Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Ograniczanie wyników
Czasopisma help
Lata help
Autorzy help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 78

Liczba wyników na stronie
first rewind previous Strona / 4 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  stężenie
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 4 next fast forward last
PL
W pracy omówiono wyniki pomiarów stężenia amoniaku w powietrzu wentylowanym z sześciu tuczarni trzody chlewnej. Tuczarnie te reprezentują najczęściej stosowane w Polsce i w Europie systemy utrzymania świń. Określono typy tuczarni, które powinny być wyeliminowane z praktyki rolniczej.
EN
The results of measurements of ammonia concentration in the air in six building for fatteners are discussed. The piggeries are reperesentative for the most frequently pig keeping systems used in Poland and Europe. It is pointed out which types of building should be eliminated from the every day use.
|
|
tom R. 6, nr 2
80-87
PL
Przedstawiono analizę zróżnicowania stężenia ołowiu na obszarze byłego woj. katowickiego. Podstawą do rozważania były wyniki pomiarów prowadzone przez stacje sanitarno-epidemiologiczne woj. katowickiego w latach 1976-2000. Na ich podstawie stwierdzono znaczny i systematyczny spadek stężenia ołowiu na całym badanym obszarze do poziomu obowiązujących norm.
EN
The article presents analysis of lead concentration variability in the area of the former Katowice Voievodeship. Data from measurements carried out by the sanitary and epidemiological stations in the area of the former Katowice Voievodeship in the years 1976-2000 served as input data for the analysis. Based on this data a considerable and systematic drop of lead concentration to the level of effective standards in the entire area of the study has been stated.
4
Content available remote Konieczność kontrolowania stężeń rtęci w środowisku
75%
5
Content available remote Obliczanie stężeń hal stalowych według PN-EN 1993-1-3
75%
|
|
tom nr 1
34-37
7
Content available remote Pomiary stężenia dwutlenku węgla w sypialniach domku jednorodzinnego
75%
PL
Podano wyniki pomiarów stężenia dwutlenku węgla w sypialni domu jednorodzinnego sypialni. Pomiary prowadzone były przed i po spaniu nocnym oraz przed i po spaniu dziennym. Źródłem dwutlenku węgla w badanych pomieszczeniach byli tylko ludzie: matka z 9 miesięczną córką w sypialni 1 oraz ojciec z 2,5 letnim synem w sypialni 2.
EN
Measurement results of carbon dioxide concentration in a sleeping room in a single-family house are given. The measurements were carried out before and after a night' sleep and before and after a day's sleep. The carbon dioxide sources were only a mother with her daughter in one sleeping room and a father with his son in the other.
8
Content available remote Zmiany zawartości WWA w ściekach podczas ich oczyszczania
75%
PL
Celem badań było przeanalizowanie zmian stężeń wielopierścieniowych węglowodorów aromatycznych (WWA) w ściekach miejskich podczas poszczególnych procesów ich oczyszczania. Badane ścieki były mieszaniną ścieków bytowo-gospodarczych (70%) i przemysłowych (30%). Procesy oczyszczania obejmowały: sedymentację zawiesin mineralnych i zawiesin łatwo opadających oraz usuwanie związków węgla i azotu realizowane w reaktorach z wydzielonymi strefami beztlenową i tlenową oraz sedymentację wtórną. Zakres pracy obejmował pobór ścieków z 5 punktów pomiarowych. Pobierano średniodobowe próby zgodnie z harmonogramem uwzględniającym czas zatrzymania ścieków w poszczególnych urządzeniach. Przygotowanie prób do oznaczania jakościowo-ilościowego WWA polegało na ekstrakcji materiału organicznego po dodaniu metanolu, cykloheksanu i dichlorometanu, następnie oczyszczaniu prób na żelu krzemionkowym i ich zatężaniu w strumieniu azotu. Analizowano zawartość 16 zalecanych przez EPA WWA metodą chromatografii gazowej ze spektrometrem masowym GC-MS. Otrzymane wyniki badań pozwoliły na określenie skuteczności usuwania WWA ze ścieków w trakcie ich oczyszczania. Podczas sedymentacji wstępnej ścieków realizowanej w płaskownikach i w osadnikach wstępnych uzyskano 45% ubytek ilości oznaczalnych WWA. Oczyszczanie biologiczne natomiast wraz z sedymentacją wtórną pozwoliło na dalsze usunięcie 70% ilości oznaczalnych WWA pozostałych po mechanicznym oczyszczaniu. Jednocześnie odnotowano spadek zawartości oznaczalnych WWA podczas całego procesu oczyszczania z wartości 5,164 do 0,780 žg/dm3, a więc o 85%. Ubytek zawartości WWA w ściekach należy głównie wiązać z sorpcją tych związków na cząstkach stałych, gdyż jednocześnie odnotowano wysokie ich zawartości w osadach wydzielanych ze ścieków.
