Przedstawiono wyniki analizy zmian jakości wody Wisły w przekroju ujęcia dla Warszawy w okresie 1980-1996, przeprowadzonej na podstawie średnich miesięcznych wartości stężeń 42 wskaźników zanieczyszczenia. Stwierdzono, że jakość wody w Wiśle w analizowanym przekroju nie odpowiada wymaganiom tak krajowych, jak i europejskich przepisów prawnych dotyczących wody ujmowanej do celów komunalnych.
EN
The paper presents results of the analysis of changes in the quality of the Vistula water in the cross-section of the water intake for Warsaw in the period 1980-1996, based on monthly average values of concentrations of 42 pollution indices. The Authors slate that the quality of the Vistula water in the analysed river cross-section does meet the requirements of Polish and European legal regulations concerning sources of drinking water.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Reasons for water corrosive properties, indicators used in estimating this feature and main phenomena taking place during corrosive water transportation. Electro-chemical corrosion of metals. Accepted parameters for cold waterwith lowered corrosive quality. Chemical corrosion of non-metal materials. Microorganisms growth.
3
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Jednym z warunków racjonalizacji zużycia ciepła geotermalnego jest stworzenie korzystnej wymiany ciepła pomiędzy wodą geotermalną i wodą sieciową. W sieciach ciepłowniczych wykorzystujących ciepło geotermalne istotnym jest, aby temperatura wody opuszczającej instalacje grzejne odbiorców była jak najniższa, tak by mogła determinować temperaturę zatłaczanej wody geotermalnej. Aby spełnić ten warunek, wskazane jest stosowanie głównie niskotemperaturowych odbiorników ciepła, lub przynajmniej łączenie odbiorców posiadających instalacje wysokotemperaturowe z odbiorcami wyposażonymi w instalacje niskotemperaturowe, co umożliwia bardziej efektywne schładzanie wody sieciowej. W pracy przedstawiono sposób oceny możliwości pozyskiwania i wykorzystania energii geotermalnej dla wybranych sieci cieplnych przy połączeniu dwóch grup odbiorników ciepła z zastosowaniem wymienników geotermalnych.
EN
One of the conditions for rationalisation of geothermal water use is to enable the most efficient heat transfer between geothermal water and municipal water. In district heating networks utilising geothermal heat it is important to bring the retum water temperature from the heat installations of recipients to the lowest level, so that it could determine the temperature of pumped geothermal water. In order to fulfil that condition it is advised to implement predominantly low-temperature heat receivers or at least combination of recipients having high temperature installations with recipients having low-temperature installations, which enables effective cooling of municipal water. In this paper has been presented the method of assessment the possibility of extraction and utilisation of geothermai energy for selected district heating networks at combination of two groups of heat receivers with application of geothermal water heat exchangers.
4
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The sewerage system is a vital component of all wastewater disposal structures. The architecture of buried municipal networks differs significantly depending on the considered city, local subsurface conditions and terrain configuration. History and characterization of sewerage system in Wroclaw which is gravitational with pressure elements (pumping stations, pressure sewers) has been presented. The total length of gravitational sewers equals to ca. 1700 km, including 1300 km combined and separate sanitary sewers as well as 400 km storm water sewers under administration of Wroclaw Municipal Water and Sewerage Systems Company only since 2010. The data about amount of wastewater and recorded failures of gravitational sewers in 2006-2008 have been collated and analyzed. The amount of wastes gathering by combined and separate sanitary sewers was equal to 43-47 million m3per year, and the average indicator of sewage effluent recalculated per one citizen of Wroclaw agglomeration equaled ca. 0.178 m3 per one day. On average per one month, the number of sewers' damages was in the range 7.3-8.3, and the average failure rate per one year and one kilometer of network length (without storm water sewers) equaled 0.07.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.