In this paper, a new reference current generation method is proposed for effective harmonics mitigation and reactive power compensation of three-phase shunt active power filter (SAPF) under grid perturbations. The proposed reference technique is specified as a self-regulator of dc-capacitor voltage. In operation, the proposed algorithm estimates the source reference current rapidly and adaptively through power system disruptions arising at source as well as load sides. The proposed technique employs the Robust Extended Complex Kalman filter (RECKF) algorithm to generate reference current, which confirms in phase action of SAPF with the functional power system, without being reliant upon any phase-locked loop (PLL) elements or proportional integral (PI) controller loop. As a consequence, an economical SAPF system can be designed. More-over, a Linear Quadratic Regulator (LQR) is formulated using RECKF methodology for delivering stability and robustness in the SAPF system. The design model and efficacy of the proposed algorithm are fully studied and assessed in a laboratory prototype employing dSPACE1104 to justify feasibility. The encouraging outcomes obtained experimentally demonstrate the efficiency of the proposed approach under both steady and dynamic conditions of the power system.
PL
Artykuł przedstawia analizę pozwalającą na wyznaczenie równania różniczkowego, opisującego obwód regulacji prądu wyjściowego falownika filtru aktywnego z dodatkowym pomiarem sieciowego napięcia zasilającego. Otrzymane równanie pozwala na wyznaczenie warunków, zapewniających stabilną pracę filtru przy obciążeniu o charakterze pojemnościowym. Wyniki analizy zostały potwierdzone komputerowymi badaniami symulacyjnymi oraz eksperymentalnymi komercyjnego filtru aktywnego.
EN
This article presents an analysis that allows determination of the differential equation describing the output current control circuit of the active filter inverter with an additional measurement of line input voltage. The resulting equation allows to determine the conditions which ensure the stable operation of the filter with capacitive load. The results of the analysis were confirmed by computer simulation and experimental studies of commercial active filter.
PL
W artykule przedstawiono wyniki badań symulacyjnych równoległych, energetycznych filtrów aktywnych w różnych warunkach pracy. Porównano typowy układ równoległego filtra aktywnego, pracujący w oparciu o pomiar odkształcenia prądu odbiornika z układem pracującym na bazie identyfikacji odkształceń napięcia sieci.
EN
The articles presents the results of a simulation research on the Parallel Active Power Filters (PAPF) in various working conditions. A typical, most often used device of an APF working on the basis of the current distortion has been compared with the device working on the basis of the identification of the network's voltage distortion.
EN
The shunt active power filter (SAPF) and hybrid active power filter (HAPF) efficiency does not only depends on their designed control system, but also on the parameters of the electrical system in which they are connected. In the electrical system for instance with diode or thyristor rectifier loads, the operating efficiency of the shunt active power filter may not be satisfied at the commutation times, when the rate of current change (di / dt) is high. In the topology of HAPF where the active and passive filters are connected in parallel, the passive filter efficient may depend on the grid parameters. Therefore, the efficiency of such filters can be in certain cases improved by connecting an additional line-reactor in the electrical system. This paper presents an investigation on the influence of the additional line-reactor on the SAPF and HAPF efficiency. The investigation is based on laboratory experiments.
PL
Wydajność filtru aktywnego i hybrydowego zależy nie tylko od zaprojektowanego układu sterowania, ale także od parametrów obwodu elektrycznego, do którego są one podłączone. W układzie elektrycznym obciążonym na przykład prostownikiem diodowym lub tyrystorowym, efektywność pracy równoległego filtru aktywnego może nie być satysfakcjonująca w chwilach komutacji, gdy szybkość zmian prądu (di / dt) jest wysoka. W topologii HAPF, gdzie filtr aktywny i pasywny są połączone równolegle, skuteczność filtru pasywnego może także zależeć od parametrów sieci. W związku z tym, wydajność takich filtrów można, w niektórych przypadkach, poprawić przez dodatkowy dławik liniowy w obwodzie elektrycznym, do którego podłączone są filtry. W niniejszej pracy przedstawiono badania wpływu dodatkowego dławika liniowego na wydajność filtru aktywnego i hybrydowego, które opierają się na eksperymentach laboratoryjnych.
5
67%
EN
This paper describes a shunt active power filter for compensating harmonic currents and reactive power. The shunt active power filter (SAPF) was implemented with a phase pulse modulated current control voltage source inverter. The proposed system is based on PLL synchronization with reduced fuzzy logic controller (RD-FLC). These control techniques for SAPF prove that source current is sinusoidal even when load is nonlinear. The CC-VSI inverter switching is done according to gating pulse obtained from the hysteresis controller using RD-FLC controller. The proposed system is investigated using simulation results. The effectiveness of the controller is observedin the form of total harmonic distortion, reactive power compensation and settling time of dc link voltage under non linearload condition. This technology reduced the rules of fuzzy logic controller from 49 to 37.