Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Ograniczanie wyników
Czasopisma help
Lata help
Autorzy help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 88

Liczba wyników na stronie
first rewind previous Strona / 5 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  power systems
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 5 next fast forward last
EN
The types of dredgers classified in accordance with their modes of operation are shortly described in the paper. Design solution of power systems of trailing suction hopper dredgers, the most popular dredger type, are discussed and evalueted. Working conditions of the power systems are described on the basis of investigations of the dredger "Inż. St. Łęgowski" in operation.
PL
Podstawę monografii stanowią zagadnienia modelowania systemu elektroenergetycznego dla wyzna- czania stanów zakłóceniowych w oparciu o wyniki i doświadczenia uzyskane podczas tworzenia programów komputerowych dla symulatora sieci elektroenerge- tycznych "SYMEL" i dla SCADA systemu o nazwie "PRINS". W rozprawie zaprezentowano model matematyczny systemu elektroenerge- tycznego do obliczania wielkości zwarciowych w oparciu o metodę potencjałów węzłowych, przy czym model ten umożliwia obliczanie dowolnych zwarć zarówno w sieci ze skutecznie jak i nieskutecznie uziemionym punktem neutralnym. Do tego głównego zagadnienia włączono następujące dodatkowe problemy: . Metodę eliminacji impedancji ziemi, . Metodę uwzględniania rzeczywistych przekładni transformatorów w modelu matematycznym systemu elektroenergetycznego- . Zestawienie schematów zastępczych gałęzi systemu elektroenergetycz- nego wraz z ich impedancjami, przy założeniu że schemat zastępczy gałęzi dla składowej zgodnej i zerowej jest identyczny . Obliczanie impedancji gałęzi systemu elektroenergetycznego w oparciu o znane wielkości zwarciowe. . Sposób wyznaczania macierzy impedancyjnej węzłowej rozpatrywa- nej sieci elektroenergetycznej podzielonej na pewną ilość niezależ- nych podsieci, tzn. niepołączonych z sobą po podziale, ale takich, że każda z podsieci posiada połączenie z węzłem odniesienia. Macierz impedancyjną węzłową całej sieci oblicza się w oparciu macierze impedancyjne węzłowe każdej podsieci. . W oparciu o literaturę omówiono metodę obliczania prądów i napięć podczas dowolnego zwarcia występującego w linii napowietrznej lub kablowej bez konieczności wprowadzania nowego węzła. Druga część rozprawy jest poświęco- na metodologii modelowania systemu elektroenergetycznego do obliczania wielkości zakłóceniowych podczas dowolnego zakłócenia wielokrotnego. Opisano uogólniony model matematyczny systemu elektroenergetycznego do obliczania dowolnej kombinacji zwarć i przerw . Model ten wykorzystuje jedynie macierz impedancyjną węzłową sieci elektroenergetycznej, model matematyczny warunków brzegowych zakłócenia wielokrotnego, sposób modelowania fazy zakłócenia, metodę uwzględniania przekładni transforma- torów i metodę wyznaczania macierzy obrotu. Innym istotnym zagadnieniem omówionym w tej rozprawie jest proces redukcji węzłów w modelu matematycznym systemu elektroenergetycznego wykorzystu- jący fragment metody odwracania macierzy, tzn. proces rozkładu macierzy admitancyjnej na podmacierze. Ostatnim rozważanym problemem jest odwracanie macierzy admitancyjnej węzłowej sieci elektroenergetycznej, w tym przede wszystkim zaprezento- wanie sposobu zapamiętywania macierzy admitancyjnej oraz omówienie metody odwracania macierzy admitancyjnej niesymetry- cznej wykorzystującej metodę wektorów rzadkich. Wnioski i uwagi, wynikające z rozważanych w pracy zagadnień szczegółowych dotyczących modelowania systemu elektroenerge- tycznego dla obliczania stanów zakłóceniowych, zamieszczono w ostatnim rozdziale.
