Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Ograniczanie wyników
Czasopisma help
Lata help
Autorzy help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 25

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  pulse
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
1
100%
EN
Finnish sauna is one of the most popular among all the saunas types and as a result is the most commonly used. Bath in the Finnish sauna is a combination of heating with a warm and dry air and the short influence of high humidity and cooling with cold water and air. The article aims to identify pulse and blood pressure in the conditions of thermal heating in the sauna among women and men between the age of 20-25. Hypothetically sauna has a great influence on the basic hemodynamic parameters such as pulse and blood pressure. There were 127 healthy, young women and 74 men, students at the University of Physical Education in Wroclaw taking part in the experiment. Average age of the volunteers was 21.5 and 21.7.The results indicate that a bath in the Finnish sauna leads to a significant increase of the pulse among men and women. Concurrently the results show a considerable decrease in diastolic pressure, with the systolic pressure remaining at almost the same level. It can be concluded that a bath in a Finnish sauna positively influences the hemodynamics of blood pressure and pulse. A series of bathes in the Finnish sauna leads to a considerable decrease of the systolic and diastolic pressure and an increase of the pulse among male and female volunteers.
EN
Development of condensed energetic systems, especially photosensitive primary explosives for the systems of laser initiation is one of the foremost fields of application of energetic materials. There have been synthesized and investigated a coordination complex of mercury(II) chlorate(VII) with 5-hydrazinotetrazole as ligand (compound (I)) as a potential photosensitive primary explosive. This complex consisting of particles of 1.1 0.8 m size demonstrated the highest sensitivity to laser irradiation combined with an extremely low initiation threshold. On the basis of compound (I) a photosensitive formulation EC-2 containing ∼ 90% of the complex mercury(II) chlorate(VII) and ∼ 10% of an optically transparent polymer as an inert matrix has been proposed. Formulation EC-2 has extremely high sensitivity to Q-switch IR-laser irradiation. Formulation EC-2 with added ultra disperse diamonds (UDD) has shown lower initiation thresholds in comparison with neat EC-2 or EC-2 with added submicron black carbon, fullerens or nanotubes instead of UDD.
EN
The analytical expression for the cross-spectral density function of stochastic electromagnetic Bessel–Gauss pulsed beams through a dispersive aperture lens is derived and used to study the changes in the spectral degree of polarization in an optical focus system. The changes in the spectral degree of polarization at the focal plane and on the z-axis are performed in the case of dispersion-free, dispersion of the first, second, and higher orders, respectively. It is shown that the dispersion affects the peak value of the spectral degree of polarization, and the higher order dispersion leads to a more obvious effect on the peak value of the spectral degree of polarization at the focal plane. On the z-axis, the spectral degree of polarization in the dispersion-free case is different form that in the dispersion case, however, the dispersion of different orders almost has the same effect on the spectral degree of polarization. The results obtained in this paper may be crucial for high precision laser detection.
EN
Several metal perchlorate complexes with 3(5)-hydrazino-4-amino- 1,2,4-triazole as a ligand were investigated. It was shown that the threshold of laser initiation of the copper complex changed under the influence of additives of optically transparent polymers, detonation nanodiamonds or nanotubes.
5
Content available remote Pulse interference detection in measurement systems
86%
EN
The paper presents an suboptimal algorithm of detection of interference pulses in industrial measurement devices and telecommunication systems which can be used for pulses excision. Performance characteristics of the detection procedure are obtained for interference pulse models with a different probability density functions of amplitude fluctuations.
PL
W artykule został przedstawiony suboptymalny algorytm detekcji zakłóceń impulsowych w przemysłowych systemach pomiarowych oraz w systemach telekomunikacyjnych który może być wykorzystany do eliminacji impulsów zakłóceń. Przedstawiono wybrane wyniki symulacji zaproponowanego algorytmu.