EN
The subject of this paper is the change of polycyclic aromatic hydrocarbons (PAHs) concentration during the municipal wastewater treatment processes. A mixture of municipal (70%) and industrial (30%) wastewaters was studied. The treatment processes included: sedimentation of mineral and easily settleable solids, removal of carbon and nitrogen compounds in anoxicoxic bio-reactors with secondary sedimentation. Daily average samples were taken at 5 sampling points, with a time delay including retention times in each treatment process. PAHs were extracted from the wastewaters with methanol, cyclohexane and dichloromethane, cleaned-up using silica gel and then concentrated in the nitrogen stream. Sixteen PAHs listed by EPA were analysed by GC-MS. Efficiencies of PAHs removal in each treatment process were established. Primary sedimentation in grit chambers and settlers resulted in 45% removal. Biological treatment with secondary sedimentation decreased PAHs concentration remaining after mechanical treatment by 70%. In the whole system PAHs concentration was lowered from 5.164 žg/dm3 to 0.780 n žg/dm3, that corresponds 85% of total removal. The decrease of PAHs concentration seems to be mainly caused by sorption of these compounds on solid parts as at the same time high PAHs concentrations in waste sludge were found. Concentration of benzo(a)pyrene (B(a)P) in the treated wastewater did not exceed 0.1 žg/dm3, whereas the permissible value equals 2 žg/dm3. Concentrations of 5- and 6-ring polycyclic aromatic hydrocarbons were at the similar level in the raw and treated wastewater. However, the noticeable decrease of those PAHs contents after mechanical treatment process was observed.
|
2005
|
tom Nr 6
246-251
PL
Przedstawiono wyniki badań wody pochodzącej ze stawów parkowych zlokalizowanych na terenie Wrocławia. Analizie poddano układ termiczno-tlenowy charakteryzujący badane obiekty oraz omówiono dynamikę zmian wybranych wskaźników chemicznych określających jakość w tych zbiornikach. Szczególną uwagę zwrócono na zawartość substancji biogennych, tlenu rozpuszczonego oraz wartości BZT_, i ChZT. Badania wody prowadzono od marca do listopada 2003 r. Wyniki analiz wykazały niską jakość wód pochodzących z tych stawów.
EN
In the presented work there are shown results of investigation of water originated from situated in Wroofaw reservoirs. The results of investigation which comprised the thermal and oxygenic conditions existing in the reservoirs and the dynamics of changes of selected chemical indicators of water quality in the ponds in Wroclaw have been analysed and described. Particular attention has been paid to the content of biogenic substances, dissolved oxygen and the values of COD and BOD5. The investigations were carried out in the period from March to November 2003. The results of chemical analyses testify to the low state of water quality in the Wroclaw ponds.
EN
Carbon dioxide is the fourth component in terms of the concentration in the air. The high concentration of CO2 influences people in the negative way. Heat gains, air humidity and the concentrations of the airborne pollutants are taken into consideration during ventilation system designing process. In the indoor pollution balances the amount of the air, which is needed to remove the excess of the carbon dioxide is much lower than one in the case of the excess of the heat. The measurements of CO2 concentration, humidity and temperature in the cinema projection room are presented in the work. The results are analyzed in relation to the acceptable indoor air quality, because the cinema auditorium is assumed to be an average indoor space.
