There are various uses for radioisotope devices, also in metrology, broadly conceived. Most often, absorption systems are used. Such systems, though familiar and used for many years, lacked theoretical and methodical descriptions. The monograph aims at filling this gap. The work presents the results of the studies on the absorption system with the use of betaradiation sources, which are often used in measurements of two-phase gas-solid flows. The influence of the radiation beam collimation on the radiation attenuation coefficient as well as the measurement error related to changing location of the absorbent in the measurement have been measured, the interaction of the beta-particle beam with the homogeneous and heterogeneous absorbents and the optimum parameters of such systems have been provided. The model of the radiometric system has been described and the results of the experimental tests of this model have been presented. An original method for calculating the coefficients of radiation attenuation in dispersed absorbents as well as the results of the experiments have been given. The monograph is addressed to both metrology experts and practising constructors who deal with the application of ionising radiation.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Przedstawiono wyniki wieloletnich pomiarów promieniowania słonecznego na płaszczyznę nachyloną, prowadzonych w SGGW. Wyznaczono średnie, maksymalne i minimalne sumy miesięczne promieniowania, średnie sumy dobowe i rozkłady ich częstości. Przeprowadzono porównanie wartości sum dobowych mierzonych i obliczanych, przy wykorzystaniu danych IMGW odnoszących się do płaszczyzny poziomej.
In this paper we present the accuracy analysis of energy and temperature measurements for testing and productivity improvement of solar collectors. There are presented possibilities of accuracy and resolution increase of solar energetic luminance sensors. The radiometer with electrical substitution was used in the research. The calibration procedure of the radiometer is described. A mathematical model of conversion function for both temperature and temperature difference measurement was developed as well.
PL
W pracy przedstawiono analizę dokładności pomiaru energii słonecznej i temperatury za pomocą radiometrów z elektrycznym zrównoważeniem. W celu zwiększenia dokładności oraz rozdzielczości radiometrów zaproponowano zastosowanie połączonych równołegle miniaturowych sensorów diodowych do pomiaru różnicy temperatury powierzchni absorbującej kolektora słonecznego oraz otoczenia. Dodatkowo, diody te wykorzystano do nagrzewania sensora w czasie kompensowania. Pokazano, że taka konstrukcja sensora radiometrycznego pozwala odtwarzać temperaturę powierzchni przejmującej. Wykazano, że adytywne i multiplikatywne składniki błędów spowodowane rozrzutami technologicznymi napięć początkowych oraz prądów pomiarowych sensorów diodowych mogą być zmniejszone około razy, przy jednoczesnym zwiększeniu czułości w n razy, gdzie n jest liczbą równolegle połączonych diod. Opisano procedurę kalibracji radiometru przy zerowej i bliskiej maksymalnej mocy promieniowania. W pierwszym przypadku można skorygować addytywny, a w drugim – większość multiplikatywnych składników błędu. Zaproponowano schemat blokowy przyrządu do precyzyjnych pomiarów różnicy temperatury. Zastosowano wielokanałowe mierniki rezystancji z platynowymi sensorami temperatury. Do kalibrowania miernika różnicy temperatury wykorzystano precyzyjne miniaturowe rezystory, a do kalibrowania całego toru pomiarowego użyto precyzyjny termostat sterowany programowo. Opisano także konstrukcję stanowiska do pomiarów parametrów kolektorów słonecznych w laboratorium badawczym w Narodowym Uniwersytecie „Lwowska Politechnika”.
