Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 7

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  water repellent
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
100%
EN
Inhalation of fluorocarbon polymers can cause pulmonary toxicity. Although multiple cases of lung injury have been reported, cellular characterization of the associated alveolitis occurring acutely after inhalation is limited. We report the case of a previously healthy woman who presented at our Emergency Department with an acute pneumonitis following inhalation of a fluorocarbon polymer-based rain-proofing spray. Bronchoalveolar lavage (BAL) performed shortly after the presentation showed an elevated total cell count, with a high proportion of neutrophils (58%) and eosinophils (9%). In addition, a lipid stain (Oil-Red-O-stain) showed a high level of lipid laden macrophages, a marker that could reflect a direct toxic effect of the spray on alveolar cells. The patient made a full recovery after four days of in-hospital observation with supportive care.
EN
The importance of the use of waxes in the wood industry has been increasing, particularly in Europe, since consumers, due to their increased environmental awareness, avoid using biocidally treated wood and wood from tropical forests. In this research two water-repellent emulsions in various concentrations were used: polyethylene and oxidised polyethylene wax emulsion. The performance of wax treated Norway spruce (Picea abies) and beech (Fagus sylvatica) wood was tested in two sorption experiments: conditioning in high relative air humidity (vapour diffusion) and non-continuous dipping (liquid flow). The sorption properties of oven and vacuum dried impregnated specimens were determined. During conditioning, wax treated Norway spruce specimens, vacuum and oven dried, had the same moisture content as control specimens; while treated vacuum dried beech had up to 25% lower moisture content than the parallel control specimens. An even higher difference was evident in volume changes of vacuum and oven dried beech specimens during the sorption test.
PL
Znaczenie zastosowania wosków w przemyśle drzewnym rośnie, zwłaszcza w Europie, co spowodowane jest wzrostem świadomości ekologicznej, niechęcią konsumentów do używania drewna poddanego obróbce biocydami oraz drewna z lasów tropikalnych. W badaniach wykorzystano dwie emulsje wodoodporne o różnych stężeniach: polietylenową emulsję woskową i jej utlenioną wersję. Właściwości impregnowanego woskiem drewna świerka pospolitego (Picea abies) i drewna buka (Fagus sylvatica) zostały przebadane w trakcie badań sorpcji: klimatyzowania w warunkach wysokiej wilgotności względnej powietrza (dyfuzja pary) i przerywanego zanurzania (przepływ cieczy). Określono właściwości sorpcyjne impregnowanych próbek suszonych w suszarce i próżniowo. Podczas klimatyzowania próbki świerka pospolitego impregnowanego woskiem, suszone w suszarce i próżniowo, wykazały tę samą wilgotność, co próbki kontrolne. Impregnowane, wysuszone próżniowo drewno buka osiągnęło wilgotność do 25% niższą niż próbki kontrolne. Jeszcze większa różnica była widoczna w trakcie badania sorpcji w zakresie zmian objętości próbek buka suszonych w suszarce i próżniowo.
EN
The heterogeneity of both unsaturated hydraulic conductivity and water retention was measured with a high spatial resolution on a transect using an evaporation method. Fifteen undisturbed 100 cm 3 soil cores were taken on a transect every 10 cm from the topsoil of a water repellent sandy site. Five dynamic water retention curves and four unsaturated conductivity curves were determined for each core. We conducted measurements without further saturation in the laboratory in order to achieve field-like conditions. The initial water contents were hetero- geneous, indicating different hysteretic conditions and water repellent areas. The scattering of the water retention curves was high, while the heterogeneity of unsaturated conductivity curves was unexpectedly low. Two scaling approaches were used to describe the heterogeneity: one with and one without considering hysteresis. The concept of scaling applies well to describing the heterogeneity of both hydraulic functions. Including hysteresis leads to similar results than excluding hysteresis. The distribution of the hydraulic conductivity and the water retention were inde- pendent from each other. The results give important information for numerical simulation of the water flow with heterogeneous hydraulic functions.
EN
Waterproof breathable laminated fabrics have the special property that permits water vapour to pass through but protects by preventing the entrance of liquid water. Different characteristic properties of the layered constructions of these fabrics have good influence on their hydrostatic resistance and mechanical performance. This research study presents an experiment to enhance the hydrostatic resistance and tensile strength of four different types of hydrophobic membrane laminated waterproof fabrics by considering their breathability as well. For this purpose, water repellent coating based on C6-fluorocarbon resin along with polysiloxane hydrophobic softening agent was applied on these four different types of laminated fabrics using pad-dry-cure method. The coated fabrics were characterised by performing different experiments to evaluate the effect of coating on their hydrostatic resistance and mechanical property as well as on water vapour permeability and air permeability. From the test results and analysis of variance (ANOVA), it was found that hydrostatic resistance and tensile strength of the laminated fabrics were enhanced after coating along with proper water repellent property, whereas there were no significant changes in their water vapour permeability and air permeability.
6
Content available remote Znaczenie chemii budowlanej w technologii suchych mieszanek gipsowych
58%
PL
Choć proporcje dodatków i domieszek modyfikujących w recepturach nowoczesnych suchych mieszanek gipsowych nie przekraczają z reguły 1% suchej masy mieszanki, to jednak ich obecność ma znacznie poważniejszy wpływ na końcowe właściwości zapraw. Dlaczego tak się dzieje? Autor publikacji wyjaśnia logikę tej zależności.
7
58%
PL
Lekkie zaprawy (betony) sporządzone z udziałem perlitu ekspandowanego charakteryzują się podwyższoną porowatością, co skutkuje pogorszeniem niektórych właściwości użytkowych w obecności wilgoci. Praca stanowi podsumowanie badań mających na celu poprawę właściwości termoizolacyjnych tworzyw perlitowych poprzez wprowadzenie domieszek o działaniu hydrofobizującym i modyfikującym mikrostrukturę materiału. Sporządzono kilka serii zapraw cementowo-perlitowych o różnej zawartości perlitu. Scharakteryzowano ich podstawowe właściwości standardowe. Przeprowadzono pomiary podciągania kapilarnego. Dokonano obserwacji pod elektronowym mikroskopem skaningowym, podczas których potwierdzono zwartą mikrostrukturę warstwy na granicy rozdziału wypełniacz perlitowy - matryca cementowa. W badaniach kalorymetrycznych wykazano aktywny udział perlitu w procesie hydratacji. Ustalono optimum proporcji cement/perlit/domieszka, przy której relacje pomiędzy zachowaniem małej gęstości objętościowej i zmniejszeniem nasiąkliwości są najkorzystniejsze. Wskazano też na korzyści wynikające z zastosowania domieszki napowietrzającej.
EN
The lightweight cement mortars with expanded perlite reveal high porosity and, as a consequence, their insulating properties can be lowered due to the presence of environmental humidity. The studies were performed with aim to find out the mix composition of cement - perlite mortars and to optimize their parameters; first of all to reduce their density and water absorption by use of admixtures. Three series of mortars of similar consistency were produced. A water repellent and air entraining agents were used to improve the microstructure of mortars. The density and capillary suction were measured and observations of the microstructure were carried out by SEM. The transport of water in the admixtured mortars was significantly slowed and limited. The proportions, giving the lowered density at fairly low absorbability, have been pointed out. The advantageous effect of an air entraining agent has been proved too.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.