Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 9

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  modelowanie pożaru
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
2
Content available remote Oddziaływania na konstrukcje w warunkach pożaru wg PN-EN 1991-1-2
86%
EN
Ensuring a safe evacuation for the users of a building is a major goal when designing structures and systems protecting them against the effects of a fire. The article discusses the safety assessment for evacuation of users from a building exemplified by an analysis using computational fluid mechanics to reproduce the environmental conditions during a fire. It presents a way to evaluate the possibility of a safe evacuation of users from a facility by indicating the criteria for the assessment of conditions on the evacuation routes during emergency evacuation. In order to verify the criteria for assessing the evacuation safety, a three-dimensional model of the object under consideration has been prepared, for which a dedicated calculation solver of Fire Dynamic Simulator fluid mechanics has been used to recreate the fire conditions in the building. Prepared calculation model takes into account both the development of a fire on a given floor of the building and the simulation of the designed fire ventilation system in operation. In the paper the authors compare the assumptions used to create a calculation model and analyze their impact on the assessment of evacuation safety. Comparative analysis of the assumptions used to prepare the fire model allowed to draw conclusions particularly important for the people evaluating the evacuation safety on the basis of the analysis of the operation of fire ventilation systems using the computational fluids mechanics.
4
Content available Przegląd hybrydowych modeli pożaru
72%
|
|
tom Nr 4
79--92
PL
Cel: Celem niniejszego artykułu jest omówienie oraz ocena hybrydowych modeli pożaru, które zostały opracowane na świecie w ostatnich kilkudziesięciu latach. Wprowadzenie: Modelowanie pożarów przy użyciu komputera miało swój początek w latach 80-tych. Od tej pory aż do dzisiaj powstało kilkaset różnych modeli, poczynając od najprostszych integralnych poprzez strefowe do najbardziej złożonych polowych wykorzystujących technikę CFD (Computational Fluid Dynamics). Ze względu na bardzo długi czas obliczeń, jaki jest wymagany w przypadku modeli polowych (przy prostszych obiektach jest to średnio kilkadziesiąt godzin dla jednego scenariusza, przy bardziej złożonych nawet kilkaset), w końcu lat 90-tych zaczęto opracowywać koncepcję modeli, których dokładność byłaby znacznie większa niż modeli strefowych, natomiast czas obliczeń byłby istotnie krótszy. Takim przykładem mogą być hybrydowe modele pożaru. Metodologia: Artykuł zawiera podstawowe informacje na temat aktualnie dostępnych na świecie modeli hybrydowych. Omówiono w nim: model komórkowy Chowa wykorzystujący rozpowszechniony model strefowy CFAST, modele FASIT i FAS3D, które uwzględniają dodatkową warstwę mieszania, model wielowarstwowy Suzuki, w którym zastosowano podział pomieszczenia na n poziomych warstw o tej samej wysokości, model mieszany Hua wykorzystujący kombinację modeli strefowych i polowych. Biorąc pod uwagę ogólne wymagania, jakie powinny spełniać modele pożarów, w pracy zamieszczono ocenę poszczególnych modeli hybrydowych, a także próbę ich porównania ze sobą. Na końcu zamieszczono podsumowanie rozważań i kilka ogólnych wniosków z nich wynikających. Wnioski: Na podstawie przeprowadzonej oceny można stwierdzić, że obecnie istniejące modele hybrydowe nie są w stanie w pełni zastąpić modeli polowych opartych na technice CFD. Aby było to możliwe, należy jeszcze włożyć wiele pracy w ich rozwój, a w szczególności uwzględnić m.in. następujące zagadnienia: zmianę parametrów pożaru w każdej komórce, uniwersalny model gaszenia przy pomocy tryskaczy, dysz mgłowych lub prądownic, wpływ pożaru na konstrukcję budynku, możliwość wpływania użytkownika na dokładność otrzymanych wyników, a tym samym czas obliczeń, określenie bieżącego zapotrzebowania na tlen i wpływu jego stężenia na proces spalania oraz zastosowanie odpowiedniego modelu turbulencji.
