For more than 10 years, masonry units made of ACC turned out to be one of the most popular materials used in the construction of residential buildings in Poland and other European countries. The recommended technology for erecting such structures requires using thin bed joints and non-filled head joints. Unfortunately, masonry buildings erected using this technique are prone to damage and cracks. One of the methods to guarantee improvement of cracking resistance of this type of structure is using a special prefabricated reinforcement to be placed in bed joints. The main objective of the investigation presented here was to analyse the behaviour of unreinforced and reinforced, with prefabricated truss-type called MURFOR®, masonry walletts. All specimens were subjected to diagonal compression. Three groups of specimens were tested, each using a different mortar coating Testing was especially focused on the main technological problem of the proper adhesion between mortar and the reinforcement surface.
PL
Od ponad 10 lat elementy wykonane z autoklawizowanego betonu komórkowego są jednym z najbardziej popularnych materiałów stosowanych do wznoszenia budynków mieszkalnych zarówno w Polsce, jak i Europie. Zalecana technologia wykonywania konstrukcji z takich materiałów wymaga stosowania cienkich spoin wspornych i niewypełnionych spoin czołowych. Niestety konstrukcje wznoszone w tej technologii są podatne na zarysowania. Jedną z metod ograniczania zarysowań jest wprowadzenie do spoin wspornych prefabrykowanego zbrojenia. Głównym celem prezentowanych badań jest analiza zachowania się muru niezbrojonego oraz zbrojonego zbrojeniem typu MURFOR®. Badane elementy poddano ukośnemu ściskaniu. Przebadano trzy grupy elementów próbnych, różniące się sposobem otulenia zbrojenia zaprawą. W trakcie analizy zwrócono szczególną uwagę na główny technologiczny problem, dotyczący zapewnienia prawidłowej przyczepności zbrojenia do elementu murowego.
2
Content available remote Ograniczenie zarysowania strefy podokiennej muru z silikatów
80%
|
2016
|
tom nr 4
82--86
PL
W artykule opisano wyniki badań dotyczących ograniczenia zarysowań i sposób zniszczenia murów z bloczków wapienno-piaskowych. Na ich podstawie stwierdzono, że zarysowanie strefy podokiennej w niezbrojonych murach z elementów silikatowych wystąpiło w przypadku ok. 40% naprężenia niszczącego. Zastosowanie zbrojenia (niezależnie od typu) powodowało zwiększenie naprężeń rysujących model. Najlepsze było zbrojenie siatkami z tworzywa sztucznego oraz typu kratowniczka. Maksymalne zwiększenie naprężeń rysujących w murach zbrojonych, w porównaniu z modelami niezbrojonymi, wyniosło prawie 70%.
EN
The article describes the results of tests on the appearance of cracks and on the way of damaging spandrel panel walls made of sand-lime blocks. Based on the conducted tests, it was stated that the cracking of the zone under the window in the non-reinforced walls made of silicate elements appeared on the level of ca. 40% of the destruction stress. The application of all types of the reinforcement caused the increase of the stress that led towall cracking.The best reinforcement was made of glass fibers and reinforcement of truss type. The maximum increase of cracking stress in the reinforced walls was almost 70% in comparison to non-reinforced models.
|
|
tom nr 10
157--158
|
|
tom nr 4
19--22
PL
Zbrojenie w konstrukcjach murowych stosuje się w celu ograniczenia zarysowań i zwiększenia nośności ścian. W artykule opisano badania ścian z autoklawizowanego betonu komórkowego (ABK) w skali naturalnej, w których zastosowano nowy typ zbrojenia z siatki stalowej. Określono wpływ zbrojenia na strefę wokół okna. Prezentowane badania są kontynuacją wcześniejszych podobnych analiz, opublikowanych w miesięczniku „Materiały Budowlane” [1, 2]. Uzyskane wyniki badań porównano z wynikami opublikowanymi w [1, 2, 3].
EN
Reinforcement in masonry structures is used to reduce cracks' width and increase the load-bearing capacity of walls. The article describes the study of autoclaved aerated concrete (AAC) walls in a full scale. A new type of steel mesh reinforcement was used in the tests. The influence of the reinforcement on the zone around the window was determined. The presented research is a continuation of previous similar analyzes published in Building Materials [1, 2]. The obtained tests results were compared with the results published in [1, 2, 3].
|
|
tom R. 95, nr 1-2
67--72
PL
W pracy przedstawiono wyniki badań doświadczalnych 4 serii (łącznie 24 modeli badawczych) połączeń wzajemnie prostopadłych ścian wykonanych z elementów murowych z autoklawizowanego betonu komórkowego (abk) poddanych ścinaniu ze zginaniem. Badano modele referencyjne składające się z dwóch ścian połączonych prostopadle tradycyjnym wiązaniem murarskim oraz modele o takiej samej geometrii, ale ze zmodyfikowanym sposobem łączenia - z wykorzystaniem różnych, dostępnych na rynku typów łączników (blach, kratowniczek). Dokonano analizy dotyczącej nośności oraz morfologii i mechanizmu uszkodzeń modeli.
EN
The paper presents the results of experimental tests of 4 series (a total of 24 research models) of mutually perpendicular joints of walls made of autoclaved aerated concrete (aac) masonry elements subjected to shearing with bending. Reference models consisting of two walls connected perpendicularly with a traditional masonry bond and models with the same geometry, but with a modified method of connection - using various types of connectors available on the market (plates, trusses) were tested. An analysis of the load capacity, morphology and damage mechanism of the models was made.