Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  optical system
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Optical system for precise isocenter measurement
100%
EN
Introduction: The geometrical precision of the machines is essential for effective and safe radiotherapy. Methods currently used for the measurement of the mechanical isocenter have many limitations. In this work, the optical system NaviRation for very precise measurement of mechanical accelerator isocenter is described. The results of the measurement of the isocenter for linear accelerator are also presented. Materials and methods: An optical system for measuring the accelerator isocenter was designed and built. The optical system consists of two cameras recording the target position made according to a patented Zeiss technology. About 1,200 pairs of images are recorded during the rotation of the gantry, collimator and treatment table. Mathematical analysis of these images makes it possible to determine the location of the target center during rotation. In order to verify the accuracy of the measurements, a device simulating rotational motion was designed. The measurement results were also verified at the Central Office of Measures. The system must be calibrated each time before taking measurements. In this article, we present the results of measurements for the Versa HD accelerator. Results: The accuracy of determining the current position of the axis of rotation was 0.15 mm. The time of taking measurements of all rotations does not exceed 20 minutes. Measurement results for the Versa HD accelerator showed that this accelerator met the criteria described by TG142 of the AAPM. The diameter of the gantry, collimator and table isocenter spheres were 1.5 mm, 0.3 mm and 0.4 mm, respectively. Conclusions: The system enables precise, fast and simple mechanical isocenter measurement of the gantry, collimator and treatment table. It is also possible to perform all tests related to the measurements of distances, e.g. quality control of distance indicator, and distance of the table movement. The isocenter is measured independently of the accelerator for which measurements are made.
PL
Tematyka artykułu nawiązuje do szerszych badań prowadzonych nad zaprojektowaną optyczną głowicą skanująco-śledzącą przeznaczoną do przeciwlotniczych pocisków rakietowych bliskiego zasięgu samonaprowadzających się na cel metodą pasywną. Głowica poprzez układ wirujących zwierciadeł automatycznie skanuje przestrzeń. W chwili wykrycia celu na detektor podczerwieni układu optycznego głowicy pada promieniowanie emitowane przez cel. W artykule przeprowadzono badania dotyczące możliwości dokonywania programowej selekcji celu spośród wielu celów powietrznych wykrytych przez układ optyczny głowicy jeszcze przed startem pocisku rakietowego. Wybrane wyniki badań zaprezentowano w postaci graficznej.
EN
The issues discussed in this article refer to the wider-scope research on a software optical scan-track warhead designed for short range passive homing missiles. The warhead automatically scans the space ahead using a set of revolving mirrors. The moment it detects the target the rays emitted by the target fall on an infrared detector in the warhead optical system. This article presents studies on possibilities to make software selection of a target out of several air targets detected by the warhead optical system before the launch of the missile. Selected results of the studies are presented in graphic form.
EN
This paper presents optical and ultrasound excitation lock-in thermography systems for the detection of structural defects. Both systems can be used for the remote monitoring of thermal features like cracks, delaminations and other irregularities. The method consists of the excitation of thermal effects in a tested structure with the use of external heat or an ultrasound source. These effects result from propagation and reflection of thermal waves, which are input through the surface into the tested structure by absorption of modulated heat radiation or ultrasound waves.
PL
W pracy przedstawiono optyczny i ultradźwiekowy system termograficzny do wykrywania defektów strukturalnych. Obydwa z prezentowanych systemów poprzez monitorowanie termicznych parametrów struktury pozwalają wykryć pęknięcia, rozwarstwienia oraz inne nieciągłości materiału. Metoda polega na wywołaniu zmian rozkładu pola temperatury w miejscu występowania defektu poprzez zewnętrzne modulowane źródła ciepła (lampy halogenowe) lub ultradźwiękowe żródła energii.
4
Content available Komercyjne zastosowanie technologii CPV na świecie
63%
|
|
tom R. 22, nr 12
2511--2517, CD
PL
W artykule dokonano analizy aktualnego stanu wiedzy na temat technologii CPV, poprzez zbadanie jego statusu na rynku, w przemyśle oraz badaniach naukowych. Omówiono technologie ogniw fotowoltaicznych stosowanych w systemach CPV oraz układy optyczne służące do koncentracji promieniowania słonecznego. Przedstawiono przykłady funkcjonujących elektrowni wykorzystujących technologię koncentracji promieniowania słonecznego. Zaprezentowano całkowitą moc zainstalowanych na świecie elektrowni CPV oraz dokonano analizy kosztów inwestycyjnych. Oszacowano koszt produkcji energii elektrycznej w systemach CPV
EN
The article analyzes the current state of knowledge on the CPV technology by examining its status in the market, industry and research. Discusses the technology of photovoltaic cells used in CPV systems and optical systems used to concentrate solar radiation. The examples of operating plants using solar concentration technology were shown. The total power installed in the world CPV power plant was presented. The analysis of investment costs was shown. The electricity production cost in the CPV systems was estimated.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.