EN
Low concentration of carbon dioxide in the atmospheric air is considered to be a normal condition. Excessive concentration of CO2 in the air may have negative influence on human’s health. Permissible level of carbon dioxide concentration in didactic facilities as well as in all other closed spaces is 1000 ppm (WHO, 2000a), as devised by the WHO Regional Office for Europe. Two varieties of measurements were taken. 1. The level of CO2 concentration was examined in classrooms in which different types of ventilation systems are used. 2. The efficiency of the ventilation system was measured on the basis of the parameters of the inside air; particular attention was paid to the level of CO2 concentration.
EN
Motor vehicles release into the air NOx, which is 50-70% of all pollutants in the atmosphere of larger cities. Both car traffic and solar radiation vary in time and consequently variation of NOx concentration occur in diumal cycle and annual cycle. The paper presents introductory results of the analysis on distribution and the relationship between oxides of nitrogen concentration and the air temperature and air humidity. Average value of considered pollutants concentration for the period since 1.IV.2001 to 31.III.2002 in Ursynów-WAU assumes 15,9 μgm m-3 (40% of permissible concentration) for NO2 and for NO 5,2 μgm m-3.
EN
Purpose: This article aims to investigate the impact of polymer type and concentration in the fracturing fluid on the size and permeability of fractures during hydraulic fracturing. The aim is to predict the conductivity and productivity of the formed fractures in order to evaluate the cumulative gas production. Design/methodology/approach: The influence of polymer concentration in the fracturing fluid on the size and permeability of fractures was studied using the GOHFER software from Haliburton. Findings: The results of the study show that by combining the effect of increasing fracture size and decreasing the permeability of the proppant, a gas flow rate increase of 3.5 times was achieved. Research limitations/implications: High polymer concentrations lead to reduced permeability due to the accumulation of polymer residues and polymer skin. Practical implications: The conducted study on the impact of polymer concentration in the fracturing fluid on the size and permeability of fractures will allow for a more qualitative hydraulic fracturing process. Originality/value: This article presents how the concentration and type of polymer affect the width, thickness, length, and conductivity of fractures during hydraulic fracturing.
|
2013
|
tom R. 69, nr 6
334--337
PL
Omówiono ogólne zasady obliczeń poprzecznych stężeń dźwigarów dachowych oraz stężeń pionowych międzysłupowych zawarte w normie PN-EN 1995-1-1 (Eurokod 5). Podano przykłady obliczania oddziaływań imperfekcyjnych na te systemy stężające oraz zasady i przykłady ich rozmieszczania.
EN
General principles of calculation of the roof transversal bracings and vertical bracing for a series of columns according to PN-EN 1995-1-1 (Eurocode 5) have been presented. Examples of calculating the internal stability load per unit length of the bracing systems, main rules and also examples where multiple bracing systems for a series of compression or bending members are required were given in this paper.
16
Content available Issues of radon (Rn-222) exhalation measurements
63%
EN
The Rn-222 isotope, a naturally occurring radioactive gas, is created in a radioactive decay of Ra-226. Both radionuclides belong to the radium decay chain in which U-238 is the prime parent. Radon is usually in plenty found in the earth crust, rocks, soil, water and air, therefore it is regarded as an indicator of ionizing radiation dose received by a population. Due to radon negative influence on people’s health, measurements of its concentration are commonly performed. The presented research concerns assessment of measurements uncertainty of Rn-222 concentration exhaled from soil. The measurements were repeated at the same site. The experiment was carried out in natural conditions, in the city center and lasted about half a year. In Rn-222 concentration measurements the AlphaGUARD radon monitor was used. The device was operating in the 10-minutes flow mode, with the air pump and exhalation-box arranged in the closed cycle. The studies have shown a significant differences between results of radon exhalation measurements, which were carried out sequentially in the same place. Generally, increase in measurements number in a series lowers the result uncertainty. Consequently, the number of measurements in a series can be adjusted to the desired uncertainty of result. What is more, the distribution of the results in series is well described by the Poisson distribution.
