Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  Chromium
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
Open Chemistry
|
2012
|
tom 10
|
nr 4
927-937
EN
Chromium is one of the regulated toxic metals in the environment. Naturally, this element exists mainly in two oxidation: Cr(III) and Cr(VI). In general, Cr(VI) is more toxic than Cr(III). Cr(VI) affects human physiology, accumulates in the food chain and causes severe health problems ranging from simple skin irritation to lung carcinoma. Hence, the determination of chromium traces as well as its speciation in environmental samples is a very important task. In recent years, several preconcentration methods such as coprecipitation, liquid-liquid extraction, dispersive liquid-liquid microextraction, cloud point extraction, and solid phase extraction have been developed and widely used. The aim of this study is to review the recent literature (mainly last 5 years) on the preconcentration technologies those have been used in chromium removal before the determination step by atomic spectrometric techniques. Their advantages and limitations in application are also evaluated.
2
Content available remote On chromium direct ETAAS determination in serum and urine
100%
EN
A simple, accurate and reliable method for direct electrothermal atomic absorption spectrometric (ETAAS) determination of chromium in serum and urine samples without any preliminary sample pretreatment is described. Instrumental parameters are optimized in order to define: the most suitable atomizer, optimal temperature program and efficient modifier. An appropriate quantification method is proposed taking into account a matrix interference study. Pyrocoated graphite tubes and wall atomization, pretreatment temperature of 700 °C, atomization temperature of 2600 °C, hydrogen peroxide as modifier and standard addition calibration are recommended. The accuracy of the method proposed for Cr determination in serum and urine was confirmed by comparative analysis of parallel samples after wet or dry ashing as well as by the analysis of two certified reference materials: Serum, Clin Rep 1 and Lypochek Urine, level 1. The detection and determination limits achieved for both matrices are 0.08 µg/L and 0.15 µg/L respectively. The relative standard deviation varied between 15 and 18 % for the chromium content in the samples in the range 0.08–0.2 µg/L and between 4 and 7 % for the chromium content in the range 0.2–2.0 µg/L for both matrices. [...]
3
Content available remote Strategy of Cr detoxification by Callitriche cophocarpa
88%
EN
The present work focused on the qualitative and quantitative analysis of Cr detoxification strategy of aquatic cosmopolitan plant Callitriche cophocarpa. This plant species has just been described in the context of its unusual accumulation potential of Cr. The emphasis of the work was placed on the redox reaction Cr(VI)→Cr(III) which is considered to be remediation mechanism of highly reactive and mobile Cr(VI) ions. Plants were immersed for 5 days in 1 mM of Cr(VI) (potassium dichromate) or 1 mM of Cr(III) (chromium sulphate) solutions in semi-natural conditions. Cr was effectively removed from the solution up to the extent of ca.58% or 35% of the starting amount, in the case of Cr(III) and Cr(VI), respectively. No plant-induced Cr(VI) reduction accompanying Cr accumulation was observed in Cr(VI) solutions except from the apparent one, noticed at the fourth day of incubation. On the contrary to these results, according to the method of electron paramagnetic resonance spectroscopy (L-band EPR), biphasic signal of Cr(V) attending Cr(VI) to Cr(III) reduction was detected inside the plant tissue every day of investigations. Our results show that phytoextraction but not phytostabilization is the main strategy of Cr detoxification by C. cophocarpa in aquatic systems. [...]
4
Content available remote Modelling and optimization of chromiumIII biosorption on soybean meal
88%
EN
Abstract In this investigation a waste biological material, soybean meal, was applied as a biosorbent for heavy metal ions (CrIII). The diffusive Webber-Morris model and the pseudo-II-order model suitably described the kinetics of CrIII ions binding on soybean meal. The Langmuir-Freundlich equation was valid for the description of the isotherm. Inductively coupled plasma optical emission spectroscopy (ICP-OES), FTIR and scanning electron microscopy with an energy dispersive X-ray analytical system (SEM-EDX) were used in order to identify the mechanism of the metal ions binding. The analysis of the composition of the enriched soybean meal confirmed the contribution of ion exchange in the biosorption process. Three-variable-three-level Box-Behnken design was used to determine the optimal conditions for biosorption of CrIII on soybean meal. The optimal conditions for predicted maximum Cr3+ uptake (61.07 mg g−1) by soybean meal were estimated by Matlab and established as temperature of 38.04°C, initial metal concentration 500 mg L−1 and biosorbent dosage 1 g L−1. Graphical abstract [...]
EN
Determination of cadmium, lead, chromium and nickel in soil samples by slurry sampling graphite furnace atomic absorption spectrometry (GFAAS) was presented. Optimization of determination conditions, stability test for slurries and metal partitioning between solid and liquid phase was investigated. The method was successfully tested by the analysis of certified reference materials.
6
51%
EN
Novel Calix[4]arene Netwok (NCN) resin has been synthesized using Amberlite XAD-2 as the starting material. Hydroxyl groups have been introduced onto the para position of alkylated phenyl ring of Amberlite XAD-2 followed by the condensation to NCN by reacting it with formaldehyde. The NCN resin has been used for the remediation of Cr(VI) contaminated water using factorial design approach. A face-centered Draper-Lin composite design predicted ~100% removal effi ciency at optimum variables (the initial concentration of Cr(VI) ion 10 mg/l sorbent dose 200 mg, agitation time 136 min and pH 2). The accuracy and the fi tting of the model were evaluated by ANOVA and R2 (0.9992) values. The 99.5% removal effi ciency has been achieved experimentally at the optimum values of the variables. The Langmuir and D-R isotherm models were applicable to the sorption data with the value of RL and the sorption free energy 0.0057-0.1 and 7.93 kJ/mol respectively, suggesting favorable and physical/ion-exchange nature of the sorption. The calculated sorption capacity was 176.1±2.4 mg/g. The recycling studies of NCN resin showed that the multiple use of resin is feasible. Effect of concomitants has also been studies and proposed method was applied successfully for removal (98.7%) of Cr (VI) from electroplating wastewater.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.