EN
The influence of an extended grounding system on the dimensioning of an SPD system for apparatus protection against lightning surges is investigated. In an extended earthing arrangement, an apparatus distant from the main switch board is usually protected by an SPD system consisting of a first SPD at the main switch board (SPD1) and of a downstream SPD close the apparatus (SPD2); if the SPD2 is earthed locally, additional stresses on such SPD are expected due to lack of equipotentiality of the extended earthing arrangement. In this paper the current and the associated charge expected at installation point of SPD2 have been investigated by several computer simulations performed by means of the transient software EMTP-RV.
PL
W artykule rozważany jest wpływ systemu uziemienia na efektywność ochrony urządzeń, narażonych na oddziaływanie przepięć. Analizowany jest przypadek uziemienia kratowego i urządzenia oddalonego od głównej tablicy rozdzielczej, które zazwyczaj jest chronione przez system SPD składający się z: SPD w głównej tablicy rozdzielczej (SPD1) oraz SPD przy urządzeniu chronionym (SPD2). W sytuacji gdzie SPD2 jest uziemione lokalnie, występuje dodatkowe zagrożenie w związku z brakiem ekwipotencjalizacji układu uziemiającego. Przedstawione badania dotyczą spodziewanych wartości prądu i ładunku w punkcie instalacji SPD2, które zostały wykonane za pośrednictwem symulacji komputerowych przy użyciu programu EMTP-RV.
|
|
tom nr 4
CD-CD
PL
W artykule przedstawione zostały wybrane przebiegi napięć w kolejowej siecitrakcyjnej o napięciu znamionowym 3kV. Przebiegi zarejestrowane zostały podczas jazdy pociągu EN-57 z czoperowym układem napędowym oraz podczas postoju pojazdu. Przedstawiono wpływ pobieranego prądu przez pojazd szynowy na chwilowe wartości napięcia w kolejowej sieci zasilającej. Szczególną uwagę zwrócono na przebiegi prądu i napięcia zasilania pojazdu podczas przejazdu pod izolatorem dzielącym odcinki zasilania. Jest to bardzo niebezpieczny moment podczas jazdy pociągu, gdyż pojawiające się przepięcia i udary prądu negatywnie oddziaływają na sieć oraz na przekształtnik pojazdu.
EN
In the article, selected waveforms of the traction network voltage were introduced. The measurements were performed on train type EN-57. The nominal voltage network was 3kV and the waveforms were recorded during train operation and during stop. The influence of train power supply current to the voltage network was described in attached measurements. The tested train was equipped to DC drives with chopper currents regulators. The main aim of the article are descriptions of overvoltages and current surges during train operation at the power supplies section border, when train pantograph runs through the insulator, this is very dangerous moment of train operation. Appear overvoltages and current surges has negative influence to railway network and to train power converters.
3
Content available Symulacja zwarć transformatora przy działaniu SPZ
84%
PL
Transformatory pracujące w sieciach dystrybucyjnych najczęściej mają zabezpieczenie działające w cyklu SPZ. Rozpatrzono zwarcie bezpośrednie na uzwojeniu transformatora i zwarcie na kablu wyprowadzającym moc z transformatora. Przepięcia występujące przy wyłączeniu prądu zwarcia są kilka razy większe od napięcia znamionowego. Przy wyłączeniu zwarcia na kablu, oprócz przepięcia indukuje się składowa oscylacyjna napięcia o częstotliwości kilku kHz. Przepięcia rozkładają się nierównomiernie na poszczególnych zwojach. Największe przepięcia występują w zwojach leżących w strefie środkowej okna rdzenia. W czasie wyłączenia prądu zwarcia zwoje środkowe są najbardziej narażone na zwarcie zwojowe. Kolejne załączenie transformatora przy zwarciu zwojowym powoduje awarię.
EN
Transformers operating in distribution networks most often have protection operating in the AR cycle. A direct short-circuit on the transformer winding and a short-circuit on the cable leading the power out of the transformer were considered. The overvoltages occurring when the short-circuit current is switched off are several times higher than the rated voltage. When the short-circuit on the cable is cleared, in addition to the overvoltage, an oscillatory component of the voltage with a frequency of several kHz is induced. Overvoltages are distributed unevenly on individual turns. The highest overvoltages occur in the turns lying in the middle zone of the core window. During fault current interruption, the middle turns are most exposed to a turn-to-turn fault. Subsequent switching on of the transformer at a turn short circuit causes a failure.