Automation systems modernization in selected district heating substations in university campus buildings were described in the article. Replacement of the control valves and application of heat meters for each circuits were the scope of the renovation. Local automation systems were integrated within Building Management System. Conclusions resulted from the operation of renovated heat substations will be used in the future for further complex and optimized heating substations modernization. Analysis of the work of the heating substations in buildings built in the past few years were also presented in the paper.
PL
W artykule opisano proces rozbudowy układów automatyki w wybranych węzłach ciepła budynków uniwersyteckich. Zakres remontu obejmował wymianę zaworów regulacyjnych oraz zastosowanie liczników ciepła na poszczególnych obiegach instalacji grzewczych. Układy automatyki zintegrowano w systemie zarządzania BMS. Wnioski wynikające z eksploatacji zmodernizowanych węzłów mają w przyszłości posłużyć do dalszej, kompleksowej, zoptymalizowanej modernizacji węzłów ciepła. W artykule przedstawiono również analizę pracę węzłów obsługujących budynki wybudowane w ciągu ostatnich kilku lat.
EN
The European Union documents and national documents set out a new action program for the next 30 years, providing for comprehensive modernization of buildings, referred to as renovation. The article discusses the main findings contained in these documents and their impact on modernization projects undertaken in Poland.
|
|
tom Vol. 118, iss. 1
art. no. e2021018
EN
Renovation of multi-family residentials, including mainly thermal renovation, which includes adding thermal insulation, contributes to the improvement of living conditions. Above all, it reduces the operating costs of renovated buildings by reducing the consumption of heat energy for central heating. This article discusses the impact of light wet thermal renovation on the temperature distribution in the vertical cross-section of the partition wall and the calculation value of the temperature on the inner surface of the partition wall, as well as on the reduction of thermal energy consumption in buildings. The subject of the research was residentials erected in the large-panel, large-block, and traditional technology between 1984 and 1994, managed by Łomża Housing Cooperative (ŁSM).
PL
Konieczność oszczędności energii spowodowała zaostrzenie wymagań dotyczących izolacyjności termicznej przegród budowlanych. Spełnienie tych wymagań w przypadku zewnętrznych ścian trójwarstwowych w budynkach wielkopłytowych wiąże się z koniecznością wzmacniania połączeń warstw fakturowych z warstwami elewacyjnymi. W artykule przedstawiono nowe regulacje wprowadzone w znowelizowanej ustawie o wspieraniu termomodernizacji i remontów, dotyczących zwłaszcza budynków wielkopłytowych.
EN
The need to save energy has increased the requirements for thermal insulation of building partitions. Meeting these requirements in the case of external three-layer walls in large-panel buildings is associated with the need to strengthen the connections of the construction and facade layers. The article presents new regulations introduced in the amended Act on supporting thermo-modernization and renovation, especially regarding large-panel buildings.