Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
A review of the available literature shows that analyses of organic Rankine cycle systems with a zeotropic mixture working medium practically concern single-circuit systems. In these works, it has been shown that the standing of zeotropic mixtures in organic Rankine cycle systems makes it possible to achieve higher power and efficiency compared to organic Rankine cycle systems with pure fluids. In this article, the authors present an analysis of the efficiency of a two-circuit organic Rankine cycle (binary) power plant with a zeotropic mixture in the upper cycle of this power plant. The proposed binary power plant system uses a zeotropic mixture circulating medium in the upper organic Rankine cycle circuit, while the lower circuit uses a homogeneous low-boiling medium. The results of this analysis showed that with properly selected parameters of the binary power plant system, i.e. with appropriate selection of the pressure during the evaporation transformation in the upper and lower circuits, the power obtained in it is higher than for a single-circuit power plant in the same temperature range (for the same heat source and the same condensing temperature). The increase in the power of the binary power plant system was achieved by using the heat contained in the water stream to preheat the medium in the bottom circuit. For example, for the binary organic Rankine cycle power plant with R413A refrigerant in the upper circuit, the generated power is 17.8 kWe, which is 20% higher than for a single-circuit power plant (for the reference power plant, the power is 14.8 kWe).
EN
The article discusses issues related to the assessment of pollutant emissions from a railbus during transport work. The test object was a rail vehicle equipped with two diesel engines with a total power of 780 kW, Stage IIIB homologated. Measurements were carried out on the route Poznań-Wągrowiec in two directions. During the tests, the vehicle performed a transport service, where the number of passengers was counted. For the completed cycles, the average number of people was 82 and 18. Based on the obtained data, the vehicle operating conditions and emission indicators were analyzed, which were related to the number of passengers. A dimensionless toxicity index was also determined.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.