of Sciences of the Czech Republic and Institute of Solid Mechanics, Mechatronics and Biomechanics, Faculty of Mechanical Engineering, Brno University of Technology
Bibliografia
  • 1. Seedbeck J., Goldhahn J., Morlock M.M., Schneider E., Mechanical behavior of screws in normal and osteoporotic bone, Osteoporos Int (2005) 16: S107-S111.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-3a6a3b08-22a5-4224-bc79-57b82b363cbc
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.