Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 10

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The analysis of the Adaptive Weight Smoothing (AWS) and the Discrete Wavelet Transform (DWT) application in the MRI images improvement is presented. The results show how the AWS and the DWT algorithms can be used for the noise reduction in the MRI. The DWT application gives much better visual results without blurring. It is shown that for the DWT a bigger number of the input parameters (like the wavelet’s choice, number of the iteration, degree of the decomposition, kind of the smoothing thresholding etc.) is needed, what makes it more difficult to optimize the output image. The analysis of the Signal to Noise Ratio (SNR) and the Contrast to Noise Ratio (CNR) and edge quality detection for both methods is presented to show their effectiveness. We concluded that the AWS algorithm can be applied to improve MRI images mainly in the case of high noise and low Signal to Noise Ratio (SNR) whereas wavelet transform is effective in any case. The wavelet transform application provides additional possibilities like image compression and image fusion, which can be useful in the MRI.
PL
Rozwój obrazowania magnetyczno-rezonansowego (OMR) skupia się na zastosowaniu wysokopolowych systemów OMR, jednak w wielu przypadkach diagnostyka medyczna w niskim polu magnetycznym umożliwia uzyskanie porównywalnych rezultatów. Zastosowanie tego typu systemów wymaga użycia dedykowanych cewek wysokiej częstości (w.cz.) w celu uzyskania maksymalnego stosunku sygnału do szumu (SNR). Wykorzystując m.in. analizy numeryczne, zaprojektowano oraz skonstruowano objętościowe, a także powierzchniowe cewkiw.cz., których przydatność do OMR została określona przy pomocy pomiarów testowych oraz obrazów MR uzyskanych dla fantomów. Przeprowadzone eksperymenty wykazały możliwość zastosowania cewek innych typów niż cewki solenoidalne, stosowane dotychczas do obrazowania w bardzo niskim polu magnetycznym.
EN
Recent advancements in magnetic resonance imaging (MRI) are mostly directed towards high-field imaging hardware, rapid pulse sequences and multiple channel phased array coils. Nonetheless, for many diagnostic tests performed using MRI, low-field scanners also provide sufficient quality of images. Using these types of systems requires special dedicated radiofrequency coils (RF coils) in order to achieve the highest possible signal to noise ratio (SNR) for a given magnetic field strength. This work describes the process of designing and constructing transceiver RF coils for a 0,088 T MRI system. Two volume and two surface coils were built and their performance was tested on the bench and through comparing the simulated magnetic field created by each coil with experimentally collected results from phantom MR images. Experiment proved that it is possible to use successfully different RF coils, than the most frequently used solenoid design for MRI at 0,088 T.
4
Content available remote Wodór w związkach międzymetalicznych typu faz Lavesa ziem rzadkich z manganem
100%
PL
Wśród związków międzymetalicznych ziem rzadkich i itru z metalami przejściowymi pochłaniających wodór szczególnie interesujące są związki typu faz Lavesa z manganem. W związkach tych pod wpływem wodoru zachodzą strukturalne i magnetyczne przemiany fazowe oraz zmiany ich właściwości. W pracy przedstawiono i omówiono obserwowane zjawiska dla wodorków REMn2Hx (RE = Y, Gd, Tb, Dy, Ho, Nd, Sm i Er) wskazując ich zależność od temperatury, rodzaju ziemi rzadkiej i koncentracji wodoru.
EN
A review with 34 refs. covering (Y, Gd, Tb, Dy, Ho, Nd, Sm, or Er)Mn2Hx hydrides, their prepn., Laves phases, structure and H-induced modifications, increase in vol. and magnetic properties in relation to H concn., crit. behavior, diffusion and ordering of H, and formation of the hydrides at pressures of up to 20 GPa.
