The effect of the agitators confi guration, the agitator speed, the volumetric gas flow rate, the sucrose concentration in aqueous solution, and the yeast suspension concentration on the hydrodynamics of twoor three-phase systems in an agitated vessel with two agitators has been presented in this paper. The gas hold-up and the average residence time of the bubbles were measured in agitated vessel with a liquid height of H = 2D and the internal diameter of D = 0.288 m. The study was carried out for gas-liquid and biophase-gas-liquid systems, where the gas phase was air, the liquid phase was distilled water or an aqueous solution of sucrose (c = 2.5% mass., 5% mass.), and the biophase was a suspension of Saccharomyces cerevisiae yeast (ys = 1% mass.). The research results were analysed taking into account the inf uence of the type of the upper or lower agitator, agitator speed, gas flow rate, and type of liquid in the system on the gas hold-up and the average residence time of the gas bubbles. The experimental results were mathematically described.
Przedstawiono wyniki analizy eksperymentalnej hydrodynamiki układu ciecz-gaz w zbiorniku z dwoma mieszadłami. Analiza obejmowała określenie wpływu rodzaju cieczy (zdolności układu do koalescencji pęcherzyków gazu w cieczy) oraz typu górnego mieszadła na wartość udziału gazu zatrzymanego w cieczy oraz średniego czasu przebywania pęcherzyków gazu w cieczy w smukłym aparacie o średnicy D = 0,288 m. Dla obu zestawów mieszadeł znacznie wyższe wartości udziału gazu ę zatrzymanego w cieczy otrzymano w układach niewykazujących zdolności do koalescencji Korzystniejszy do zapewnienia dobrego rozproszenia gazu w objętości cieczy okazał się zestaw mieszadeł RT-A 315. W oparciu o otrzymane wyniki zaproponowano równanie, uwzględniające wpływ parametrów operacyjnych oraz właściwości fizycznych fazy ciągłej (zdolności układu do koalescencji pęcherzyków gazu w cieczy) warunki wytwarzania układu ciecz-gaz.
EN
Results of experimental analysis of gas-liquid system hydrodynamics in a double-impeller system are presented in the paper. The analysis concerned an effect of liquid phase type (ability of gas bubbles to coalesce) and a type of upper impeller on the gas hold-up and average gas bubbles' residence time in the tall double-impeller vessel of inner diameter D = 0.288 m. For both sets of impellers significantly higher gas hold-up values were obtained in non-coalescing systems. Better results of gas dispersion in a liquid volume characterize the RT-A 315 configuration. The equation considering an effect of operating parameters and a liquid phase type was proposed on basis of results obtained.
W pracy przedstawiono wyniki badań zawartości gazu zatrzymanego w cieczy oraz czasu przebywania gazu w cieczy w zbiorniku z mieszadłem i pionowymi przegrodami rurowymi. Badania wykonano w mieszalniku o średnicy wewnętrznej D = 0,634 m dla układu ciecz - powietrze, gdzie fazą ciekłą była woda lub wodny roztwór NaCl o stężeniu 0,4 kmol/m3 i 0,8 kmol/ m3. Do mieszania cieczy użyto mieszadła turbinowego Rushtona lub turbinowego Smitha. Pomiary zawartości gazu w cieczy oraz czasu przebywania gazu w cieczy wykonano dla zmiennych częstości obrotów mieszadła przy różnym natężeniu przepływu gazu. Otrzymane eksperymentalnie dane opracowano matematycznie.
EN
Studies of gas hold-up and residence time of gas bubbles are presented in the paper. Measurements were carried out in a tank of inner diameter 0.634 m for air-liquid systems with distilled water or aqueous solutions of NaCl of concentrations 0.4 kmol/m3 and 0.8 kmol/m3 used as liquid phase. The Rushton turbine or Smith turbine were employed for agitation. The measurements of gas hold-up and residence time of gas bubbles were performed for different values of agitator rotational frequency and gas flow rates. The experimental data were elaborated mathematically.