PL
Warystory ograniczników przepięć ulegają w trakcie eksploatacji procesom starzeniowym. Czynnikami narażenia są: napięcie robocze przemienne lub stałe, przepięcia, wyładowania niezupełne. Proces degradacji prowadzi do zwiększenia wydzielanej energii i tym samym do podwyższenia temperatury warystorów i wzrostu prądu przewodzenia. W pracy przedstawiono wyniki badań zmian degradacyjnych warystorów narażonych na oddziaływania udarowe. Warystory poddawane były oddziaływaniu serii impulsów, o liczbie zwiększanej w kolejnych etapach starzenia.
EN
The paper presents the effect of multiple impulse voltages on electrical properties of a zinc oxide (ZnO) varistor. The multiple impulse sequences were generated by a combination wave generator delivering a standard impulse voltage wave of 10/800 žs and, at the short-circuited output, a standard impulse current wave of 8/40 žs. Varistors were exposed to a series of impulses, repeated every 5 seconds, with a peak voltage value equal to five times value of the reference voltage. Changes in the voltage-current characteristics were measured at DC voltage supply. The measurements of these characteristics were taken immediately after the ageing process and then after 15 and 30 minutes since the end of pulse ageing. The durability of the observed ageing changes was studied using the additional measurement of the voltage-current characteristics after 65 hours since the completion of ageing. The test results show that the increase in the number of impulses in the series causes the visible reduction in the reference voltage U1mA. These changes are not of lasting nature - the reference voltage value grows with the time since the end of the aging and after a significant length of time (Fig. 2) reaches the value similar to that characterizing a new varistor (Fig. 1). The greater number of impulses in the series, the smaller reference voltage in the steady state, that is after ceasing the degradation process, as shown in Fig. 3. In this case, a longer time is needed to achieve the initial reference voltage U1mA. This means that the phenomenon of return is slower. The observed degradation and partial return to the initial varistor characteristics can be related to the processes of absorption and desorption of oxygen ions on grain boundaries [3, 4]. These ions are least connected with the varistor structure. In state of degradation and partial or total return to the initial state they are transported along the borders of ZnO grains and the intergranular phase.
7
Content available remote Influence of classic massage on blood pressure and pulse in 21-26 year olds
86%
PL
Praca przedstawia analizę oddziaływania masażu klasycznego na wartości ciśnienia tętniczego krwi i tętna u 10 zdrowych mężczyzn w wieku 21-26 lat. U każdego z badanych została wykonana seria 10 masaży, najpierw grzbietu, a później kończyny dolnej. Obie serie przedzielono kilkudniową przerwą. Przed i po każdym masażu u badanych dokonywano pomiaru ciśnienia tętniczego i tętna krwi. Z przeprowadzonych badań wynika, że wzrost czy spadek ciśnienia, jak również przyspieszenie czy zwolnienie akcji serca na skutek masażu są uzależnione od tego, która część ciała została poddana zabiegowi. Zanotowane zmiany nie są jednak statystycznie istotne.
EN
The paper presents an analysis of the impact of classic massage on blood pressure and pulse rate of 10 healthy males aged 21 to 26. Each of them received a series of ten massage sessions, first of their back, and then of their leg, with a few-day-long break between the two massage series. Before and after each massage the blood pressure and pulse rate of the examined were measured. The research results indicate that an increase or decrease of the blood pressure, as well as any changes of the pulse rate following a massage session, depend on the part of the body which has been subjected to the massage treatment. The changes observed are not statistically significant.
PL
Artykuł prezentuje analizę wartości pulsu człowieka w sytuacji wysiłku fizycznego oraz odpoczynku z podziałem na dwie grupy wiekowe oraz płeć. Pomiary wykonano przy użyciu aplikacji mobilnej oraz ciśnieniomierza nadgarstkowego. Badano dokładność pomiaru telefonem względem ciśnieniomierza oraz istotność statystyczną różnic pomiędzy grupami wiekowymi, płcią oraz wykonywaną czynnością. Niedokładność pomiarowa waha się od 4 do 12 %. Aplikacja mobilna dokładnej odwzorowuje puls podczas odpoczynku.
EN
The paper presents the analysis of the human heartbeat value under the physical exercise and rest condition. The test group was divided into four groups regarding age and sex. Measurements were performed using a mobile application and a blood pressure monitor. The phone's accuracy with respect to the blood pressure gauge was measured and the statistical significance of differences between age groups, sex and activity was also computed. Measurement inaccuracy varies from 4 to 12%. The mobile application accurately reproduces the pulse during rest.