PL
Izotop Rn-222, naturalnie występujący radioaktywny gaz, powstaje na skutek rozpadu promieniotwórczego Ra-226. Oba radionuklidy należą do szeregu uranowo-radowego, który rozpoczyna U-238. Radon występuje w dużych ilościach w skorupie ziemskiej, skałach, glebie, wodzie i powietrzu, dlatego jest on traktowany jako wskaźnik dawki promieniowania jonizującego otrzymywanego przez ludzi. Ze względu na negatywny wpływ radonu na zdrowie ludzi pomiary stężenia tego gazu są często wykonywane. Zaprezentowano wyniki badań niepewności pomiarowej stężenia Rn-222 w powietrzu ekshalowanym z gleby. Pomiary powtarzano wielokrotnie w tym samym miejscu. Eksperyment przeprowadzony został w warunkach naturalnych, w centrum miasta i obejmował okres około pół roku. Do pomiarów stężenia radonu wykorzystano monitor radonowy AlphaGUARD. Pracował on w 10-minutowym trybie przepływowym, z pompą oraz komorą ekshalacyjną w obiegu zamkniętym. Badania wykazały znaczne różnice pomiędzy wynikami pomiarów, wykonywanych w całym okresie badawczym. W pojedynczej serii większa liczba pomiarów zmniejsza niepewność pomiarową. Dzięki temu ilość pomiarów w serii może być dostosowana do oczekiwanej niepewności pomiarowej wyniku. Stwierdzono, że rozkład wyników aktywności radonu w serii jest dobrze opisywany przez rozkład Poissona.
PL
Dioksyny są grupą chloroorganicznych związków toksycznych dla ludzi. Do grupy tej zaliczamy siedem kongenerów polichlorowanych dibenzo-p-dioksyn (PCDD), dziesięć polichlorowanych dibenzofuranów (PCDF) oraz dwanaście dioksynopodobnych polichlorowanych bifenyli (dl-PCB). Głównym źródłem narażenia dla człowieka jest żywność pochodzenia zwierzęcego (ponad 80%). Ponieważ ryby stanowią część naszej diety, ze względu na bezpieczeństwo i zdrowie konsumentów wiedza o stopniu ich zanieczyszczenia jest bardzo ważna. W Europie prowadzono wiele badań nad zanieczyszczeniem dioksynami i PCB ryb pochodzących z różnych rzek i akwenów. Brak informacji o poziomie stężeń tych związków w rybach pochodzących z polskich wód śródlądowych stał się jedną z przyczyn podjęcia projektu badawczego, którego celem jest określenie poziomów dwudziestu dziewięciu kongenerów dioksyn i PCB w tkance mięśniowej ryb wolno żyjących. Badaniu poddano 48 próbek: leszcza (Abramis brama), sandacza (Sander lucioperca), szczupaka (Esox lucius), bolenia (Aspius aspius), płoci (Rutilus rutilus), okonia (Perca fluviatilis), złowionych w pięciu rzekach i jeziorach w Polsce: rzekach Wkrze (Żuromin), Brdzie (Człuchów), Wiśle (Nowy Dwór Mazowiecki i Kraków), Zbiorniku Rybnickim (Rybnik) oraz Jeziorze Łańskim (Olsztyn). Analizy chemiczne wykonano metodą rozcieńczeń izotopowych przy użyciu zestawu chromatografu gazowego z wysokorozdzielczym spektrometrem mas (HRGC-HRMS). W badanych próbkach tkanek ryb nie stwierdzono obecności dioksyn w stężeniach przekraczających dopuszczalne limity, które dla ryb zgodnie z rozporządzeniem Komisji Europejskiej (WE) nr 1881/2006 z dnia 19 grudnia 2006 r. wynoszą odpowiednio 4 pg WHO-TEQ dla PCDD/PCDF i 8 pg WHO-TEQ dla PCDD/PCDF i dl-PCB na gram świeżej masy (ś.m.). W wodach uznanych za ekologicznie czyste, tj. Brda, Wkra, Jezioro Łańskie, stężenia oznaczonych związków występowały na bardzo niskim poziomie, na granicy oznaczalności metody, która wynosi 0,13 pg WHO-TEQ/g ś.m. dla dioksyn i furanów, a dla sumy 29 kongenerów 0,33 pg WHO-TEQ/g ś.m. W wodach potencjalnie zanieczyszczonych (rzeka Wisła i Zbiornik Rybnicki) stężenia badanych związków były podwyższone w różnym stopniu w stosunku do wód czystych i w zależności od miejsca pobrania ryb