Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Ograniczanie wyników
Czasopisma help
Lata help
Autorzy help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 22

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  thermal effect
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
It is a well-known problem of milling machines, that waste heat from motors, friction effects on guides, the environment and the milling process itself greatly affect positioning accuracy and thus production quality. An economic and energy-efficient method of correcting this thermo-elastic positioning error is to gather sensor data (temperatures, axis positions, etc.) from the machine tool and the process and to use that information to predict and correct the resulting tool center point displacement using regression analysis. This paper compares multilinear characteristic diagrams, B-spline characteristic diagrams, Radial Basis Function fitting and Wavelet fitting in general and also in the context of thermal error compensation. The demonstrations are made using FEM simulation data from a machine tool demonstrator. The results show that all of the above kernel types, if properly used, are able to create good compensation models. However, high-dimensional multivariate analysis usually only works by adding grid structures and regularization.
2
Content available remote Thermal effects on cathodoluminescence in forsterite
100%
EN
Cathodoluminescence (CL) spectral analysis has been conducted for luminescent forsterite (olivine) of terrestrial and meteoritic origins. Two emission bands at 3.15 and 2.99 eV in blue region can be assigned to structural defect centres and two emission bands at 1.91 and 1.74 eV in red region to impurity centres of Mn2+ and Cr3+, respectively. These emissions reduce their intensities at higher temperature, suggesting a temperature quenching phenomenon. The activation energy in the quench-ing process was estimated by a least-square fitting of the Arrhenius plots using integrated intensity of each component as follows; blue emissions at 3.15 eV: 0.08-0.10 eV and at 2.99 eV: 0.09-0.11 eV, red emissions at 1.91 eV: ~0.01 eV and at 1.74 eV: ~0.02 eV. The quenching process can be con-strued by the non-radiative transition by assuming the Mott-Seitz model. The values of activation en-ergies for blue emissions caused by structural defects correspond to the vibration energy of Si–O stretching mode in the lattice, and the values for red emissions caused by Mn and Cr impurity centres to Mg–O vibration energy. It implies that the temperature quenching energy might be transferred as a phonon to the specific lattice vibration.
EN
The compensation of thermal errors in machine tools is one of the major challenges in ensuring positioning accuracy during cutting operations. There are numerous methods for both the model-based estimation of the thermal tool center point (TCP) deflection and for controlling the thermal or thermo-elastic behavior of the machine tool. One branch of thermal error estimation uses regression models to map temperature sensors directly onto the TCP-displacement. This can, e.g., be accomplished using linear models, artificial neural networks or characteristic diagrams. One of the main limitations of these models is the poor extrapolation behavior with regard to untrained load cases. This paper presents a new method for updating characteristic diagram based compensation models by combining existing models with new measurements. This allows the optimization of the compensation for serial production load cases without the effort of computing a new model. The new method was validated on a 5-axis machining center.
EN
The electric spark induced ignition mechanism for explosives needs further study. The ignition of powdery and bulky TATB by electrostatic discharge (ESD) was investigated. Up to 200 kV ultra-high voltage ESD was applied to powdery and bulky explosives of two TATB-based polymer-bonded explosives (named PBX-1 and PBX-2). The results showed that the spark sensitivities of powdery and bulky explosives are extremely different for the same formulation. The 50% ignition voltages of powdery PBX-1 and PBX-2 were 10.8 kV and 8.5 kV, respectively, while the values for the bulky samples (tablets) were not less than 200 kV. Both heat and the electric field can be transmitted into the powdery samples, on the other hand only the electric field can be transmitted into the bulk samples. The electric field has a smaller contribution while the heat has a larger contribution to the ignition during an ESD, i.e., the thermal effect plays a main role in the ignition process. Our experimental results are in good agreement with recent results calculated by density functional theory.