9
Content available remote Identyfikacja częstotliwościowa parametrów fali tętna
86%
PL
Omówiono zastosowanie analizy częstotliwościowej do identyfikacji parametrów fotopletyzmogramu obwodowego. Opracowano metodę pomiaru częstotliwości podstawowej harmonicznej przebiegu PPG, opierającą się na badaniu korelacji obrazów. Zaprezentowano zastosowane sposoby cyfrowego kondycjonowania surowych przebiegów, uzyskanych w sposób prześwietleniowy przy użyciu czujnika napalcowego. Zaproponowano współczynnik zniekształceń przebiegu i przedstawiono algorytm jego wyznaczania.
EN
In the paper, an application of frequency analysis to identify of pulse waveform parameters is presented. The novel concept of the method for measurements of the fundamental frequency based on image correlation, and used means of conditioning a raw PPG signal acquired from a sensor, are described. The factor of nonharmonics disturbances (denoted as ), and an algorithm for its calculations have been defined. Some selected examples of real pulse waveforms and their factor are shown.
EN
BACKGROUND The aim of the study was to estimate the level of knowledge of normal heart rate in a randomly selected group of students of Kielce, Wrocław and Zielona Góra universities. MATERIALS AND METHODS The study was carried out in a group of 232 students (mean age: 23.14 ± 1.23 years), among which 37.5% (n = 87) students from Kielce participated, 29.7% (group II, n = 69) students from Wrocław, and 32.8% (group III, n = 76) students from Zielona Góra. In the study, a special questionnaire developed by the authors was used and it was filled in by the students anonymously. The questionnaire included questions on normal heart rates, pulse measurement skills, eating habits, diet, physical activity, use of stimulants, general health status, disease history, family anamnesis, and environmental data. RESULTS The range for normal values of pulse at rest was appropriately determined only by 19.4% of students. The knowledge of of pulse measuring techniques was demonstrated by 84.5% of the students in the study. The students of Wrocław universities were characterized by a significantly higher level of knowledge of techniques of taking pulse measurements in comparison to the students from Kielce. The participants from Wrocław significantly more frequently correctly estimated the lower ranges of pulse and normal ranges of heart rates than their counterparts from Zielona Góra. CONCLUSIONS The knowledge of normal values of heart rates in randomly selected students of Kielce, Wrocław and Zielona Gora universities is insufficient and corresponds to an unsatisfactory level of knowledge of the whole population on cardiovascular diseases and their risk factors.
PL
WSTĘP Celem badania było określenie znajomości prawidłowych wartości tętna w wybranej losowo grupie studentów z Kielc, Wrocławia i Zielonej Góry. MATERIAŁ I METODY Badanie przeprowadzono w grupie 232 studentów (średnia wieku: 23,14 ± 1,23 roku), w tym 87 z Kielc (37,5%, grupa I), 69 z Wrocławia (29,7%, grupa II), oraz 76 z Zielonej Góry (32,8%, grupa III). W projekcie posłużono się opracowaną przez zespół autorów ankietą, wypełnianą przez badanych anonimowo. Ankieta zawierała pytania dotyczące wiedzy na temat prawidłowych wartości tętna, umiejętności jego pomiaru, nawyków żywieniowych, stosowania diety, aktywności fizycznej, stosowania używek, obecnego stanu zdrowia, przeszłości chorobowej, wywiadu rodzinnego i środowiskowego. WYNIKI Zakres wartości normatywnych tętna w spoczynku prawidłowo określiło jedynie 19,4% studentów, znajomość techniki pomiaru tętna deklarowało 84,5%. Osoby studiujące we Wrocławiu w porównaniu ze studiującymi w Kielcach charakteryzowały się istotnie statystycznie większą deklarowaną znajomością techniki pomiaru tętna, a także – w porównaniu ze studentami z Zielonej Góry – znamiennie częściej prawidłowo określały najniższą, jeszcze prawidłową wartość tętna oraz zakres jego wartości normatywnych. WNIOSKI Znajomość prawidłowych wartości tętna w wybranej losowo grupie studentów z Kielc, Wrocławia i Zielonej Góry jest niewystarczająca i wpisuje się w niezadowalający obraz wiedzy ogółu społeczeństwa na ten temat.
