Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Ograniczanie wyników
Czasopisma help
Lata help
Autorzy help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 100

Liczba wyników na stronie
first rewind previous Strona / 5 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  reactive power
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 5 next fast forward last
1
Content available remote Measure of electric reactive power
100%
EN
Generated electric power can either be dissipated or occur in the form of an electric field and a magnetic field. By replacing the voltage in the well-known equation for dissipated power (energy) with its derivative (a function orthogonal to the voltage) the average electric and magnetic field power exchanged between an electrical object and the rest of the closed electric power system was obtained. The measure of the (reactive) power is the surface area of the closed loop, which the objects characteristic forms in current-voltage coordinates.
PL
Z równań elektrodynamiki wynika, że występują tylko dwa zasadnicze procesy elektroenergetyczne: energia elektryczna może być rozpraszana oraz może być gromadzona w postaci pola elektrycznego i magnetycznego. Proces rozpraszania energii elektrycznej można opisać za pomocą mocy czynnej, której miarą może być powierzchnia zamkniętej pętli jaką tworzy charakterystyka obiektu we współrzędnych prąd elektryczny - strumień magnetyczny. Dla opisu właściwości energetycznych obiektu stosuje się, oprócz mocy czynnej, również inne parametry mocy elektrycznej: moc pozorną oraz moc bierną. Moc pozorna jest największą wartością mocy czynnej możliwą do osiągnięcia dla danej wartości skutecznej napięcia. Moc bierna jest jednoznacznie zdefiniowana dla sinusoidalnych przebiegów napięcia i prądu. Dla przebiegów niesinusoidalnych moc bierną definiuje się, najczęściej przy założeniu, że prąd w przewodach systemu elektroenergetycznego da się rozłożyć na składowe ortogonalne. Badania prawdziwości tego założenia prowadzone są od ponad 70 lat. Jeśli moc bierna ma opisywać proces wymiany energii pola elektrycznego i magnetycznego, to jej miarę można określić podobnie jak miarę mocy czynnej. Ponieważ w obiekcie zachodzą tylko dwa podstawowe procesy elektroenergetyczne, z których jeden jest opisany przez moc czynną, to drugi można opisać zamieniając w równaniu definiującym moc czynną, na przykład napięcie, na pochodną napięcia względem czasu, czyli na funkcję ortogonalną do napięcia. Miarą tak zdefiniowanej mocy biernej jest powierzchnia zamkniętej pętli, jaką tworzy charakterystyka obiektu we współrzędnych prąd - napięcie. Miara ta jest jednoznaczna. Charakterystyka obiektu w tych współrzędnych redukuje się do odcinka linii (nie tworzy pętli), gdy parametrem zastępczym obiektu jest tylko rezystancja jednoznacznie zależna od napięcia, czyli gdy między obiektem a resztą systemu elektroenergetycznego nie jest wymieniana energia pola elektrycznego i magnetycznego. Takich właściwości nie mają charakterystyki w innych współrzędnych. Również moc bierna definiowana według innych koncepcji nie zawsze jest równa zeru, gdy w obiekcie nie ma zmiennego w czasie pola elektrycznego i magnetycznego. Jeśli zależność rezystancji zastępczej od napięcia nie jest jednoznaczna, to oznacza, że do obiektu jest dostarczana dodatkowa energia bezpośrednio nie pochodząca ze źródła napięcia, która zakłóca stan równowagi powodując dodatkowe oscylacje, a więc pojawienie się mocy biernej.
EN
This note addresses some issues raised in [4] and refines some assertions made in our previous work on the time-domain Currents’ Physical Components (CPC) decomposition in [10].
|
|
tom Nr 3 (64)
11-14
PL
Do nadrzędnej regulacji napięcia w węzłach elektrownianych i sieciowych w Krajowym Systemie Elektroenergetycznym powszechnie stosowane są układy ARNE i ARST, przy czym nazwy stały się w istocie synonimami regulacji nadrzędnej napięcia i mocy biernej. Wzrost nasycenia systemu elektroenergetycznego farmami wiatrowymi da możliwość, a w niektórych przypadkach być może wymusi konieczność, włączenia tych obiektów do regulacji nadrzędnej węzłów. W artykule przedstawiono ogólne struktury i algorytm regulacji nadrzędnej napięcia uwzględniający farmy wiatrowe. Artykuł recenzowany.
