Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Novel modified non-isolated DC-DC boost converter based on voltage lift technique
100%
EN
In this paper, a novel DC-DC boost converter based on the voltage lift technique is manifested. It is firmly reasoned that, with a lesser number of elements, the proposed converter can yield analogously high voltage gain than that of the recently published DC-DC boost converters. The proposed converter is anticipated to provide higher efficiency due to its substantial voltage gain at a comparatively low duty cycle. Finally, to validate the acquired simulation results, a small-scale laboratory prototype is implemented and compared with the theoretical interpretation.
PL
Przedstawiono nowy przekształtnik DC-DC typu boost bazujący na technice voltage lift. Przy mniejszej liczbie elementów yen przekształtnik ma on lepsze parametry niż przekształtniki opisywane w literaturze. Skonstruowano i zbadano prototyp przekształtnika.
2
Content available remote Amelioration of ship control with improved dynamic response of motor controller
100%
EN
During a sea voyage, it is significantly important to fix the speed and angle of movement of the ship precisely depending on the distance of the destination and also in icebreaking purpose. So, enhancement of transient response of commutator motor used in the ship is essential. Due to their better reliabilities as well as low costing, nowadays, Direct Current (commutator) motors are utilized in icebreaking ships, in industrial near and far applications, robotic manipulators, and also for home appliances. Thus, it is vital to introduce a suitable controller for managing the speed and transient behavior of a Direct Current. In this study, for the enhancement of dynamic response, various DC commutator motor controllers have been simulated. At first, the DC commutator motor parameters are selected and four optimized controllers: Ziegler-Nichols (ZN)-based conventional Proportional Integral Derivative (PID) controller, Genetic Algorithm (GA)-based PID controller (GA-PID), as well as Flower Pollination Algorithm (FPA)-based PID (FPA-PID) are designed and simulated to manage the angular speed together with dynamic response of shaft of a Direct Current commutator motor actuator. The electric actuator response for every controller is ascertained as well as compared after applying step input that is necessary for the simulation of transient response of the motor. The performance analysis shows that the FPA-PID controller is adequate for the steering task in the ship, which requires precision and associated with transient response properties.
PL
W artykule analizowano różne metody sterowania silnikiem komutacyjnym DC. Szczególną uwagę poświęcono sterownikom PID , PID wspomaganym algorytmami genetycznymi oraz Flower Pollination FPA-PID. . Analizowano możliwości sterowania prędkością przy odpowiednich parametrach dynamicznych. (odpowiedź na wymuszenie skokowe). Stwierdzono, że najlepsze właściwości do sterowani silnikiem statku ma algorytm FPA-PID.
EN
A new topology of single–phase AC-DC Buck-Boost converter is presented in this paper. The proposed converter provides conversion efficiency as high as 99.29% for open loop operation. Proposed converter with feedback controller can provide quality power factor (0.98) and reduced input current THD (16%) for average 1000V DC output voltage. Dynamic response of the proposed converter has also been observed for sudden changes of load. Analysis and simulation results of the circuit are obtained using software simulation.
PL
Zaproponowana nową topologię jednofazowego przekształtnika DC-DC typu buck-boost. W stanie jałowym konwersja jest rzędu 99,29%. Zaproponowany konwerter ma dużą skuteczność, małe zniekształcenia prądu I dobrą dynamikę.
4
80%
EN
A new topology of single–phase single switch non-isolated AC-DC Zeta converter is presented in this paper. The proposed topology in open loop operation can provide high conversion efficiency under duty cycle variation. Proposed converter with feedback controller provides high input power factor of 0.99 and reduced input THD while maintaining 900V DC output voltage. The converter exhibits stable dynamic response for sudden load change. Analysis and simulation results of the circuit are obtained using software simulation.
PL
W artykule przedstawiono nową topologię jednofazowego, jednoprzełącznikowego nieizolowanego przekształtnika AC-DC Zeta. Proponowana topologia w pracy w otwartej pętli może zapewnić wysoką wydajność konwersji przy zmianach cyklu pracy. Proponowany przekształtnik z kontrolerem sprzężenia zwrotnego zapewnia wysoki współczynnik mocy wejściowej 0,99 i zmniejszone THD wejściowe przy zachowaniu napięcia wyjściowego 900 V DC. Przetwornik wykazuje stabilną dynamiczną odpowiedź na nagłą zmianę obciążenia.
5
Content available remote Design and analysis of passive LC3 component Boost-SEPIC Converter
80%
EN
A cascaded DC-DC LC3 Boost-SEPIC converter is proposed and analyzed in this paper. In addition, the AC-DC topology and closed-loop topology of the converter are explored. The proposed DC-DC converter is capable of delivering maximum efficiency of 98.06%. For the AC-DC topology of the proposed converter, the peak efficiency of the converter is 97.77%. With the use of a controller, the performance of the AC-DC topology improved. Input THD reduced to 11.05%, and the input power factor of the converter increased to 0.983. Load analyses of both DC-DC and AC-DC topologies of the proposed converter are also carried out. Simulations of the converter are conducted using PSIM 12.0 software to facilitate the results.
PL
W artykule zaproponowano i przeanalizowano kaskadowy konwerter DC-DC LC3 Boost-SEPIC. Ponadto badana jest topologia ACDC i topologia pętli zamkniętej konwertera. Proponowany konwerter DC-DC jest w stanie zapewnić maksymalną sprawność 98,06%. Dla topologii AC-DC proponowanego konwertera, szczytowa sprawność konwertera wynosi 97,77%. Dzięki zastosowaniu kontrolera poprawiono wydajność topologii AC-DC. THD wejściowe zmniejszono do 11,05%, a współczynnik mocy wejściowej konwertera wzrósł do 0,983. Przeprowadzane są również analizy obciążenia zarówno topologii DC-DC, jak i AC-DC proponowanego przekształtnika. Symulacje konwertera są przeprowadzane przy użyciu oprogramowania PSIM 12.0, aby ułatwić uzyskanie wyników.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.