przeważały PCDD, PCDF (Zbiornik Rybnicki) lub dl-PCB (rzeka Wisła). W rybach z Wisły złowionych w okolicach Krakowa, które zawierały najwyższe stężenia badanych związków, stwierdzono dl-PCB w stężeniach od 1,06 ± 0,18 do 2,86 ± 0,48 pg WHO-TEQ/g ś.m. Suma wszystkich kongenerów znajdowała się w zakresie od 1,33 ± 0,22 do 3,49 ± 0,58 pg WHO-TEQ/g ś.m. Podwyższone stężenia dioksyn w tkankach ryb złowionych w Wiśle na wysokości Krakowa, Nowego Dworu Mazowieckiego oraz ze Zbiornika Rybnickiego wskazują na skażenie środowiska wodnego dioksynami i PCB, w którym bytują ryby, oraz na istnienie źródeł tych związków chemicznych w pobliżu miejsc ich pobrania. Badania wykonano w ramach projektu badawczo-rozwojowego NCBR nr 12-0127-10/2010.
EN
Dioxins are a group of organochlorine compounds which are toxic to humans. This group includes seven congeners polychlorinated dibenzo-p-dioxins (PCDD), ten polychlorinated dibenzofurans (PCDF), and twelve dioxin-like polychlorinated biphenyls (dl-PCB). The main source of exposure for humans is the food of animal origin (over 80%). Because fish are part of our diet, due to the safety and health of consumers, knowledge about their degree of pollution is very important. In Europe had many studies on pollution of dioxin and PCBs in fish from different rivers and water reservoirs. The lack of information on the level of concentrations of these compounds in fish originating from the Polish inland waters became one of the reasons for a research project, whose purpose is to define the levels of twenty nine congeners dioxins and PCBs in muscle of free-living fish. Forty nine samples of bream (Abramis brama), zander (Sander lucioperca), pike (Esox lucius), asp (Aspius Aspius), roach (Rutilus rutilus), perch (Perca fluviatilis) caught in Polish five rivers and reservoirs: the river Wkra (Zuromin), Brda (Czluchow), Vistula (Nowy Dwor Mazowiecki, and Cracow ), Rybnik Reservoir (Rybnik) and Lansk Lake (Olsztyn) were tested. Chemical analyzes were made using isotope dilution technique with high-resolution gas chromatograph and mass spectrometry detection (HRGC-HRMS). The results have showed there were no samples exceeding the maximum limits, which for the fish in accordance with Commission Regulation (EC) No. 1881/2006 of 19 December 2006 are set to 4 pg WHO-TEQ for PCDD/F and 8 pg WHO-TEQ for PCDD/F and dl-PCB per gram of fresh weight (f.w.). In waters classified as a clean: Brda, Wkra, Lanskie Lake, concentrations of compounds were very low, and were at the limit of quantification of the method, which is 0.13 pg WHO-TEQ/g f.w. for dioxins and furans and for the sum of 29 congeners 0.33 pg WHO-TEQ/g f.w. Potentially contaminated waters (the Vistula River and Rybnik Reservoir) concentrations of tested compounds were increased in varying degrees to the clean waters and depending on the place of collection of fish. PCDDs, PCDFs (Rybnik Reservoir) or dl-PCBs (Vistula River) were dominating compounds. The fish from the Vistula River the vicinity of Cracow, which contained the highest concentrations of tested compounds, dl-PCBs were found at concentrations of 1.06 ± 0.18 to 2.86 ± 0.48 pg WHO-TEQ/g f.w. The sum of all dioxin and dl-PCB congeners were in the range from 1.33 ± 0.22 to 3.49 ± 0.58 pg WHO-TEQ/g f.w. The elevated concentrations of dioxins in fish tissues from Vistula in Cracow and Nowy Dwor Mazowiecki vicinity as well as Rybnik Reservoir indicate contamination of the aquatic environment by dioxins and PCBs, and the existence of sources of these chemicals in the vicinity of fish collection.