PL
W artykule opisano metodę wyznaczania rozkładu przestrzennego indukcji pola magnetycznego i natężenia pola elektrycznego, które są wytwarzane przez relatywistyczne wiązki cząstek naładowanych. Opisaną metodę zastosowano do wyznaczania rozkładów tych pól w otoczeniu paczki protonów przyspieszanych w LHC. Wykazano, że takie paczki wytwarzają silne impulsowe pola magnetyczne o indukcji od kilkuset do kilkudziesięciu T w obszarze o rozmiarach kilku cm. Pola te mogą być z powodzeniem wykorzystane do badana właściwości materiałów w nowej, dotychczas nie osiągalnej skali przedziałów czasu rzędu fs.
EN
The estimation method of the spatial distribution of the magnetic field induction and the electric field intensity which are produced by a relativistic beam of charged particles is described in this paper. The described method is applied to estimation of this fields distribution in surroundings of protons bunch which are accelerated in the LHC. It is demonstrate, that such bunches producing of the pulsed high magnetic field with induction from a few hundred to a few dozen of T in space of dimension of a few cm. The fields are responsive for successfully application to research of a materials properties in a time interval of fs order, which are not available earlier.
EN
Extremely hard materials can be easily machined by Electrical Discharge Machining process due to its thermal erosion nature. In this process, the amount of material removed is directly proportional to the discharge current. Due to the stochastic nature of the thermal erosion process, the discharge current is varied for every applied electrical pulse. It results in different levels of material removal over the material surface during machining process. The volume of the crater is determined by the discharging energy. The variation in the discharging energy produces high surface roughness, which is influenced by discharge current. A constant duration discharge current is needed throughout the process to produce better surface quality. In this research, an iso duration current pulse generator has been proposed to achieve good surface finish. An experimental performance evaluation has been conducted with conventional transistor pulse train generator and modified iso current pulse generator by Taguchi L27 orthogonal array design. The machining characteristics have been evaluated for both the pulse generators. It is found the that modified iso duration current pulse generator has produced better surface quality with higher material removal rate than the conventional transistor pulse train generator.
PL
Artykuł dotyczy problemów związanych z wysokoenergetycznym środowiskiem elektromagnetycznym. W artykule scharakteryzowano impuls elektromagnetyczny wielkiej mocy oraz omówiono stanowisko do generowania takich impulsów i stanowisko do ich pomiarów. Główną uwagę poświęcono sondom pomiarowym D-dot do pomiaru impulsowego pola elektromagnetycznego. Ponadto w artykule przedstawiono metodę walidacji sondy pomiarowej Ddot z wykorzystaniem impulsów HPM.
EN
The article concerns the problems of high-energy electromagnetic environment. The article characterizes the high-power electromagnetic pulse and discusses the laboratory stand for generating and measurements such impulses. The main attention was devoted to the D-dot measuring probes for measuring the pulsed electromagnetic field. Moreover, the article presents the method of validation of the D-dot measuring probe with the use of HPM pulses.
14
Content available remote Udary przepięciowe w obwodach elektroenergetycznych niskiego napięcia
72%
PL
Opisano przebiegi i parametry przepięć występujących w obwodach zasilania elektroenergetycznego niskiego napięcia. Dokonano przeglądu znormalizowanych impulsów, który oparto głównie na normach IEEE oraz IEC. Przedstawiono główne podobieństwa i różnice koncepcji dotyczących klasyfikacji źródeł narażeń, miejsc narażeń oraz środków ochrony przed przepięciami.
EN
Waveforms and parameters of surges occurring in the low voltage power circuits are described. A review of standardized pulses is done, which is based primarily on the IEEE and IEC standards. The main similarities and differences in concepts regarding the classification of threat sources, places of occurrence, and measures for protection against surges are presented.
