Ten serwis zostanie wyłączony 2025-02-11.
Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  reactive power control
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote A novel method to identify critical Voltage Control Areas
100%
|
|
tom R. 88, nr 2
212-217
EN
The power system all over the world experience from time to time big failure leading to total lack of voltage over a large area - called blackout. This paper presents an automated method for preventing the voltage collapse. This method called VCA (Voltage Control Area) allows to calculate reactive power necessary to mitigate the grid and point out the weak knots where the reactive power should be injected. This method was applied and tested with Polish transmission network.
PL
Systemy elektroenergetyczne całego świata doświadczane są awariami, które zwykle prowadzą do całkowitego zaniku napięcia tzw. blackout’u. Poniższy artykuł przedstawia automatyczną metodę systemowego zapobiegania utracie stabilności napięciowej. Metoda VCA określa krytyczne obszary regulacji napięcia, tzw. obszary VCAs w systemie (z uwzględnieniem topologii, warunków i ograniczeń przesyłu oraz oblicza wymagane źródła mocy biernej, potrzebne dla zapewnienia bezpieczeństwa. Metoda przeszła pomyślnie wstępne testy dla krajowych sieci przesyłowych.
|
|
tom Nr 32
119--122
PL
W artykule przedstawiono opracowany i zrealizowany przez Instytut Energetyki system regulacji napięć i mocy biernych dla węzła Dunowo obejmujący stację elektroenergetyczną najwyższych napięć oraz dwie, spośród wielu, przyłączone farmy wiatrowe. W treści zaprezentowano aktualne wymagania OSP dotyczące regulacji napięcia z wykorzystaniem farm wiatrowych. Przedstawiono budowę i strukturę wykonanego systemu, zasadę działania jego składników a także zasady koordynacji regulacji transformatorowej w stacji najwyższych napięć i generatorowej w farmach wiatrowych.
EN
Article describes control system designed in Institute of Power Engineering Gdańsk Division, which has been applied in substation Dunowo and nearby wind farms. Control systems uses wind farms in process of voltage and reactive power control. Presented are device structure, rules of control and requirements described in Instruction of Transmission System Operation and Maintenance (grid code) released by the Polish Transmission System Operator.
|
|
tom Nr 63
57--60
PL
Rozwój krajowej struktury wytwarzania energii oraz związanej z nią topologii sieci przesyłowej może skutkować w szczególnych przypadkach problemami z utrzymaniem wymaganych poziomów napięć i zwiększonym zapotrzebowaniem na regulację mocy biernej. Zapotrzebowanie na regulację mocy biernej ma charakter lokalny i wobec ograniczonej liczby potencjalnych dostawców, kontraktacja usługi przez OSP na zasadach konkurencyjnych jest trudna do przeprowadzenia. Jednostki wytwórcze zlokalizowane w KSE mają nieodpłatny obowiązek zapewnienia zdolności do generacji mocy biernej w określonym przepisami zakresie. Płatną usługą jest grupowa regulacja napięcia i mocy biernej w systemie ARNE. Obecny katalog usług regulacyjnych nie przewiduje zachęt ekonomicznych do oferowania zwiększonego w stosunku do wymagań zakresu regulacji mocy biernej. Mając na uwadze powyższe względy w referacie przedstawiono koncepcję wynagradzania za gotowość jednostek wytwórczych do udostępnienia szerszego zakresu regulacji mocy biernej, bazującą na wycenie kosztów związanych z utrzymaniem i eksploatacją majątku produkcyjnego zaangażowanego w świadczenie usługi.
EN
The development of the national energy generation structure (the concentration of wind energy in the northern part of Poland at the location majority of conventional power plants in the central and southern part) and the related topology of the transmission network may result in specific problems with maintaining the required voltage levels and increased demand for reactive power regulation. The planned implementation of projects for the construction of offshore wind farms in the Baltic Sea may deepen the above challenges. The demand for reactive power regulation is local and due to a limited number of potential suppliers that may use their market power, contracting a service by a TSO on a competitive basis is difficult to implement. The generating units located in the National Power System have a free obligation to ensure the capability of reactive power generation in the specified scope. Paid service is group regulation of voltage and reactive power in the ARNE system, provided by centrally available units. The current catalog of regulatory services does not provide for economic incentives to offer increased reactive power control in relation to the requirements. Bearing in mind the above considerations, the paper presents the concept of rewarding for the readiness of generating units to provide a wider range of reactive power regulation, based on the valuation of costs related to the maintenance and operation of the productive assets involved in providing the service.
|
|
tom Nr 62
143--147
PL
W pracy opisano przykład modelowania prototypowego układu regulacji napięcia i mocy biernej zgodnie z rozwiązaniami zawartymi w normach IEC 61850 (PN-EN 61850). Typowe urządzenia stosowane w energetyce oraz funkcje przez nie realizowane (zabezpieczenia, regulatory itp.) zostały ustandaryzowane i ujęte w normach jako kompatybilne klasy węzłów logicznych. Wiele urządzeń, zwłaszcza prototypowych lub stosowanych w mniejszej skali, nie posiada swojej reprezentacji w normach IEC 61850. Autorzy tych układów samodzielnie tworzą modele obiektów danych a następnie własne definicje węzłów logicznych postępując zgodnie z określonymi w normach zasadami. W Polsce takim przykładem są układy regulacji napięcia i mocy biernej dla stacji najwyższych napięć oraz elektrowni (ARST lub ARST/ARNE).
EN
The paper presents the example of modelling prototype voltage and reactive power control device according to the solutions contained in the standards IEC 61850 (PN-EN 61850). Typical devices used in power engineering and their implemented functions (protections, controllers, etc.) have been standardized and defined in the standards as a compatible class of logical nodes. Many devices, especially prototype devices or those used on a lesser scale, do not have their representation in IEC 61850 standards. The authors of these systems create models of data objects independently and next, their own definitions of logical nodes following the rules defined in the standards. In Poland, such examples are voltage and reactive power control systems for the highest voltage substations and power plants (ARST or ARST/ARNE).
|
|
tom Nr 47
47--50
PL
W artykule przedstawiono wyniki badań pokazujące możliwości wykorzystania baterii kondensatorów zainstalowanych wewnątrz sieci SN (w odbiorców przemysłowych), w celu zminimalizowania strat mocy w sieci elektroenergetycznej. Wyniki analizy pozwoliły określić, które ze stosowanych obecnie kryteriów regulacji jest najbardziej korzystne. Wskazywano również na konieczność koordynacji działań regulatorów transformatora i baterii kondensatorów.
EN
One of the main issues related to the optimization of the MV network is to reduce losses of active and reactive power. Lower losses of active and reactive power give not only economic advantage, but also improvement of energy quality. The object of regulation that can be used for these purposes are transformer with On-Load Tap Changer and capacitor's banks. This paper presents results of analysis of the possibility of using capacitor banks installed inside the MV network (in industrial consumer) in order to minimize power losses in the power network. The results of analysis allowed to determine which of the criteria adjustment: constant voltage or maintain constant values tgφ, in individual buses is better. It was also pointed to the necessity of the coordination between actions of regulators of the transformer and capacitor banks.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.