EN
ARNE and ARST control systems are widely used in Polish power system for the substations’ terminal voltages and reactive powers control. The wind farms number and capacity increase in high voltage power systems gives opportunity for (and sometimes will force) the farms use for the remote substations’ terminal voltages or reactive powers control, realized today by the ARNE and ARST controllers. The paper presents an idea of the wind farms use for those control processes. The general idea of algorithms and structures are presented.
5
Content available remote Moc bierna i jej fizyczne interpretacje
100%
PL
Artykuł poświęcony jest analizie zgodności występowania mocy biernej z realnymi zjawiskami rzeczywiście zachodzącymi w obwodach elektrycznych. Jest próbą porządkowania zgromadzonej na ten temat wiedzy i sformułowania postulatów, które musi spełniać moc bierna. Identyfikuje zjawiska fizyczne odpowiedzialne za moc bierną.
EN
The paper deals with analysis of conformity of reactive power with real physical phenomena that occur in electric network. It gives an attempt to systematise knowledge concerning the issue and to specify presumptions reactive power should fulfil. It quotes physical phenomena that are responsible for appearance of reactive power.
EN
In many countries, the grid-code or standards do not allow the Photovoltaic (PV) inverters to exchange reactive power with the grid. Recently, some countries have relaxed the standards. Hence, capacity of the inverters to control reactive power must be utilized. However, the reactive power that a PV inverter can supply is constrained by the maximum power that a PV array generates and changes with the environmental conditions. A reactive power sharing algorithm is proposed that not only ensures proper distribution of reactive power amongst the inverters, but also ensures that the maximum power generated by PV is supplied to the grid. In case of identical PV inverters, the algorithm operates all inverters at nearly equal apparent power leading to nearly equal percentage utilization of the inverters, thereby achieving uniform heating of the similar devices of the inverters. The algorithms are further investigated for power sharing amongst PV inverters of unequal ratings. It is highlighted that the proposed algorithm results into the least change in the utilization factor of a PV inverter, whose power changes due to the change in environmental conditions. The effectiveness of the algorithm over other algorithms in sharing power amongst inverters is displayed through MATLAB/Simulink simulations.
EN
This paper deals with problems of reactors utilization on overhead transmission lines in order to balance reactive power. This compensation is necessary in case when power transmission is lower then natural capacity or there are no load condition. Rated power of reactors depends on natural capacity and length of the line.
EN
Recently the authors have developed a time-domain representation of the Currents’ Physical Components (CPC) power theory. Consequently, piece-wise continuous currents and voltages, such as square waves and sawtooth signals, can naturally be taken into account without approximating them by a finite number of harmonics. Based on the time-domain CPC approach, this paper refines and corrects some of the assertions made by Czarnecki in his paper ‘Physical Interpretation of the Reactive Power in Terms of CPC Power Theory’.
|
|
tom No. 69
89--93
EN
This paper develops an optimization model to control the excessive (MVAR) generation by super high voltage gird systems for maintaining the nodal voltages within the required acceptable margin. The model enhances an approximate solution on the condition of balanced real power. The pseudo-inverse method of optimization is implemented as an optimal optimization is implemented as an optimal means of solving non-square systems of equations based on LaGrange's theory of optimization. It recommends the locations and ratings of the minimum required reactors from the preinstalled ones that to be in service for optimum nodal reactive power and voltage controls.
EN
Increasing numbers of devices of various types are now connected to power lines. Their nonlinear nature harms the operation of the lines, as the line voltage is distorted from a sine wave, which causes disturbances in the operation of other loads. This study proposes a method of active parallel compensation that can be realised using a power supply. The proposed device is a dual-function system: it supplies the load connected to its DC link, and operates as a parallel active filter. This kind of device, with a relatively low value of the rated output power, could be implemented in electrical systems to provide distributed compensation. The second novel aspect of this work is the use of a tunable inductive filter, which is included at the input of the power electronics controlled current source and forms a main part of the power supply. The use of this tunable inductive filter increases the frequency response of the current source, while at the same time, in the quasi-steady state of power supply operation, the pulse modulation component of the input current source remains at a minimum level. This paper discusses the structure of an electrical system with the proposed power supply and the rules of operation for the system, and presents test results based on both a simulation and a laboratory model of the system.
