EN
The choice of control strategy of a Left Ventricle Assist Device in heart recovery is an open problem. It affects circulatory parameters, myocardial perfusion and energetic variabies, directly related to oxygen consumption in both ventricles. The experiments were performed by a computer controlled closed loop mock circulatory system, in known and constant pathological condition, connected to a pneumatic LVAD. The assistance was realized by changing artificial left ventricular systole duration and its relation to the QRS complex of ECG signal. The data were analysed as a function of haemodynamic parameters as well as energetic variabies (external work EW, oxygen consumption V0(2), cardiac mechanical efficiency CME). The results have shown: 1) assistance effect, besides driving pressure of the artificial ventricle, depends on its systole beginning and duration and on the value of peripheral resistance; 2) left heart assistance influences right ventricular parameters in limited way; it increases right atrial pressure and decreases arterial pulmonary pressure and oxygen consumption.
PL
Wybór strategii sterowania urządzenia wspomagającego LVAD dla poprawy kondycji niewydolnego serca jest problemem otwartym. Proces wspomagania oddziaływuje na parametry cyrkulacji, perfuzję mięśnia sercowego i parametry energetyczne związane bezpośrednio ze zużyciem tlenu przez obie komory serca. Opisane w niniejszej pracy eksperymenty przeprowadzono na sterowanym komputerowo fizycznym modelu układu krążenia, na którym zamodelowano stany patologiczne, poddane następnie wspomaganiu kontrpulsacyjnemu za pomocą urządzenia LVAD. W procesie wspomagania zmieniano czas trwania fazy skurczu sztucznej lewej komory urządzenia LVAD poprzez zmianę opóźnienia końca fazy skurczu tej komory względem zespołu QRS przebiegu EKG "sztucznego pacjenta". Opóźnienie początku fazy skurczu sztucznej komory pozostawało nie zmienione. Uzyskane wyniki analizowano na gruncie hemodynamicznym (ciśnienia, przepływy) i energetycznym (praca zewnętrzna EW, zużycie tlenu V0(2), współczynnik wydajności mechanicznej serca CME). Stwierdzono: 1) na efektywność wspomagania, oprócz ciśnienia sterującego pracą sztucznej komory, wpływa czas trwania jej fazy skurczu i czas opóźnienia względem zespołu QRS oraz wielkość oporności peryferyjnej; 2) wspomaganie lewej komory wywiera ograniczony wpływ na prawe serce, co się objawia niewielkim wzrostem ciśnienia w prawym przedsionku i pewnym spadkiem ciśnienia arterialnego płucnego oraz zużycia tlenu.
EN
Objectives: To assess the interaction between a continuous flow pump (CFP) and the native ventricle (NV) when both pumps are giving a flow contribution. Methods and results: The pumping system, composed of NV and of CFP, is replaced by an equivalent pump (EP) with the same NV filling characteristics and heart rate. It is assumed that EP cardiac output is equal to the sum of NV and CFP flows and that its Emax is correlated to the CFP pump speed. Both the pumping system and EP are addressed with a closed loop lumped parameters cardiovascular model connected to a Heart Mate II (HM-II) CFP. The experiments were performed to: 1: verify EP Emax correlation with CFP speed. Resulting correlation:~0.98; 2: verify EP parameters calculation accuracy, in comparison with the pumping system parameters for different values of peripheral resistance, Emax_NV, HR and CFP speed (8000–11000 RPM). Resulting average error: less than 4%; 3: show how EP can be used to obtain the desired haemodynamic or energetic conditions, then feeding the results into the pumping system, so as to regulate CFP speed accordingly. Conclusions: EP merges the properties of the pumping system composed of NVand CFP into a single pulsatile pump. The described methodology can be a useful support to optimise both haemodynamic and energetic variables in the pumping system when, with the simultaneous presence of CFP and NV flows, flow distribution between the two pumps becomes a critical issue.
EN
Circulatory models are relevant to research, education and prosthetic devices/components testing. Their structure can be both numerical and physical, according to the specific needs. Numerical models are often developed first and then followed or accompanied by physical models. This approach is associated with higher costs, less accuracy and time-consuming development. Circulatory models defined as hybrid (merger of numerical and physical sections) can solve these problems. This paper presents two applications of the hybrid model with the physical section based on two different structures (electrical and hydraulic). The results show that the model can represent hemodynamic relationships in different circulatory conditions, including IABP assistance.