2013
|
tom Vol. 34, no. 3
173--184
EN
High heat flux removal are important issue in many perspective applications such as computer chips, laser diode arrays, or boilers working on supercritical parameters. Electronic microchips constructed nowadays are model example of high heat flux removal, where the cooling system have to maintain the temperature below 358 K and take heat flux up to 300 W/cm2. One of the most efficient methods of microchips cooling turns out to be the spray cooling method. Review of installations has been accomplished for removal at high heat flux with liquid sprays. In the article are shown high flux removal characteristic and dependences, boiling critical parameters, as also the numerical method of spray cooling analysis.
PL
W pracy zaprezentowano wyniki pomiarów intensywności chłodzenia dla wybranej dyszy wodno-powietrznej. Na podstawie otrzymanych wyników sporządzono mapę rozkładu współczynnika wnikania ciepła dla trzech różnych temperatur początku chłodzenia. Badania wykonano dla dwóch odległości dyszy rozpylającej mieszaninę wodno – powietrzną od chłodzonego materiału.
EN
The paper presents the results of measurements of the intensity of cooling for the selected water-air nozzle. On the basis of the results map of the distribution of heat transfer coefficient for the three temperature settings beginning of the cooling was drawn. Testes were performed for two distances of the spray nozzle within the mixture of water - air in respect to the cooling material.
PL
W pracy przedstawiono budowę stanowiska badawczego, metodykę pomiarów i obliczeń oraz wstępne wyniki badań doświadczalnych chłodzenia podgrzewanej powierzchni strugami wody. Celem pracy jest wstępna analiza wpływu procesu odsysania mieszaniny parowo-powietrznej na intensywność procesu odparowania filmu wodnego. Nagrzana powierzchnia chłodzona jest trzema strugami wody wytwarzanymi w zakraplaczach zamontowanych w płytce i ustawionych w wierzchołkach trójkąta równobocznego. Natężenie przepływu wody jest ustalone. W środku tego trójkąta umieszczono sondę połączoną z pompą próżniową, zadaniem której jest usunięcie powstałej nad powierzchnią filmu pary wodnej i otaczającego układ powietrza atmosferycznego. Strugi wody chłodzą powierzchnię roboczą grzejnika wykonanego z bloku miedzianego o wymiarach 0,04×0,04×0,02 m. Eksperyment przeprowadzono dla temperatury podgrzewanej powierzchni zmieniającej się w zakresie od 50÷100°C. Na podstawie analizy uzyskanych wstępnych wyników badań oszacowano, że odsysanie mieszaniny parowo-powietrznej z nad warstwy filmu cieczowego zwiększa się intensywność odparowania chłodziwa (wody) o około 25÷50%.
EN
The paper presents test stand structure, measurement and calculation methodology and initial results of investigation of preheated surface cooling by water stream The aim of this article is preliminary analysis of influence of steam-air mixture evacuation on the intensity of water film evaporation. The hot surface is cooling by three streams of water. Streams are produced in droppers mounted in plate and located in the vertices of a equilateral triangle. The water flow rate is stationary. In the center of triangle is mounted the probe connected to a vacuum pump that is used for evacuation of steam-air mixture from above the hot surface and atmospheric air surrounding the system. Streams of water cooling the heater surface made of cooper block with the dimensions: 0.04×0.04×0.02 m). The surface temperature of block is changed in the range from 50°C to 100°C. Based on the results of preliminary investigations itwas stated that the suction of steam-air mixture from above the liquid film layer enhancement the water film evaporation about 25÷50%.
PL
W pracy przedstawiono budowę stanowiska badawczego, metodykę pomiarów i obliczeń oraz wstępne wyniki badań doświadczalnych procesu chłodzenia podgrzewanej powierzchni strumieniem kropel wody, gdy powstająca mieszanina parowo-powietrzna jest odsysana z zamkniętej przestrzeni otaczającej grzejnik. Badania przeprowadzono dla trzech wariantów procesu chłodzenia grzejnika tj. przy zastosowaniu bocznego odsysania powstającej mieszaniny przestrzeni nad ogrzewaną powierzchnią, przy odsysaniu tej mieszaniny z wnętrza tej przestrzeni oraz w warunkach, gdy mieszanina powietrzno-parowa nie jest odsysana. Celem pracy jest analiza wpływu miejsca odsysania mieszaniny parowo-powietrznej oraz czasu na intensywność procesu odparowania filmu wodnego. Eksperyment przeprowadzono dla temperatury podgrzewanej powierzchni wynoszącej 90°C. Na podstawie analizy wstępnych wyników badań doświadczalnych oszacowano, że odsysanie mieszaniny parowo-powietrznej z wnętrza przestrzeni zwiększa intensywność odparowania chłodziwa (wody) o około 5÷30%, gdy czas chłodzenia wzrasta trzykrotnie. Zmiana miejsca odsysania mieszaniny parowo-powietrznej nie zmienia istotnie intensywności odparowania filmu wodnego.
EN
The paper presents test stand, research methodology and preliminary results of an experimental cooling of hot surface by stream of water droplets when the resulting steam-air mixture is sucked - off from the confined space surrounding the heater. Experiments were carried out for three cases of cooling process. In the first case steam-air mixture was sucked off from the confined space over heated surface through the outlet at the lateral surface of glass cover, in the second case mixture was sucked off from the center of the confined space over the hot surface and in the third case mixture in question was not sucked off. The vacuum pump was used for suction of steam-air mixture. The paper is aimed at analysis of effect location of steam-air suction point and time on intensity of water film evaporation. The temperature of the heating plate surface during experiments of 90°C. Based on preliminary analysis of the experimental results it was estimated that suction of vapor – air mixture from the interior of the confined space increases the intensity of cooling fluid (water) evaporation of approximately 5-30%, when the cooling time is increased threefold. Change in location of vapor-air suction mixture point enables to increase the intensity of water film evaporation is too high.