In majority of factories like cement mills, electric motors working there are subject to a considerable influence of weather conditions due to their location. A significant number of those machines are placed in the open air, and in some mills, in the period of increased air humidity, from November to March, the factory delays production and the planned repairs of production lines are implemented. In this period diagnostic tests of electrical machines are also carried out. Some of the tested motors have built-in heating systems what limits the soaking of the windings insulation, whereas others have no such heating systems and that is reflected in the received results. The article presents a short history (2001-2007) of conducting diagnostic tests of insulation of medium voltage electric motors with the DC voltage method. The results of the tests and their influence on limiting repairs as well as tendencies of changes in motors working in fairly difficult exploiting conditions are presented.
Inverter Driven Motors (IDM) with high speed switching and advanced Pulse Width Modulation (PWM) techniques have been widely used for variable speed applications. Adjustable Speed Drives (ASD) with high speed switching devices provide very accurate control of speed and torque to a system. However, ASD give electrical stress such as high peak voltage, fast rate of voltage change (dV/dt) and extremely high carrier frequency to the insulation materials of a motor. The degradation of electrical insulation used in Inverter Driven Motors can lead to premature failure of motors sometimes days or months after startup. This paper presents the evaluation process of insulating materials used for IDM. Thermal aging tests were carried out on motorettes with enameled wires, impregnating resin and different insulating materials. Partial Discharge Inception Voltage (PDIV) measurement and Diagnosis test, based on IEC 60034-18-41 TS, were conducted on the motorettes. It could be demonstrated that the PDIV of the motorette decreased during aging and was very much dependent on the types of insulating materials being used.
Przedstawiono wyniki badań drzewienia elektrycznego w początkowej fazie rozwoju w izolacji z polietylenu usieciowanego. Badania przeprowadzono w układzie ostrze -płyta uziemiona, przy udarach łączeniowych nałożonych na napięcie przemienne. Przyspieszenie procesu degradacji izolacji udarami obserwowano tylko dla składowej przemiennej porównywalnej lub mniejszej od napięcia progowego. Rozwój wyładowania drzewiastego śledzono metodą mikroskopową z rejestracją cyfrową powstających obrazów.
4
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule przedstawiono wybrane problemy związane z procesem starzeniowym izolacji polietylenowej w elektroenergetycznych liniach kablowych średniego napięcia wynikającą ze zjawisk elektrycznych występujących w czasie eksploatacji sieci. Przedstawiono podstawowe czynniki odpowiedzialne za starzenie układu izolacyjnego kabli średniego napięcia.
EN
The article presents selected problems related to ageing of polyethylene insulation in medium voltage cable power lines resulting from electrical phenomena occurring during network operation. Basic factors responsible for the ageing processes of the medium voltage cable insulation system are presented.
The diagnostics of insulating system of electric machines under pulse stress is at the present one of the most focused fields. The converters produce repetitive pulses with the high level of voltage rise fronts (slew rates). Rise fronts attain values of up to the tens of kilovolts per microsecond and voltage pulse repetition frequency up to some tens of kilohertz. However, this technology is an advantage for a drive control; the voltage waveforms generated by power frequency converters may significantly affect the reliability of the electric motor insulation systems. To improve understanding of the processes in the electrical insulation materials during the pulse voltage aging, it is necessary to monitor values of the electric parameters within a pulse stress aging process. For the studying of the main-wall insulation material pulse voltage aging processes there were chosen these electrical parameters: the dissipation factor, capacity, absorption and resorption currents, corona inception voltage (CIV) and partial discharges (PD) activity level. These parameters are easily detectable and their development characteristics are very well known in the terms of sinusoidal voltage aging process. This paper presents experimentally measured data of the observed electric parameters during the pulse and sinus voltage aging. The difference between the sinusoidal voltage aging and pulse voltage aging time dependencies is shown as well observable in this paper as well.
PL
Diagnostyka układu izolacji maszyn elektrycznych metodą impulsową nabiera coraz większego znaczenia. Przemienniki wytwarzają powtarzające się impulsy o wielkiej stromości narastania napięcia osiągające wartość kilkudziesięciu kilowoltów na mikrosekundę i częstotliwość dziesiątków kiloherców. I choć technologia ta ma wyraźne zalety dla regulacji prędkości obrotowej napędów, fale napięciowe generowane przez przemienniki mogą znacząco wpływać na trwałość układu izolacyjnego maszyny. Dla poprawy zrozumienia procesów starzeniowych układu izolacyjnego zachodzących w trakcie impulsów napięciowych koniecznym jest monitorowanie wartości elektrycznych występujących w czasie trwania impulsu. Dla analizowania starzenia izolacji głównej wybrano takie parametry jak: współczynnik rozproszenia, pojemność, prąd absorpcji i resorbcji, napięcie początkowe korony, i poziom wyładowań niezupełnych. Te parametry są łatwe do pomiaru a ich przebiegi są dobrze znane dla procesów starzeniowych od napięcia sinusoidalnego. W artykule przedstawiono zależności czasu starzenia układu izolacji skutkiem działania napięcia sinusoidalnego i starzenia izolacji od impulsów napięciowych.
6
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
In this paper the impact of harmonic distortion on the life span and functional reliability indices of power transformers, induction motors and cables is considered. The detrimental effects of harmonics on equipment are analyzed using both deterministic and probabilistic approach.
PL
W artykule analizowano wpływ zniekształceń harmonicznych na poprawność działania transformatorów energetycznych, silników indukcyjnych kabli. Efekty szkodliwe były analizowane z uwzględnieniem deterministycznych i przypadkowych teorii. Zaproponowano wprowadzenie wyrażenia na współczynnik obniżenia wartości znamionowych uwzględniający możliwość wcześniejszego uszkodzenia urządzeń na skutek pracy przy odkształconym zasilaniu. Na zakończenie przedstawiono przykłady numeryczne ilustrujące najbardziej typowe sytuacje.
W artykule zaprezentowano krótką historię (2001-2006) prowadzenia badań diagnostycznych izolacji silników elektrycznych średniego napięcia metodą napięcia stałego. Przedstawiono wyniki badań i ich wpływ na ograniczenie remontów; tendencje zmian w silnikach pracujących w dość trudnych warunkach eksploatacji.
EN
The article presents the short history (2001-2006) of carrying out diagnostic testing of insulation of middle voltage electric motors with utilizing constant voltage method. The paper presents the results of these diagnostic testing, and its influence on reduction of overhauls. There are showed trends in changes in electric motors, which are operating in hard working conditions.
8
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Przedstawiono ideę modelu probabilistycznego do oceny żywotności linii kablowych uwzględniającego procesy starzeniowe zachodzące w jej elementach składowych pod wpływem pola elektrycznego, oddziaływania mechanicznego i czynnika losowego oraz sposób jego zastosowania do linii kablowych WN u jednego z krajowych zarządców sieci elektroenergetycznej.
EN
The idea of probabilistic modeling of the lifetime of HV power cables, including aging phenomena caused by electrical, mechanical and random stress is given and applied to the cable system managed by one of domestic electrical energy utility.