15
Content available remote Sterowany elektromagnetycznie pulsator akustyczny
72%
PL
W artykule opisano budowę układu do wytwarzania powtarzalnych impulsów fali akustycznej o częstotliwości 170-1840 Hz i czasie trwania 3.5 ms. Układ zawiera cylindryczny rezonator, którego jeden koniec zamykany jest migawką z otworem, sterowaną za pomocą elektromagnesów. Drugi koniec rezonatora został połączony z głośnikiem elektrodynamicznym, który wytwarza w rezonatorze falę stojącą. Natężenie tej fali wzrasta do ustalonej wartości w wyniku odbić od końców rezonatora i konstruktywnej interferencji. Po osiągnięciu tej wartości migawka otwiera rezonator. Wtedy fala stojąca zostaje przekształcona w falę bieżącą o zwiększonym natężeniu i wyemitowana z rezonatora. Podane zostały wyniki badań zależności natężenia emitowanej fali, współczynników wzmocnienia i sprawności układu w zależności od częstotliwości fali. Otrzymane wyniki zostały przedyskutowane i porównane z modelem teoretycznym, sformułowanym do opisu działania tego układu.
EN
The article describes construction of a system for production of repeatable pulses of an acoustic wave with a frequency of 170-1840 Hz and duration of 3.5 ms. The system includes a cylindrical resonator, one end of which is closed by a shutter with an aperture, controlled with electromagnets. The other end of the resonator was connected to an electrodynamics loudspeaker which produces a standing wave in the resonator. This wave intensity increases to the set value as a result of reflections from the ends of the resonator and some constructive interference. Upon reaching this value, the shutter opens the resonator. This is when the standing wave becomes transformed into a traveling wave of increased intensity, and afterwards emitted from the resonator. There are tests results presented which are related to intensity of the emitted wave, amplification factors and efficiency of the system, depending on the wave frequency. The obtained results were discussed and compared with a theoretical model, developed for description of operation of the system in question.
PL
Józef Struś (1510-1568) był jednym z najsławniejszych lekarzy europejskiego renesansu. Stał się szczególnie znany z powodu biegłości w zakresie krytycznej analizy dzieł Galena oraz badań nad układem krążenia. Dostrzegał zależności pomiędzy tętnem, pracą serca oraz przemianami metabolicznymi. Struś jest pierwszym naukowcem w dziejach medycyny europejskiej, który przedstawił tętno w formie diagramów oraz zastosował w praktyce ideę wykrywacza kłamstw.
EN
Józef Struś (1510-1568) was one of the most famous physicians of the European Renaissance. He became famous for his critical analysis of Galen’s works and his own research on blood circulation. He saw relationships between the pulse, heartbeat and the metabolism of the body. Struś was the first scientist in the history of European medicine to present the pulse in a diagram form and introduce the idea of a polygraph in practice.
EN
During natural contractions of a muscle, motor units (MUs) are activated by irregular discharge patterns of motoneurones. The aim of this study was to analyze changes in contractile forces of MUs following patterns of stimulation at variable frequency. Experiments were performed on 33 functionally isolated MUs of the fast-type in the medial gastrocnemius (MG) muscle of adult Wistar rats, under pentobarbital anaesthesia. The MUs forces evoked at five different regular stimulation patterns of constant frequencies were compared to forces generated during five random patterns of irregular stimulation with the same mean values of interpulse intervals, between 10 and 75 ms, and variability of these intervals of ± 50% in each case. These values cover the natural range of the preferred firing rates of the MG motoneurones from unfused to nearly fused tetanic contractions. Analysis of changes in tetanic forces indicated a linear relationship between the interpulse interval as well as the initial level of the force and the amplitude of the force increase of the next contraction. It was demonstrated that variability of the instantaneous tetanic force during the irregular discharge pattern depends on the level of tetanic fusion. Moreover, it was demonstrated that for low and moderately-fused tetani, effectiveness of a MU contraction (expressed as the force-time area) is considerably higher for contractions evoked by irregular stimulation patterns. On the basis of the results of this study it was supposed that during voluntary contractions, the influence of changes in the motoneuronal firing rate on the motor unit force depends on the initial level of force.
18
72%
|
1994
|
tom 08
|
nr 4
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.