EN
The dissertation deal with the issues of power system modelling aimed to calculate fault states and is based on the results and own experience gained while designing software for the SYMEL electrical network simulator and for the PRINS system (a SCADA-type system). The work presents a power system mathematical model for calculating fault quantities on the basis of the node equation method, however, the presented model enables calculation of any short-circuit currents in electrical networks with both solidly and non-solidly earthed neutral. This main subject also includes the following additional issues: . The earth impedance elimination method. . The method of taking into account actual transformer ratios in the analysed mathematical model. . Presentation of power system branch equivalent circuits together with their impedances assuming that the branch equivalent circuits for the positive and zero components are identical. . Calculation of the power system branch impedance on the basis of the obtained short-circuit quantities. . The way of calculating the node impedance matrix of the analysed electrical network divided into different independent subnetworks, i.e. subnetworks which are not interconnected but each of them is linked with the reference node. The node impedance matrix for the whole network is calculated on the basis of node impedance matrices of each subnetwork. . The well-known method of calculating currents and voltages duńng any short circuit occurring in an overhead or cable line without having to introduce a new node. The second part of the dissertation is devoted to the methodology of power system modelling used for calculating fault quantities during any multiple faults. It describes a general power system mathematical model used for calculating any combination of short circuits and breaks. This model uses: the node impedance matrix of an electrical network, a mathematical model of the initial conditions of a multiple fault, a mathematical model of the phase with a fault, the method of taking into account transformer ratios and the method of calculating the rotation matrix. Another significant issue analysed in the dissertation is the process of node reduction in the power system mathematical model which uses a part of the matrix inversion method (i.e. the part concerning factorisation of the admittance matrix). Finally the dissertation analyses the inversion of the node admittance matrix of an electrical network, focusing most of all on the presentation of the admittance matrix storing method and the asymmetrical admittance matrix inversion method using the sparse vector method. Conclusions and comments resulting from the analysed issues concerning power system modelling for calculating fault states are presented in the last chapter .
3
Content available Regulacja grupowa w systemie elektroenergetycznym
80%
PL
W węzłach wytwórczych i przesyłowych w celu zapewnienia prawidłowego procesu regulacji napięć i sterowania rozpływem mocy biernej w systemie należy dążyć do zastosowania układów regulacji grupowej napięcia i mocy biernej. Układ regulacji grupowej powinny swoim sterowaniem (nadrzędnym) obejmować wszystkie ukałdy regulacji biorące udział w procesie regulacji U i Q w danym węźle. W referacie przedstawiono wymagania dla układów regulacji grupowej w węzłach wytwórczych i przesyłowych systemu elektroenergetycznego.
EN
In generating and transmission nodes to secura for the grid correct process of voltage regulation and reactive power flow control it is needed to aim at application the systems of group regulation on voltage and reactive power. Systems of group regulation by its superior control should overcome all regulation formations whose take a part in the process of U & Q regulation in particular. In the paper requirements for the systems of groupregulation in generating and transmission nodes have been proposed.
EN
This paper presents proposed developments of a new formulation and a full algorithm for transient detection by applying Parks transformation. This approach consist in transforming three-phase voltage or current signals into Parks components known as direct, quadrature, and zero axes components. The input signals are local measurements of a power transmission or distribution system. Then, transients are superimposed in three-phase signals that can be detected in Parks components through the finite difference between samples. A full algorithm for the transient detection is presented and envisions the possibility of being applied in real time. In order to demonstrate the proposed algorithms performance, four case studies are considered: capacitor energizing, distribution transformer energizing, permanent resistive fault, and high impedance fault. These cases were simulated on a typical Brazilian sub-transmission line using Alternative Transient Program. As demonstrated by the case studies, the proposed formulation introduces further improvements for transient detection in power systems.
PL
Artykuł zawiera zagadnienia związane z optymalizacją wyboru urządzeń elektrycznych podczas prac remontowych lub modernizacyjnych okrętowego systemu elektroenergetycznego. Wybór tych urządzeń w warunkach rynkowych powinien być efektywny technicznie i ekonomicznie. Rezultatem powinien być wybór optymalny.
