W artykule przedstawiono wyniki badań ścian skrępowanych (6 modeli) wykonanych z elementów murowych z autoklawizowanego betonu komórkowego (ABK). Wymiary zewnętrzne ścian wynosiły: grubość t = 0,18 m, długość l = 4,43 m, wysokość h = 2,49 m. Ściany badano przy wstępnych naprężeniach ściskających σc = 0,1; 0,75 i 1,0 N/mm2. Skrępowanie wykonano w postaci dwóch zewnętrznych pionowych rdzeni i dwóch poziomych rygli, które zazbrojono zgodnie z wymaganiami PN-EN-1996-1-1. Analizowano morfologię zarysowań ścian i mechanizm zniszczenia elementów.
EN
The paper presents the results of confined (6 walls) made of masonry elements with AAC. Overall dimensions were: thickness t = 0.18 m, length l = 4.43 m and the height of h = 2.43 m. The walls were tested at initial compressive stresses perpendicular to the plane of the bed joints σc = 0,1; 0,75; and 1,0 N/mm2. In the confined models two external vertical cores and two horizontal beams were made, which were reinforced in accordance with the requirements of PN-EN-1996-1-1. The morphology of cracking and the mechanism of destruction were analyzed.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule przedstawiono wyniki naprężeń rysujących i niszczących sześciu ścian skrępowanych ścinanych poziomo wykonanych z elementów murowych z ABK. Wymiary zewnętrzne ścian wynosiły: grubość t = 0,18 m; długość l = 4,43 m; wysokość h = 2,49 m. Ściany badano przy wstępnych naprężeniach ściskających σc = 0,1; 0,75 i 1,0 N/mm2. Analizowano wartości naprężeń rysujących i niszczących w odniesieniu do wyników badań ścian niezbrojonych, zbrojonych stalowymi kratowniczkami i siatkami z tworzywa sztucznego.
EN
The paper presents the results of cracking and ultimate shear stresses of 6 confined walls made of AAC masonry units. The external dimensions of the walls were: thickness t = 0.18 m; length l = 4.43 m; height h = 2.49 m. The walls were tested at initial compressive stresses equal to σc = 0.1; 0.75 and 1.0 N/mm2. The values of cracking and ultimate shear stresses were analyzed in relation to the results of tests of unreinforced walls, walls reinforced with steel trusses and plastic grid.
The aim of the study was to compare the physical and mechanical properties of known prostheses for cranioplasty: knitted Codubix based on polypropylene and Modela-cryl resin based on PMMA. It was expected that the study would allow to check whether it is possible to combine their properties, which should enable the preparation of a new material with properties combining the best features of both components. Physico-chemical and mechanical properties were evaluated. It was found that the two materials meet the requirements for chemical purity, ensuring the safety of their use. Regarding the mechanical properties, the energy of impact diffusion for two types of prostheses was determined applying the Drop Tower technique. The polymerisation heat of Modela-cryl resin was determined in real time using the DSC technique.
PL
Celem pracy było porównanie właściwości fizycznych i mechanicznych znanych protez do kranioplastyki: dzianej Codubix na bazie polipropylenu i żywicy Modela-cryl na bazie PMMA. Oczekiwano, że badanie pozwoli sprawdzić, czy możliwe jest połączenie ich właściwości, co powinno pozwolić na przygotowanie nowego materiału o właściwościach łączących najlepsze cechy obu komponentów. Oceniono właściwości fizykochemiczne i mechaniczne. Stwierdzono, że oba materiały spełniają wymagania czystości chemicznej, zapewniając bezpieczeństwo ich stosowania. Jeśli chodzi o właściwości mechaniczne, określono energię dyfuzji uderzeniowej dla dwóch typów protez przy użyciu techniki Drop Tower. Określono ciepło polimeryzacji żywicy Modela-cryl w czasie rzeczywistym za pomocą techniki DSC.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.