PL
Celem pracy było zbadanie efektu hemodynamicznego i cieplnego terapii kompresyjnej z wykorzystaniem bandaży elastycznych. Do badań zakwalifikowano 42 osoby, które poddano działaniu terapii kompresyjnej z użyciem opasek Sigvaris o krótkim i stałym naciągu. Każdej osobie zakładano dwa bandaże na podudzie na godzinę. Oceniano, w jakim stopniu terapia kompresyjna powoduje zmianę wskaźnika kostka-ramię. Określano również zmianę prędkości przepływu krwi w tętnicy piszczelowej tylnej i grzbietowej stopy. Badano wpływ terapii kompresyjnej na efekt cieplny w obrębie podudzia. Po zakończeniu badań stwierdzono istotnie statystyczną regulację wskaźnika kostka-ramię oraz przyspieszenie przepływu krwi tętniczej. Zanotowano również znamienny efekt cieplny pod wpływem zastosowanych bandaży uciskowych. Wydaje się, że terapia kompresyjna z wykorzystaniem bandaży uciskowych prowadzi do korzystnych zmian hemodynamicznych i cieplnych, co stanowi podstawę leczenia w przypadkach przewlekłej niewydolności żylnej.
EN
The objective of this paper was to assess the haemodynamic and thermal effects of the compression therapy with elastic bandages. The 42 patients were treated with two Sigvaris bandages applied on a lower leg for 1 hour. The goal of this study was to estimate the influence of the compression therapy on the ankle - brachial index and blood flow in tibial posterior and pedis dorsal arteries. The thermal effect after compression therapy was evaluated, as well. Statistically significant regulation of ankle - brachial index and increase of arterial blood flow, were observed. The temperature increase in examined leg was stated, too. It seems that compression therapy leads to positive haemodynamic and thermal changes, beneficial for efficient treatment of chronic venous insufficiency.
EN
The aim of this research was to determine the thermobaric effect of cast composite explosives, with different masses and dimensions of the chosen explosive charges. This was done by measuring the shock wave parameters in air (maximum overpressure and pressure impulse) and quantifying the thermal effect (temperature-time dependence), at different distances from the centre of the detonation. The chosen thermobaric explosive composition, TBE-3, was characterized. Its density, detonation velocity and viscosity-time dependence were determined. Experimental samples of different masses and calibres were prepared. The shock wave parameters in air were determined in field tests, by measuring the overpressure by piezo-electric pressure transducers. The detonation and the expansion of the explosion products were filmed by a TV high-speed camera, Phantom V9. An infrared (IR) camera FLIR SC7200 was used for recording the IR scene of the explosions and for tracking the thermal effects by a thermographic technique, i.e. thermal imaging. This work is an initial step towards establishing a method for the quantification of the thermal effects of a thermobaric detonation.
7
Content available remote Termiczne efekty oddziaływania smartfonu na małżowinę uszną
75%
PL
Celem pracy było określenie zmian temperatury oraz zmian skórnych okolic małżowiny usznej związanych z używaniem telefonu komórkowego oraz ustalenie przyczyn ich powstawania. Zmierzony przyrost temperatury na powierzchni ucha po rozmowie telefonicznej jest kombinacją kilku efektów, takich jak zaburzenie konwekcji między skórą a otoczeniem, absorpcji mikrofal przez tkanki czy nagrzewania się elementów telefonu.
EN
The aim of experiment was the determination of temperature distribution and skin effects of auricle region exposed on smartphones and distinction between influence of EM waves generated by device and other factors affected temperature increase.
9
Content available remote Multi-core and single-core raspberry Pi microprocessor’s
63%
EN
A multi-core processor is defined as an integrated chip that consists of two or more processors used for system performance enhancement, speed improvement, and multitasking performances. They collaborate to execute instructions faster than the single-core processor. Hence, this paper provides an overview of the evolution of the processor architecture and analysis of the multi-core processor's performance compared to the single-core processor. It highlights the difference in Central Processing Unit speed, memory bandwidth, power consumption, and the thermal effect on the CPU speed during throttling for single-core ARM11 with Broadcom BCM2835 and a quad-core Cortex-A72 with Broadcom BCM2711B0. Experimental results show that Cortex-A72 has a memory bandwidth of 29 times larger than the ARM11. The CPU speed benchmark indicates that Cortex-A72 is significantly faster and responds to the thermal throttling better than the ARM11 processor. However, as Cortex-A72 has more processing power, it has drawn more power than the ARM11 processor.
