tom Nr 3
48--54
EN
The article presents the results of conditions of circular distribution of seismic vibrations generated during rock blasting. The Scales of Dynamic Influences [SWD] of the harmfulness of the vibration velocity on a two-storey building [SWDI] and a five-storey building[SWDII] are given. The value of seismic velocity safe for the construction of the buildings has been determined. They are in Zone II of the Dynamic Influence Scale [SWD] SWD I and SWD II. The magnitude of the components of the vibration velocity at the same distance from the source of vibration depends on the directional angle between the line of blast holes and the line connecting the centre of the surface of the mined rock block and the place of measurement. For the circular distribution of the vibration velocity, a theoretical analysis of the change in the radial value Vx and the tangential Vy of the vibration velocity depending on the change in the directional angle was conducted. Graphs of vibration velocity for circular distribution, measured during mining of rocks and complying with theoretical predictions were presented. For residential buildings, with SWDI and SWDII, the limit value of the safe vibration velocity for the building structures is given.
PL
W artykule zaprezentowano wyniki badań dotyczących polaryzacji drgań sejsmicznych rejestrowanych systemem czujników zamontowanych na koronie i u podstawy wału otaczającego zbiornik odpadów poflotacyjnych. Żelazny Most niedaleko Lublina. Artykuł zawiera niezbędny opis teoretyczny dotyczący metodyki interpretacji oraz obiektu badań. Zasadnicza część dotyczy wyników analizy polaryzacji najsilniejszych części zapisów sejsmicznych i dyskusję o ich ewentualnym wpływie na stateczność obwałowania zbiornika.
EN
The results of the polarisation analysis of the seismic waves recorded by the array of the sensors located near the flotation reservoir in Zelazny Most is presented in the paper. The sensors were located on the top and in the bottom of the dam surrounded the reservoir. The theoretical description of the polarization estimates and the object of the research are described. The description of the results of the analysis and the discussion of their influence on the embankment stability are the essential parts of the paper.
PL
W artykule przedstawiono w zarysie problem oceny negatywnego wpływu drgań, powodowanych robotami strzałowymi prowadzonymi w kopalniach odkrywkowych, na obiekty zlokalizowane w otoczeniu. Zasygnalizowano konieczność zmiany sposobu analizy drgań i zaproponowano zastosowanie filtracji tercjowej jako jednej z metod pozwalających na poprawę jakości prowadzonych analiz i wiarygodności stawianych diagnoz.
EN
The article shows the problem of estimation of negative influence of vibrations, caused by shooting in open mines, on the objects located in that area. It also shows the necessity of change of the methods of the vibration estimation and suggests the use of terce filters as a way to improve the quality of analysis led and the reliability of the diagnosis given.
|
|
tom nr 6
325--334
PL
Krajowa praktyka oceny stanu dynamicznego turbozespołów parowych jest realizowana w różny sposób w różnych elektrowniach. Do przełomu lat 80./90. ubiegłego wieku w tym celu wykorzystywano przede wszystkim pomiary drgań stojaków łożyskowych. Na początku lat 90. zaczęto wprowadzać pomiary drgań względnych wirników, natomiast w dalszym ciągu wykorzystywane były równolegle pomiary drgań sejsmicznych prowadzone dla stojaków łożyskowych. W artykule rozpatrzono następujące zagadnienia: API 670 i nadzór drganiowy dużych turbozespołów, podstawowe standardy ISO przydatne dla nadzoru drganiowego turbozespołów, proponowane kryterium wyboru rodzaju pomiaru drgań maszyn wirnikowych, instalację czujników drgań wału, tradycyjną instalację czujników drgań sejsmicznych, dewiacje w aplikacjach czujników drgań sejsmicznych, poprawną instalację czujników na turbinach dużych mocy, krajowe doświadczenia z pomiarami drgań absolutnych wirników, niepoprawną instalację czujników drgań na turbinach, zabezpieczenie turbozespołu na podstawie drgań. Stwierdzono, że możliwie najlepsze skonfigurowanie czujników na turbozespołach zapewnia możliwość najbardziej efektywnego wykorzystania systemu diagnostyki tak na etapie prób uruchomieniowych nowego bloku, jak i na okoliczność oceny poprawności przeprowadzonych prac remontowych w trakcie długich lat pracy bloku, a także umożliwia wczesne rozpoznawanie dewiacji ST.