EN
In heavily loaded systems, voltage stability limit is usually dominant and voltage instability is usually observed following large disturbance. This is typically the case in the deregulated environment as the transmission systems are operating under more stressed condition due to increased transaction level associated with open access. In this paper simple voltage stability analysis is carried out for a multibus power system (26 Bus System).The effect of shunt compensation on critical eigen value of Jacobian matrix, system loadabilty and static voltage stability is established.
PL
W systemie przeciążonym jednym z najważniejszych parametrów jest stabilność napięcia. W artykule przeprowadzono analizę stabilności napięcia w wieloszynowym systemie (26 szyn).
EN
The work presents a DC power supply with power factor correction (PFC). This device is also equipped with a parallel active filter function, which enables the possibility of compensation (minimization) of reactive and distortion power, generated by a group of loads, connected to the same power grid node. A passive filter with variable inductance applied at the input of the power supply allows for a significantly improvement in quality of the system control (given specific criteria), as compared to the solution with a filter with fixed parameters. This is possible by increasing the dynamics of current changes at the power supply input (extending its “frequency response”). The paper presents the principle of operation as well as structures and models of the power supply control system and its power stage. Selected test results its power of the simulation model of the electric system with the power supply, in various operating conditions, are also presented.
EN
Asynchronized (doubly-fed) machines with two (three) excitating winding and reversing excitation system allow to control vector of magnetomotive force. This solution allows separating regulation of the electromagnetic torque (active power) and voltage (reactive power). This paper describes the experience in the development and operation of asynchronized turbogenerators and condensers.
|
|
tom R. 96, nr 11
124--127
EN
This article presents a control of a three-phase low voltage grid connected fuel cell system which participating in the improvement of the quality of energy at the connection point by ensuring the reactive energy compensation, the active power control and the harmonic filtering functionalities. A p-q theory based control has been developed to control the injected fuel cell active power and to allow the system to provide the reactive energy compensation function. The system is structured around a proton exchange membrane (PEM) fuel cell system and a three-phase voltage inverter.
PL
W artykule przedstawiono sterowanie trójfazową siecią z podłączonym ogniwem paliwowym z kompensacją mocy biernej i redukcją harmonicznych. Zastosowano ogniwo z protonową membraną wymienna PEM.
PL
W artykule poruszono tematykę projektowania i wykonawstwa instalacji fotowoltaicznych. Scharakteryzowano wymagania techniczne budowy instalacji fotowoltaicznych oraz wskazano czynniki, które należy uwzględnić przy ich poprawnym projektowaniu. Przedstawiono również tematykę związaną z potencjalnymi karami za moc bierną pojemnościową oraz sposoby ich uniknięcia w przyszłości.
EN
The paper deals with the design and construction of photovoltaic installations. The technical requirements for the construction of photovoltaic installations are characterized and factors to be taken into account when designing them properly are indicated. It also presents the issues related to potential penalties for capacitive reactive power and how to avoid them in the future.
PL
Przedstawiono system teleinformatyczny służący do kompensacji mocy biernej opracowany w Instytucie Tele- i Radiotechnicznym.
EN
The paper presents data communications system for reactive power compensation systems, workout in Tele and Radio Research Institute.
|
|
tom Nr 40
33-36
EN
This paper addresses the problem of voltage sags during various modes of operation of the directly connected 6 kV squirrel cage induction motor. Simulink model was employed in order to investigate the system dynamic performance and countermeasures against voltage sags upon motor start, rapid load change and steady state operation. Paper presents the comprehensive approach to the analysis of such phenomena using various computer tools. A simple method to extract detailed data of the squirrel cage induction motor using INDSYNW (EMTP-ATP subroutine) is presented herein. Simulink results were additionally verified using NEPLAN.
PL
Artykuł prezentuje analizę zapadów napięć w sieciach SN podczas pracy silnika indukcyjnego klatkowego dużej mocy przy użyciu wybranych programów. Dzięki zastosowaniu aplikacji INDSYNW służącej do oszacowania szczegółowych danych silników, możliwe jest wykonanie analiz nie tylko podczas stanu ustalonego, lecz także w czasie rozruchu lub przeciążenia maszyny. Analizę przeprowadzono w programach NEPLAN oraz Simulink.
PL
Zwrócono uwagę na źródła mocy biernej w systemie elektroenergetycznym i sposoby jej wytwarzania, omawiając nowe rozwiązanie techniczne modernizacji stacji NN.