PL
Procesor wielordzeniowy jest definiowany jako zintegrowany układ składający się z dwóch lub więcej procesorów służących do zwiększania wydajności systemu, zwiększania szybkości i wydajności pracy wielozadaniowej. Współpracują, aby wykonywać instrukcje szybciej niż procesor jednordzeniowy. Dlatego niniejszy artykuł zawiera przegląd ewolucji architektury procesora i analizę wydajności procesora wielordzeniowego w porównaniu z procesorem jednordzeniowym. Pokazuje różnicę w szybkości jednostki centralnej, przepustowości pamięci, zużyciu energii i wpływie temperatury na szybkość procesora podczas ograniczania przepustowości dla jednordzeniowego ARM11 z Broadcom BCM2835 i czterordzeniowego Cortex-A72 z Broadcom BCM2711B0. Wyniki eksperymentów pokazują, że Cortex-A72 ma przepustowość pamięci 29 razy większą niż ARM11. Test porównawczy szybkości procesora wskazuje, że Cortex-A72 jest znacznie szybszy i lepiej reaguje na dławienie termiczne niż procesor ARM11. Ponieważ jednak Cortex-A72 ma większą moc obliczeniową, pobrał więcej energii niż procesor ARM11.
PL
Przedstawiono wyniki badań efektów cieplnych towarzyszących sorpcji i desorpcji ditlenku i tlenku węgla, metanu, etanu, propanu i wodoru na węglach w zrobach ścian eksploatowanych pokładów: 510 w kopalni Wesoła, 505 w kopalni Jankowice i 405/2 w kopalni Bielszowice. Węgle z tych pokładów charakteryzują się zbliżonym stopniem uwęglenia oraz skłonnością do samozapalenia. Tego typu węgle są najczęściej eksploatowane w Polsce. Badania wykonano w temp. 308 K techniką mikrokalorymetrii przepływowej. Wykazano, że największe ilości ciepła wydzielane są podczas adsorpcji ditlenku węgla, a mniejsze podczas adsorpcji węglowodorów nasyconych (metan, etan, propan). Gazy o najmniejszym cieple adsorpcji to CO i wodór. Taką zależność uzyskano dla wszystkich badanych węgli.
EN
Bituminous coal samples of specified elementary compn., petrographic characteristics and particle size distribution collected from longwall gobs of exploited seams of 3 Polish coal mines were tested by microcalorimetry technique. The heats of adsorption and desorption of CO₂, CO, CH₄, C₂H₆, C₃H₈ and H₂ on the coal samples were detd. CO₂ showed the highest value of the heat of adsorption and CO and H₂ the lowest. Effect of coal fragmentation on gas adsorption heat was also tested. The adsorption heat increased with the increase in the amt. of larger diam. grains in the sample.
PL
Celem przeprowadzonego badania była ocena efektu cieplnego wybranych zabiegów fizykalnych stosowanych w leczeniu owrzodzeń żylnych goleni. 32 chorych z owrzodzeniami żylnymi goleni zakwalifikowano losowo do grup porównawczych 1,2 i 3. Do grupy 1. włączono 12 chorych, do 2. - 10 chorych, do 3. - 10 chorych. Wszyscy chorzy byli poddani miejscowej terapii farmakologicznej. U osób z grupy 1. wykonano zabiegi sono-terapii. Natomiast u osób z grupy 2. wykonano elektro-stymulację wysokonapięciową. U osób z grupy 3. owrzodzenia poddano biostymulacji laserowej. Oceniano, w jakim stopniu metody fizykalne wpływają na średnią i maksymalną temperaturę w obrębie ubytku. Po zakończeniu leczenia stwierdzono, że sonoterapia wywołuje istotny, choć krótkotrwały efekt cieplny. Natomiast nie zauważono efektu cieplnego w przypadku elektrostymulacji wysokonapięciowej i biostymulacji laserowej.
