Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  MCNP5
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
100%
Nukleonika
|
2015
|
tom 60
|
nr 1
171-179
EN
An analysis of the influence of addition of minor actinides (MA) to the fast reactor fuel on the most important safety characteristics was performed. A special emphasis was given to the total control rods worth in order to describe qualitatively and quantitatively its change with MA content. All computations were performed with a homogeneous assembly model of modified BN-600 sodium-cooled fast reactor core with 0, 3 and 6% of MA. A model was prepared for the Monte Carlo neutron transport code MCNP5 for fresh fuel in the beginning-of-life (BOL) state. Additionally, some other parameters, such as Doppler constant, sodium void reactivity, delayed neutron fraction, neutron fluxes and neutron spectra distribution, were computed and their change with MA content was investigated. Study indicates that the total control rods worth (CRW) decreases with increasing MA inventory in the fuel and confirms that the addition of MA has a negative effect on the delayed neutron fraction.
EN
An analysis of the infl uence of addition of minor actinides (MA) to the fast reactor fuel on the most important safety characteristics was performed. A special emphasis was given to the total control rods worth in order to describe qualitatively and quantitatively its change with MA content. All computations were performed with a homogeneous assembly model of modifi ed BN-600 sodium-cooled fast reactor core with 0, 3 and 6% of MA. A model was prepared for the Monte Carlo neutron transport code MCNP5 for fresh fuel in the beginning-oflife (BOL) state. Additionally, some other parameters, such as Doppler constant, sodium void reactivity, delayed neutron fraction, neutron fl uxes and neutron spectra distribution, were computed and their change with MA content was investigated. Study indicates that the total control rods worth (CRW) decreases with increasing MA inventory in the fuel and confi rms that the addition of MA has a negative effect on the delayed neutron fraction.
3
Content available remote Dosimetry of two new interstitial brachytherapy sources
88%
EN
With increased demand for low 103Pd (palladium) seed sources, to treat prostate and eye cancers, new sources have been designed and introduced. This article presents the two new palladium brachytherapy sources, IR03-103Pd and IR04-103Pd that have been developed at Nuclear Science and Technology Research Institute. The dosimetry parameters such as the dose rate constant Λ, the radial dose function g(r), and the anisotropy function F(r,θ), around the sources have been characterized using Version 5 Monte Carlo radiation transport code in accordance with the update AAPM Task Group No. 43 report (TG-43U1). The results indicated the dose rate constant of 0.689±0.02 and 0.667±0.02 cGy h-1 U-1 for the IR03-103Pd and IR04-103Pd sources respectively, which are in acceptable agreement with other commercial seeds. The calculated results were compared with published results for those of other source manufacturers. However, they show an acceptable dose distribution, using for clinical applications is pending experimental dosimetry.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.