EN
The attention is paid to sources and methods of generating reactive power in power system. New technical solutions to problem of modernization of LV station are discussed.
|
|
tom nr 11
702--705
PL
Moc bierna jest wielkością techniczną, charakteryzującą obwody elektryczne prądu przemiennego, niemającą swojego bezpośredniego odpowiednika w mechanice. Obecność mocy i energii o charakterze biernym jest konieczne do prawidłowego działania wielu odbiorników energii. Moc bierna jest również wielkością wpływającą na prawidłową pracę sieci oraz systemów elektroenergetycznych i podobnie, jak moc czynna powinna być na bieżąco bilansowana. Przesył mocy biernej może powodować negatywne skutki, w szczególności wpływające na obniżenie sprawności (efektywności energetycznej) dostarczania energii do odbiorców, wyrazem świadomości czego są zapisy w krajowym prawodawstwie z zakresu efektywności energetycznej (Ustawa o efektywności energetycznej). Problem odpowiedniego kształtowania opłat za użytkowanie mocy biernej oraz prowadzenia rozliczeń za pobór i generację mocy i energii biernej w systemie elektroenergetycznym wydaje się być dotąd nierozwiązany. Świadczą o tym ­krytyczne głosy w stosunku do obecnie stosowanych metod rozliczania, obowiązujące w różnych krajach odmienne sposoby takich rozliczeń, różne propozycje kształtowania opłat, a co więcej różne koncepcje definiowania samego pojęcia mocy biernej. W artykule przedstawiono wybrane zagadnienia związane z tematyką prowadzenia rozliczeń za użytkowanie mocy biernej, przegląd obecnie stosowanych metod i nowych propozycji, zwracając uwagę na konieczność uporządkowania zagadnienia, zwłaszcza w kontekście wdrażania sieci inteligentnych i rozwoju instalacji prosumenckich, tworzenia konkurencyjnego rynku energii, aktualnej problematyki poprawy efektywności energetycznej oraz racjonalnego gospodarowania energią elektryczną.
EN
The reactive power is a technical term characterizing alternative current circuits and having no direct equivalent in mechanics. The presence of power and energy of a reactive character is necessary for proper functioning of many energy receivers. Reactive power is also a factor having influence on proper operation of networks and power systems and, like active power, should be balanced on an ongoing basis.Transmission of reactive power can cause negative effects causing particularly reduction of efficiency (energy efficiency) of energy supply to endusers and is reflected in provisions included in the current national legislation concerning energy efficiency (Energy Efficiency Improvement Act). But the problem of proper fees formation for reactive power utilization as well as conducting of clearing of accounts for generation and consumption of power and reactive energy in power systems seems to be unsolved so far. It is indicated by criticisms expressed about the presently used ­clearing methods that are different in various countries, various ideas of fees shaping and, what is more, various concepts concerning the definition of the term „reactive power” itself. Presented are here selected problems relating to clearing of accounts for reactive power utilization and a review of the presently used methods and new proposals. Special attention is called to the necessity of making a complex arrangement of this issue, especially in the context of intelligent networks implementation and development of prosumer installations, creation of competitive energy market, current problems related to energy efficiency improvement and electric energy rational management.
20
Content available remote Moc bierna (moc nieczynna), moc, czy deficyt mocy?
75%
PL
W artykule przedstawiono fizyczne przyczyny występowania zjawiska przepływu energii w systemach elektrycznych, interpretowanego jako występowanie mocy biernej (mocy nieczynnej). Rozwinięta została teza prof. Fryze głosząca, iż zjawisko to występuje wtedy, gdy przebiegi prądów i napięć nie są w tych systemach do siebie proporcjonalne. Krytycznej analizie poddana została dominująca obecnie koncepcja,tłumacząca występowanie tego zjawiska oscylacjami energii pomiędzy odbiornikiem i źródłem. Analiza problemu rozpoczyna się od przypomnienia pojęć podstawowych.
EN
The paper presents the physical meaning of the phenomenon of energy transfer degradation in electrical systems interpreted as the occurrence of reactive pow er (nonactive power). It develops the thesis of prof. Fryze that the phenomenon occurs when in these systems currents and voltages waveforms are not proportional to each other. Moreover, the critical analysis o f the concept explaining this phenoenon as the effect of energy oscillations between load an d source has been discussed. It starts with the review of basic concepts.
first rewind previous Strona / 5 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.