EN
High exploitation costs make the rational use of energy necessary. Problems with multicriteria of the device choice are presented in this article during modernization or repair electrical ship system. The final result should be the optimal choice.
6
Content available remote Wpływ elektrowni wiatrowych na system elektroenergetyczny
80%
PL
W artykule omówiono problemy związane z rozwojem systemów elektroenergetycznych, w tym związane z rozwojem elektroenergetyki wiatrowej i jej wpływem na system elektroenergetyczny. Omówiono oddziaływanie elektrowni wiatrowych na różne elementy funkcjonowania systemów elektroenergetycznych..
EN
The paper discusses the problems associated with the development of power systems with high penetration of the renewable sources of energy like the wind turbines. There is considered its impact on the power system regarding various effects of the wind farms influence on the grid operation
8
Content available remote Technological features of gliding arc discharges plasma
80%
EN
Investigations presented in the paper show that the kind of plasma gas, its composition and flow rate strongly influence operational characteristics of the power supply system and courses of voltage and instantaneous power. On the basis of researches presented in the paper the direction how to design industrial installations of multielectrode gliding arc reactor power systems accordingly to the requirements of the plasma-chemical process can be formulated.
PL
Przedstawione w pracy badania pokazują, że rodzaj, skład i prędkość przepływu gazu istotnie wpływają na charakterystyki pracy oraz przebiegi napięć i mocy reaktora plazmowego ze ślizgającym się wyładowaniem łukowym. Wyniki badań posłużą do projektowania i budowy przemysłowych instalacji wieloelektrodowych reaktorów plazmowych ze ślizgającym się wyładowaniem łukowym, jako technologicznych źródeł plazmy.
EN
In this paper, a discrete wavelet transform (DWT) based approach is proposed for power system frequency estimation. Unlike the existing frequency estimators mainly used for power system monitoring and control, the proposed approach is developed for fundamental frequency estimation in the field of energy metering of nonlinear loads. The characteristics of a nonlinear load is that the power signal is heavily distorted, composed of harmonics, inter-harmonics and corrupted by noise. The main idea is to predetermine a series of frequency points, and the mean value of two frequency points nearest to the power system frequency is accepted as the approximate solution. Firstly the input signal is modulated with a series of modulating signals, whose frequencies are those frequency points. Then the modulated signals are decomposed into individual frequency bands using DWT, and differences between the maximum and minimum wavelet coefficients in the lowest frequency band are calculated. Similarities among power system frequency and those frequency points are judged by the differences. Simulation results have proven high immunity to noise, harmonic and inter-harmonic interferences. The proposed method is applicable for real-time power system frequency estimation for electric energy measurement of nonlinear loads.
EN
The safety of transport facilities depends not only on effectiveness of the applied individual safety systems but also on their power supply systems’ proper operation (also including electromagnetic interferences). Therefore, in this paper, the authors analysed the power supply selection for the electronic safety systems applied in transport, taking into account the reliability and exploitation requirements included in the regulations and standards on these systems. The appropriate electricity supply to electric safety systems is the basis of their proper functioning. It means that the power supply, with required parameters for a given device, should be connected to individual electric receivers of electric safety systems. However, only supplying electricity to the device is not equivalent to provision of its operation continuity and the appropriate level of values of the reliability and exploitation indices. Therefore, emergency power supply systems should be used. The authors developed an algorithm of the power supply selection for electronic safety systems, including the categories of power and hazards occurring in the facility. In further considerations, it is planned to carry out further analyses taking into account other types of power supply systems, and the development of a computer programme, which constitutes an exemplification of the obtained deliberations.
PL
Przedstawiono schemat blokowy typowego zasilania potrzeb własnych oraz nową propozycję układu, zbudowanego z wykorzystaniem ogniwa paliwowego.
EN
The paper presents błock diagram of typical auxiliary on-site power system and a new proposal of the system, based on fuel celi.