Automatyzacja produkcji oraz stosunkowo niskie koszty opracowania powodują, że ortofotomapa stała się jednym z ważniejszych a być może najpopularniejszym produktem geoinformatycznym. W sytuacji masowego wykorzystywania ortofotomapy, co widać zwłaszcza w geoportalach internetowych, coraz większej wagi nabiera ocena jakości. O ile jakość geometryczna jest względnie łatwa do oceny to zgoła inaczej jest z jakością radiometryczną. W publikacji zwrócono uwagę na fakt, że w stosunku do ortofotomapy trafniej jest mówić o jakości fotometrycznej niż radiometrycznej. Dla uzasadnienia tezy opisano ogólną różnicę pomiędzy radiometrią a fotometrią a w szczególności przeanalizowano czym jest rozdzielczość radiometryczna a czym fotometryczna. W dalszej części pracy przedstawiono próbę kompleksowego zdefiniowania pojęcia jakość fotometryczna ortofotomapy. Uznano, że jakość fotometryczna ortofotomapy to stopień spełnienia przez obraz (o określonej rozdzielczości geometrycznej) szeregu warunków kształtujących jego przydatność do interpretacji treści. Następnie omówiono poszczególne warunki determinujące jakość fotometryczną podając każdorazowo możliwości ilościowej oceny spełnienia danego warunku.
EN
The automation of the production and relatively low costs of development imply that the orthophotomap is one of the more important and probably the most popular geo-information technology product. Due to the global application of the orthophotomap as it is particularly evident in case of web geoportals, the quality assessment becomes more and more important. While the geometric quality is relatively easy to assess, it is far more difficult to rate the radiometric quality. The paper emphasises that it is more accurate to employ the term of the photometric quality instead of the radiometric quality in relation to the orthophotomap. In order to prove the thesis, general difference between the radiometry and the photometry was characterised and, in particular, the paper analysed the notions of the radiometric density and of the photometric density. Furthermore, the paper features the concept of the complex definition of the orthophotomap photometric quality. It has been accepted that the orthophotomap photometric quality is the ratio featuring in what way an image (of the specified geometric resolution) complies with a number of conditions defining its usability for the interpretation of the content. Thereafter, individual conditions determining the photometric quality are characterized, specifying each time whether it is possible to assess quantitatively the fulfilment of the given condition.
W dziedzinie techniki zajmującej się pomiarami odebranego promieniowania wyróżnia się radiometrię szumową związaną z detekcją promieniowania o strukturze szumowej, którego widmo mieści się w paśmie mikrofalowym. Źródłem tego promieniowania są organizmy żywe oraz przedmioty i substancje, których temperatura jest wyższa od zera bezwzględnego. Pomiar tego rodzaju promieniowania jest realizowany za pomocą radiometru mikrofalowego składającego się z anteny (głowicy pomiarowej), wzmacniacza z detektorem oraz wyjściowego układu analizującego i rejestrującego. W artykule przedstawiono zasadę działania i parametry robocze radiometru modulacyjnego pracującego na częstotliwości 1,5 GHz. Opisano wybrane wyniki prac badawczych prowadzonych w Zakładzie Mikrofal IRE WEL WAT nad bezinwazyjnymi metodami lokalizacji stanów patologicznych wewnątrz organizmów żywych oraz biernymi systemami wykrywania obiektów o temperaturze fizycznej wyższej lub niższej niż temperatura ich otoczenia. Przedstawiono wyniki badań eksperymentalnych weryfikujących przyjęte hipotezy.
EN
Microwave thermal radiation of various objects can be used for their location and identification. Thermovision in the infrared range enables us to find temperature distribution on the object surface while microwave radiometers allow us to recognize "hot" objects placed, for instance, behind thermal shields. Microwave radiometers are used, among the others, in health care and in so-called special applications. In medicine, they are used both in diagnostics and therapy where, for example, microwave radiometers control temperature in hypo- or hyperthermia or they can monitor pathological states of internal organs, detect pap tumour, or are used for temperature measurements of acupunctural points. Special applications of microwave radiometers focus on passive location of various equipment like tanks, planes, cars, trucks and so on. A separate group of applications deals with detection of humans or "hot" objects located behind shields. Performed experiments confirmed capability of developed radiometer to remote detection of live objects and subjects with temperatures different from the background. The tested instrument was equally effective in observation of non-shielded objects as well as for objects hidden behind dielectric shield. The principle of operation of the 1.5 GHz microwave radiometer and selected results of the experiments there were presented.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.