In this paper, we make an attempt to use the QHY174M-GPS camera for the photometry research of fast-rotating artificial objects including debris, satellites and rocket bodies. This device is useful for imaging occultations, eclipses, meteors, and so on due to a highly precise recording of the time (GPS-based) and location of the observation on every frame and fast readout of the CMOS detector. The precision of time registration by the QHY174M-GPS camera is at the level of microseconds. All light curves obtained by studied camera during observations of artificial satellites in this work were carried out at Derenivka Observatory of Uzhhorod National University, Ukraine. The created photometric system with QHY174M-GPS camera as the detector and reflector telescope with parameters D=120 mm, F=114 mm, FOV=2.82°×1.76° was calibrated. For target observations, SharpCap software was used. For the purposes of photometry processing, ccd_phot software was developed using Python 3.8 programming language with astropy and photutils packages. Photometry observations of artificial satellites of the Earth and standard stars were carried out. Over 80 lightcurves of artificial satellites were obtained. Comparing synchronous observations from two sites, separated 15 km from each other, we can conclude that photometry on the QHY174M-GPS camera gave us the same shape of lightcurve and additional advantages, such as time of exposure or simplicity of usage.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Podstawowe wymagania stawiane bezkierunkowym lampom do użytku domowego zawarte są w rozporządzeniach Komisji Wspólnoty Europejskiej. Zwykle jednak weryfikacji podlegają tylko parametry początkowe. Parametry eksploatacyjne, ze względu na długi czas trwania pomiarów, nie są każdorazowo kontrolowane. W artykule zaprezentowano wyniki badań parametrów początkowych oraz współczynnika utrzymania strumienia świetlnego, po określonym czasie eksploatacji, wybranych bezkierunkowych lamp do użytku domowego.
EN
The basic requirements for non-directional household lamps are set out in Commission Regulations of the European Community. Usually only the initial parameters are verified. Operational parameters, due to the long duration of measurements, are not always controlled. The article presents the results of the initial parameters and lamp lumen maintenance factor, after a specified operational time, of selected non-directional household lamps
W artykule opisano wyniki badań, na podstawie których wyznaczono i oceniono podstawowe parametry fotometryczne, kolorymetryczne i elektryczne wybranych, ogólnodostępnych źródeł światła, które były zamiennikami tradycyjnej żarówki o mocy 60 W. Zbadano jedną żarówkę halogenową, trzy świetlówki kompaktowe oraz jedenaście źródeł LED. Generalnie stwierdzono, że w większości przypadków, zwłaszcza źródeł markowych producentów, parametry zmierzone i obliczone w niewielkim stopniu różnią się do deklarowanych przez producentów. Najkorzystniejszym zamiennikiem żarówek tradycyjnych są źródła LED, zarówno ze względu na swoje parametry użytkowe, jak i cenę, porównywalną z ceną świetlówek kompaktowych, a w niektórych przypadkach nawet niższą.
EN
This article presents test results. which were used in defining and evaluating basic photometric, colorimetric and electric parameters of selected, widely available light sources equivalent to a traditional incandescent 60-Watt light bulb. One halogen light bulb, three compact fluorescent lamps and eleven LED light sources were tested. In most cases (in brand name products, in particular) the measured and calculated parameters differ from values declared by manufacturers only to a small degree LED sources prove to be the most beneficial substitute for traditional light bulbs, considering both their operational parameters and their price, which is comparable with the price of compact fluorescent lamps or, in some instances, even lower light sources for households, photometric.
The article describes test results that provided the ground to define and evaluate basic photometric, colorimetric and electric parameters of selected, widely available light sources, which are equivalent to a traditional incandescent 60-Watt light bulb. Overall, one halogen light bulb, three compact fluorescent lamps and eleven LED light sources were tested. In general, it was concluded that in most cases (branded products, in particular) the measured and calculated parameters differ from the values declared by manufacturers only to a small degree. LED sources prove to be the most beneficial substitute for traditional light bulbs, considering both their operational parameters and their price, which is comparable with the price of compact fluorescent lamps or, in some instances, even lower.
PL
W artykule opisano wyniki badań, na podstawie których wyznaczono i oceniono podstawowe parametry fotometryczne, kolorymetryczne i elektryczne wybranych, ogólnodostępnych, źródeł światła, które były zamiennikami tradycyjnej żarówki o mocy 60 W. Zbadano jedną żarówkę halogenową, trzy świetlówki kompaktowe oraz jedenaście źródeł LED. Generalnie stwierdzono, ze w większości przypadków, zwłaszcza źródeł markowych producentów, parametry zmierzone i obliczone w niewielkim stopniu różnią się do deklarowanych przez producentów. Najkorzystniejszym zamiennikiem żarówek tradycyjnych są źródła LED, zarówno ze względu na swoje parametry użytkowe jak i cenę, porównywalną z ceną świetlówek kompaktowych, a w niektórych przypadkach nawet niższą.