EN
In this paper, we apply the heuristic method for determination of control functions for controllability analysis of nonlinear power systems. The problem of control of quasi-linear systems under proper assumptions on the nonlinear term is considered in the general statement. Making use of the Green’s function solution of nonlinear systems, the exact and approximate controllability conditions are expressed in terms of unknown controls in an explicit form. The way of resolving controls determination is discussed. As a particular application, a one-machine infinite-bus system is considered described by a coupled system of three first order ordinary differential equations. Two heuristic forms of admissible controls are considered providing approximate controllability within the same amount of time having different intensities. Results of numerical simulations are presented and discussed.
PL
W artykule przedstawiono przegląd opracowanych w Instytucie Metrologii Elektrycznej i wdrożonych do produkcjiw OBRME METROL w Zielonej Górze przyrządów pomiarowych przeznaczonych do pomiaru parametrów sieci energetycznych i oceny jakości energii elektrycznej. Przedstawiono metody przetwarzania i strukturę przyrządów. Omówiono modele matematyczne obwodów wejściowych, przedstawiono wyniki badań oraz metodę korekcji błędów wnoszonych przez obwody wejściowe.
EN
Sampling instruments capable of measuring multiple electrical parameters in three phase systems are presented in this paper. A software method of correcting an errors that are introduced by measuring transformers on power measurements accuracy with distorted signals also is presents. The method has been implemented in sampling of power meters. result of the method also are shown.
14
70%
PL
Morskie systemy energetyczne, które pozwolą zapewnić wysoką jakość zasilania, będą oparte głównie na wysokonapięciowych i stałoprądowych sieciach przesyłowych HVDC. Nadal brakuje praktycznego doświadczenia do optymalnej pracy i regulacji tych złożonych systemów i ich wpływu na zarządzanie równolegle połączonych sieci AC. Nowe koncepty muszą być opracowywane i testowane, zarówno w zakresie technologii (urządzenia pomiarowe i sterowania), jak i aplikacji (symulacyjne i wizualizacyjne). Zadaniem projektu "Sea Power Grid-Secure", finansowanego prze niemieckie ministerstwo ochrony środowiska, jest badanie niezawodności takich systemów, ich sposobów regulacji, obserwowalności, a także zabezpieczenia. Autorzy – oprócz opisu projektu – zawarli w tekście interesujące podsumowanie jego pierwszych wyników.
EN
Wind farms in the North Sea are expected to play a key role in supplying electricity to Europe in the nearest future. Therefore the issue of reliability and control of Offshore Wind Power Systems is of primary importance for the Interconnected Network of ENTSO-E in Europe and its operational safety. All the EU states need a high-quality electricity supply to meet the demands of large industrial customers. The Offshore Wind Power Systems, which will ensure high-quality supply, are designed to be based on the HVDC technology. However, we are still lacking experience to ensure optimal operation and control these complex systems and their impact on the management of interconnected AC grids. Therefore new ideas and concepts have to be developed and tested in the area of technology (measuring and control systems) and application (simulation and visualization). One of them is the project called "Sea Power Grid-Secure", financed by the German Ministry of Environment Protection, aimed to test the reliability, control, observability and security of such systems. The paper provides a description of the project and summary of its initial results.
EN
Multiple input multiple output power line communication is presented with its major characteristics and models. Orthogonal frequency division multiplexing modulation scheme applied to power line channel model is presented, also, combination of orthogonal frequency division multiplexing with MIMO Alamouti space time block codes to improve reliability and data rate performance of the system is done. The evaluation of the orthogonal frequency division multiplexing-PLC system over power line communication channel is performed. The comparison between simple PLC and MIMO-PLC systems based upon achieved data rates and reliability in terms of bit error rate is presented.
EN
Verification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5-20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits with RCDs usually use an extremely low value of current (lower than 15 mA), which in many cases it is not acceptable in terms of the measurement accuracy. This paper presents a method of earth fault loop impedance measurement in 3-phase circuits, without nuisance tripping of RCDs – the concept of measurement, the meter structure and the experimental validation. The nuisance tripping is avoided in spite of the use of measuring current value many times higher than that of the rated residual current of RCDs. The main advantage of the proposed method is the possibility of creating values of measuring current in a very wide range, what is very important with regard to accuracy of the measurement.