PL
Dokonano pomiarów przewodnictwa zawiesiny mineralnej w trakcie jej sedymentacji na różnych poziomach kolumny sedymentacyjnej. Obliczono profile stężeń ciała stałego w trakcie sedymentacji. Wyniki sedymentacyjne skorelowano z pomiarami potencjału dzeta.
EN
The electrical conductivity measurements of mineral suspensions under the different condition have been done. The concentration profiles during the sedimentation were calculated. The conductivity results were compared to the zeta potential of mineral particles.
PL
Wzrost natężenia ruchu samochodowego, a tym samym wzrost emisji zanieczyszczeń do atmosfery powoduje istotną zmianę jakości powietrza w obrębie drogowych węzłów komunikacyjnych, szczególnie o dużym natężeniu ruch samochodowego. Na podstawie badań przeprowadzonych w wybranych drogowych węzłach komunikacyjnych Opola wykazano, iż na obszarach tych występuje zjawisko pojawiania się okresowego niedoboru tlenu w powietrzu. Te okresowe niedobory ilości tlenu oraz wzrostu stężenia tlenków azotu w powietrzu występują, nie tylko na obszarze rond komunikacyjnych, ale co jest także istotne wzdłuż ulic stykających się z danym rondem drogowym. Poziom ubytku tlenu w powietrzu jest znaczy i bardzo szybki wraz ze wzrostem natężenia ruchu drogowego. Wynosi on od 0,2 do 1,2%, a w skrajnym wypadku dochodziła nawet do 2,8% objętości.
EN
The growth of intensity of car movement causes on area of and roads of the communication crossings the quality change. The results of testing of influence intensity movement vehicles in running were introduced on level the concentration in air the oxygen and oxides of nitrogen on of the communication routes. It the formation in air the deficit of oxygen was showed was both on area of road roundabout, as and along streets. The study was conducted on chosen crossings and along roads of city of Opole. The level of decrease of oxygen in air is considerable and very the quick together with growth of traffic density. The decrease of oxygen in air the carried out from 0,2 to 1,2 %, and level 2,8% in extreme case achieved volume.
20
Content available remote Badania stężenia dwutlenku węgla w sali dydaktycznej
63%
PL
Niewielkie stężenie dwutlenku węgla w powietrzu jest naturalnym stanem powietrza. Zbyt duże jego stężenie w powietrzu może mieć negatywne skutki dla zdrowia. Dopuszczalne stężenie dwutlenku węgla zalecane przez europejski oddział Światowej Organizacji Zdrowia (WHO) w salach dydaktycznych (jak i we wszystkich pomieszczeniach o przeznaczeniu ogólnym) wynosi 1000 ppm.
EN
A small concentration of carbon dioxide in the air is the natural state of the atmosphere. Too large concentration may have negative effects on health. The permissible concentration of carbon dioxide, recommended by the European branch of the World Health Organization (WHO) in the classrooms (as well as in all areas of general-purpose), amounts to 1000 ppm . A small concentration of carbon dioxide in the air is the natural state of the atmosphere. Too large concentration may have negative effects on health. The permissible concentration of carbon dioxide, recommended by the European branch of the World Health Organization (WHO) in the classrooms (as well as in all areas of general-purpose), amounts to 1000 ppm.
first rewind previous Strona / 4 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.