EN
The aim of the study was to evaluate the thermal effect of sonotherapy, high voltage electrostimulation and laser biostimulation in treatment of venous leg ulcers. Three comparative groups - 1,2 and 3 - were random-i ly chosen from 32 patients with venous leg ulcers. The I group 1 consisted of 12 patients, the group 2 of 10 pa-I tients, the group 3 of 10 patients. The patients in all comparative groups were treated pharmacologically. Ulcerations at the patients in the group 1 were additionally treated with the sonotherapy. In the group 2 high voltage electrostimulation was applied. Ulcerations at the patients in the group 3 were treated with the laser biostimulation. After therapy we concluded that ultrasound had significant thermal effect, however short. No significant effects of high voltage electrostimulation and laser biostimulation were observed.
EN
This paper investigates a three-dimensional CFD analysis of hydrodynamic journal bearing performance for two different available types of lubricants, SEA 10W50 and SEA 15W40, considering thermal, elastic deformation, and cavitation effects. A 3-dimensional CFD model founded on continuity, momentum, energy, in addition elasticity equations has been implemented. The analysis is performed for a bearing with different journal speeds (1000-3000rpm) and eccentricity ratios (0.1-0.9). The cavitation effect was considered using the model of Zwart-Gerber-Balamri multiphase flow model. The bearing material elastic deformation was considered by implementing the two-way FSI technique through ANSYS-FLUENT 2019 R2. A comparative study of the oil film temperature, thermal pressure, also the load capacity by the bearing has been performed. By comparing the current work's oil film temperature results with those obtained by Ferron et al (1983), with a maximum deviation between the results not exceeding 3 percent, the mathematical model was validated. The findings demonstrate that, once the cavitation consequence is taken into account, the lubricant film pressure decreases. Furthermore, at what time the bearing rotates at greater eccentricity ratios and rotational speeds, more deformation material of the bearing is seen. The current research may help in predicting the bearing performance parameters in real-world situations.
16
63%
|
|
tom Vol. 31, no. 1
73--89
EN
According to the results of the laboratory and analytical studies and research-and-industrial operations, it is established the efficiency of complex use of thermal methods, hydrocarbon solvents and surfactants for the effect on high-viscosity oil and it is suggested the technology for high-viscosity oil wells stimulation.
PL
W pracy przedstawiono wyniki obliczeń numerycznych i badań eksperymentalnych efektu cieplnego odkształcenia plastycznego podczas procesu kucia promieniowego prętów ze stopu cyrkonu Zr-Nb W zakresie temperatur 20÷500 °C i przy prędkości odkształcenia 0,5 i 15 s-1.
EN
This paper presents results of mathematical modelling and physical research of thermal effect during radial forging of zirconium alloy rods at temperature under interval 20÷500 °C during strain rate 0,5 and 15 s-1.
EN
Three groups of carps were kept for 6 to 12 weeks at 11°C, 16°C and 23°C. A portion of the fish from each group was infected with Aeromonas hydrophila. Experimental fish were subjected to evaluation of number of thrombocytes, the index of bacteria-thrombocyte adherence (IB-TA), the percentage of active thrombocytes (%AT) and the index of thrombocyte aggregation (ITA). Carps kept at 11℃ revealed the highest values of the indices examined whereas carps kept at 23℃ the lowest ones. The indices were examined singly bcfore the bacteria administration. Fish demonstrating the lowest values of the indices were most sensitive to the infection and revealed the highest mortality rate. In contrast, fish with the highest values of the indices revealed the highest immunity. These relationships were obvious mainly at 11°C whereas at 23°C, by contrast, they were less distinct.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.