PL
W niniejszym referacie zaprezentowano wyniki badań dotyczących oceny wykorzystania stacji przekształtnikowych łącza HVDC do kompensacji mocy biernej w systemie elektroenergetycznym. Poprzez odpowiednie sterowanie kątem zapłonu w przekształtnikach można wpłynąć na wartość mocy biernej pobieranej przez ten przekształtnik. Dołączając do tego sterowanie przekładnią transformatora przekształtnika, uzyskuje się układ, w którym można zachować stały przepływ mocy czynnej przy zmieniającej się wartości mocy biernej. Teoretycznie, jeżeli połączy się sterowanie elementami do kompensacji mocy biernej, zainstalowanymi w stacji HVDC, ze sterowaniem pracy zespołu przekształtnika (przekształtnik + transformator), to w efekcie można uzyskać układ, który z powodzeniem można wykorzystać do kompensacji mocy biernej w systemie elektroenergetycznym. Wykonane badania wykazały, że można prowadzić regulację mocy biernej pobieranej przez przekształtniki łącza HVDC, uzyskując znaczące zakresy zmiany tej mocy przy zachowaniu stałej zadanej mocy czynnej przesyłanej tym łączem.
EN
Software power protection tester implemented in a real-time operating system (RTOS) might replace the conventional testing setups in IEC 61850 protection systems. This paper describes an open power protection testing platform. Linux RT capabilities related to runtime environment for such a tester are examined and OS latency sources are identified and evaluated. An algorithm for a multithreaded tester operation is proposed, including Sampled Values (SV) publisher, GOOSE input/output and time synchronization. SV and GOOSE services implemented in RT Linux environment are evaluated in accordance with IEC 61850‒5 transfer time requirements. Linux PTP time synchronization service of two similar systems controlling its electrical ports is evaluated in different synchronization scenarios. The developed tester is compared to an equivalent conventional setup during the test of IED over-current function. The conducted tests show that the Linux implementation of power protection tester in the case of scheduler latency, time synchronization accuracy and transfer time all meet the requirements of IEC 61850.
EN
Power system state estimation is a process of real-time online modeling of an electric power system. The estimation is performed with the application of a static model of the system and current measurements of electrical quantities that are encumbered with an error. Usually, a model of the estimated system is also encumbered with an uncertainty, especially power line resistances that depend on the temperature of conductors. At present, a considerable development of technologies for dynamic power line rating can be observed. Typically, devices for dynamic line rating are installed directly on the conductors and measure basic electric parameters such as the current and voltage as well as non-electric ones as the surface temperature of conductors, their expansion, stress or the conductor sag angle relative to the plumb line. The objective of this paper is to present a method for power system state estimation that uses temperature measurements of overhead line conductors as supplementary measurements that enhance the model quality and thereby the estimation accuracy. Power system state estimation is presented together with a method of using the temperature measurements of power line conductors for updating the static power system model in the state estimation process. The results obtained with that method have been analyzed based on the estimation calculations performed for an example system - with and without taking into account the conductor temperature measurements. The final part of the article includes conclusions and suggestions for the further research.
EN
The report brings solutions for selected failure conditions of turbogenerators in power plants. From the point of view of the stability of the power system (PS), the loss of excitation and the following drop-out of these turbogenerators belong to significant failure conditions of turbogenerators of high unit power. The electric protections of turbogenerators play an important role in systematic failure elimination [2], [14]. A complex solution of the protecting system of the most important devices of power plants (turbine, alternator, block transformer) taking into account various operation states faces a problem of dealing with the protection system at forbidden frequencies [9]. The frequency or angular velocity is one of important parameters of operation of the PS [10]. At transition processes the frequency of voltage in PS affects not only the frequency of the fault current but its magnitude as well. An increase in angular velocity has also a negative effect on the static and dynamic stability of PS. The paper presents a calculation of the setting and selectivity of selected turbogenerator protections.
first rewind previous Strona / 5 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.