5
Content available remote Energetyka wodorowa w Polsce [Listy do redakcji]
100%
EN
Currently, the metal-organic frameworks (MOF s) are considered among the most promising materials for hydrogen storage. In this paper, the properties of MOF s that are particularly important for application purposes are presented. Examples include simplicity of their syntheses on an industrial scale, low synthesis costs, high thermal stability and durability, an excellent repeatability and very low degree of degradation during cyclic hydrogen loading and recovery. On the other hand, the potential use of MOF s as hydrogen reservoirs is to some extent limited due to the fact that the low temperatures of 77 K are required for effective adsorption of hydrogen in the microporous structures of MOF s. Nowadays, the research on MOF s is carried in two directions. In particular, there are intensive studies on increasing of the concentration of hydrogen adsorbed at low temperatures in order to determine the limiting value for which maintaining the reservoir at the temperature of liquid hydrogen would be economically viable. It seems that the limiting concentration is being currently reached. The second direction of research is to increase the limiting value of temperature at which the concentration of adsorbed hydrogen is acceptable.
EN
The Cu-10 wt %Co melt spun ribbons with giant magneto-resistance (GMR) properties were aged at 773 K for 0.5, 1, 2, 4, 16 and 32 hours. Quantitative transmission electron microscopy (TEM) microstructural analysis have been carried out to determine size distributions of beta -Co precipitates. The results of magnetisation, coercitivity and electrical magneto-resistivity measurements were correlated with the mean diameters of coherent beta-Co particles. It was shown, that the maximum GMR is achieved for the mean diameters of beta-Co particles less than 10 nm, whereas for larger particles the GMR effect is strongly reduced.
PL
Otrzymane metodą krystalizacji z ciekłej strugi taśmy stopu Cu-10% wag.Co, wykazującego gigantyczny magnetoopór, wyżarzono w temperaturze 773 K przez 0,5, 1, 2, 4, 16 i 32 godziny. W celu określenia rozkładów wielkości wydzieleń beta--Co po różnych wariantach wyżarzania przeprowadzono ilościową analizę mikrostruktury metodami transmisyjnej mikroskopii elektronowej. Wyniki pomiarów namagnesowania, koercji i magnetooporu skorelowano z wartościami średniej średnicy koherentnych wydzieleń beta-Co. Wykazano, że stop wykazuje maksymalny magnetoopór, gdy średnia średnica wydzieleń jest mniejsza niż 10 nm. Wzrost średniej wydzieleń powyżej 10 nm sprawia, że efekt magnetooporu wyraźnie maleje.
EN
The Transmission Electron Microscopy investigations of the Cu90Co10 ribbons are presented and discussed. The ribbons obtained by melt spinning were annealed at 550 degrees centigrade for 1; 2; 4 and 16h. The structure with coherent Co precipitates is observed, and the mean size of the precipitates increases according to ageing time.
9
Content available remote Nanokompozyty magnetyczne dla zastosowań medycznych
70%
PL
Nanokompozyty polimerowe to perspektywiczna grupa tworzyw o unikatowych właściwościach. Materiały te znajdują zastosowanie w wielu dziedzinach w tym również w medycynie. W pracy przedstawiono prostą metodę wytwarzania nanokompozytów o właściwościach magnetycznych, polegającą na kilkuetapowej homogenizacji obydwu składników; roztworu polimeru oraz cząstki magnetycznej. Nanokompozyty polimerowe scharakteryzowano w zakresie właściwości mechanicznych, termicznych, magnetycznych oraz biologicznych. Wykazano, że magnetyczne nanokompozyty na bazie polisulfonu to nietoksyczne materiały o właściwościach magnetycznych, zależnych od ilości modyfikatora, wprowadzonego do matrycy polimerowej. Magnetyczne nanokompozyty są materiałem, mogącym znaleźć zastosowanie w konstrukcji membran i implantów, przeznaczonych do terapii i diagnostyki medycznej.
EN
Polymer nanocomposites are a prospective group of materials with unique properties. These materials are used in many fields including the medicine. The paper presents a simple method of producing nanocomposites with magnetic properties, which consists of several stages of homogenization of the two components; polymer solution and magnetic particles. Mechanical, thermal and magnetic properties of the obtained polymer nanocomposite were determined. Biological assessment proved that the nanocomposite samples are nontoxic and their magnetic properties depend on the amount of the nanontagnetic phase in the polymer matrix. The magnetic nanocomposites may find application in the manufacturing of membranes and implants for medical diagnosis and therapy.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.