EN
National practice concerning the assessment of steam TG units dynamic condition is realized in different ways in various power plants. Until the late 1980s/early 1990s first of all the measurements of bearing pedestal vibrations were made. With the beginning of 1990s the measurements of rotor relative vibrations were introduced while still the seismic vibrations measurements of bearing pedestals were carried on. In this paper the following items were considered: API 670 and big unit vibrations monitoring, basic ISO standards useful for big unit vibrations monitoring, proposed selection criteria of type of measurements applied to rotating machinery, installation of shaft vibration sensors, traditional installation of seismic vibrations sensors, devations in applications of seismic vibrations sensors, correct installation of sensors on high-power turbines, national experience with measurements of rotor absolute vibrations, incorrect installation of sensors on turbines, protection of TG unit on basis of the obtained vibrations data. It is concluded that the best possible configuration of sensors on TG units ensures possibility of the most efficient use of a diagnostic system at the stage of a new unit start-up trials as well as the evaluation of correctness of repair works carried out during long years of a unit operation. It also enables early identification of technical condition deviation.
PL
Przedstawiono główne czynniki zagrożenia środowiskowego od robót strzałowych. Scharakteryzowano poszczególne rodzaje oddziaływań oraz podano metody wyznaczania granic stref bezpieczeństwa ze szczególnym uwzględnieniem ochrony obiektów kubaturowych. Określono sposoby i wytyczne ograniczania zagrożeń od drgań sejsmicznych, rozrzutu i podmuchu w kontekście eliminacji szkód górniczych. Opracowano zależności propagacyjne umożliwiające zidentyfikowanie związków przyczyno-skutkowych w układzie działalność górnicza a uszkodzenia obiektów.
EN
The paper presents main risks for the environment caused by shot-blasting work. Specific types of impact were presented, and methods of determination of safe zones were outlined, with a special focus on protection of buildings. The author defined methods of and guidelines for limitation of risk caused by seismic vibrations, dispersion and blast in respect of elimination of mining damage. Propagation dependencies were determined in order to identify the cause-and-effect relations between the mining activity and damage f' buildings.
|
|
tom nr 9
60--62
PL
W artykule udowodniono tezę, że w przypadku kołowego rozkładu prędkości drgań przy urabianiu skał materiałem wybuchowym [MW] występuje kierunkowość składowej poziomej radialnej i stycznej prędkości drgań, czyli że wielkość składowych prędkości drgań w tej samej odległości od źródła drgań zależy od kąta kierunkowego między linią otworów strzałowych i linią łączącą środek powierzchni urabianego MW bloku skalnego a miejscem pomiaru. W przypadku rozkładu kołowego prędkości drgań przeprowadzono analizę teoretyczną zmiany wielkości radialnej Vx prędkości drgań w zależności od zmiany kąta kierunkowego. Przedstawiono pomierzone podczas urabiania skał MW wykresy prędkości drgań w przypadku rozkładu kołowego zgodne z przewidywaniami teoretycznymi, a także zależności uwzględniające kąt kierunkowy przy obliczaniu maksymalnych wartości prędkości drgań, potrzebnych do określania bezpieczeństwa technicznego budynku.
EN
In the article proved the thesis that for the circular distribution of vibration velocity during mining with [BM], there is a directionality of the horizontal radial component and the tangential component of the vibration velocity.The magnitude of the components of the vibration velocity at the same distance from the source of vibration depends on the directional angle between the line of blast holes and the line connecting the centre of the surface of the mined rock block and the place of measurement. For the circular distribution of the vibration velocity, a theoretical analysis of the change in the radial value Vx of the vibration velocity depending on the change in the directional angle was conducted. Graphs of vibration velocity for circular distribution, measured during mining of BM rocks and complying with theoretical predictions were presented. The relationships taking into account the directional angle for calculating the maximum values of vibration velocity needed for determining the technical safety of a building are given.