EN
Purpose: The main purpose of this article is to describe and evaluate of hybrid fire models which have been developed all over the world in the last several decades. Introduction: Computer modeling of fires was introduced in the early eighties. Several hundred fire models have been created till now from the simplest integral to the most complex field one, using CFD (Computational Fluid Dynamics) technique. Field models require very long time for single simulation (the simpler objects need often about several dozen hours for simple scenario and even hundred hours for more complex scenarios). That was the main reason for appearance of a new idea in modeling of fires. Several hybrid models have been carried out in the end of nineties and in the beginning of this century. Its accuracy was comparable with field models, but time needed for single fire scenario was significantly shorter. Methodology: This article contains basic information on hybrid models and includes their evaluation. One of the first models was a result of work made by Charters and McIntosh on Leeds University (England), which effected in FASIT program created for studying of fires in tunnels and FAS 3D being a three-dimensional version of the first one (fires in compartments). CFD modeling elements were used in this program and each gas layer was divided into the grid of control volumes. For the first time, the mixing zone was separated into upper and lower zone. Obtained model has both main features of the field and zone models, what enables to simulate the gas fire environment in compartments more precisely than with the typical zone model without the need of performing long and expensive calculations. In turn, Chow proposed a method of using the existing CFAST tool for larger compartments. He divided the analyzed volume into several smaller cells (he examined cases with 3, 9 and 15 cells), and then, for each one of them he used the same approach as for single compartment. In 2002, Suzuki et al. proposed a modified multilayer model. He divided single compartments into horizontal layers with equal heights and determined the same parameters for each one of them using the equations following from mass and energy conservation laws. Another approach to the hybrid model was proposed by Hua et al. They used a combination of field and zone models to simulate and analyze the fire smoke propagation in multistorey building. It was assumed that in compartments with more complex fire dynamics, that is, i.e. with a fire source, the calculation mechanism would be consistent with the field model, while in compartments where the hot and cold zones are determined more clearly (i.e. corridors, compartments located farther from the fire source), the zone model should be used. Conclusions: Article presents several characteristics which show time curves of under-ceiling layer thickness achieved for the proposed model and for the typical zone and field models. Last of the mentioned solutions seems to be very interesting, but even in compartments with simpler fire dynamics where the zone model was used, unpredictable processes can occur (i.e. unsteady flows, local whirls). They can result in considerable spatial differences of calculated parameters, such as: temperatures, pressures, gas concentrations, etc. Based on the evaluation and comparison of discussed hybrid models one can claim, that neither of them doesn’t meet all requirements. There is still a lot of work that should be done on these models to improve them by consideration of the following aspects: changes of fire parameters in every cell, turbulence model, application of universal model of extinguishing systems including sprinklers, mist heads and nozzles, affecting of fire on building construction, possibility for user to influence on the calculation accuracy, determining of actual oxygen consumption and influence of different factors on combustion and pyrolysis process.
PL
W artykule przedstawiono opis wizualizacji dymu i płomieni w symulatorze do szkolenia i treningu wspomagającego dowodzenie podczas działań ratowniczych związanych z pożarami w budynkach wielokondygnacyjnych. Symulator taki od kilku lat jest na wyposażeniu Szkoły Głównej Służby Pożarniczej. Symulowany pożar miał miejsce w pomieszczeniu hotelowym. Przewidziano dwa przypadki konfiguracji otworów wentylacyjnych. W pierwszym z nich drzwi wyjściowe z pomieszczenia były zamknięte, w drugim – otwarte. Modelowanie podobnego pożaru przeprowadzono również w programie Fire Dynamics Simulator i dokonano porównania wartości parametrów pożarowych wyznaczonych przy pomocy tego programu z parametrami, które uzyskano w symulatorze wspomagania dowodzenia.
EN
The article presents description of smoke and fire visualization in simulator intended for training leadership during rescue operations of multi-storey buildings. The fire took place in a hotel room. There were prepared two cases according to configuration of ventilation. In the first case, the room exit doors were closed. In the second case, the same doors were opened. There was conducted modeling of similar fire in Fire Dynamics Simulator. Then the fire parameters appointed by FDS were compared and displayed by training leadership simulator.
PL
W prezentowanej pracy został omówiony problem dotyczący modelowania pożarów i rozprzestrzenia się dymu w obiektach przemysłowych i użyteczności publicznej. Modele opisujące proces spalania wykorzystują równania bilansu pędu, energii i masy. Do rozwiązania tych równań zastosowano program ANSYS FLUENT. Wyniki uzyskane z numerycznej symulacji pożaru są pomocne w ocenie prawidłowego działania urządzeń wentylacji pożarowej oraz bezpieczeństwa osób przebywających w strefie pożaru.
EN
The problem of modeling fire and smoke spread in industrial and public buildings is discussed in the paper. Models describing the combustion process are based on the momentum, energy and mass balance equations. To solve these equations the program ANSYS FLUENT was applied. The results obtained in fire numerical simulations can be helpful in evaluating the proper operation of ventilation equipment and fire safety of persons residing in a fire zone.
EN
Introduction: The introduction to this paper deals with the question of defining fire-prevention distances for constructions in a modern energy enterprise operating on alternative energy sources, which can also simultaneously produce gas, electricity and heat from agricultural waste. The purpose, object and subject of the research are defined, and the basic methods used during the scientific work are presented. The analysis of the process of biogas production technology, which includes the indication of the most dangerous technological structure in the biogas production complex also involves an analysis of the existing means of fire protection, including the main technological equipment. Methods: The first part of the article gives a general description of the object, its constructive elements and scenarios of the emergence of a hazardous situation, which can lead to a fire or explosion in the fermenters. The effect of the size of the hole through which the gas flows and burns on the diameter of the flame and its temperature, creating a hazard for adjacent structures, was investigated. The results of calculations of the excess pressure of the explosion of biogas in the fermenter, which can occur as a result of an emergency situation, are demonstrated. The integrity of the fermenter elements was determined in the conditions of an excess explosion pressure, and the effect of the excess explosion pressure on the calculation of safe distances was demonstrated. The main part of the article defines the type of deformation in the main structural elements of the most dangerous structure in the complex (complete or partial destruction or damage) and, to a reasonable extent, the consequences to which this destruction can lead. The effect of the size of the hole through which the gas flows and burns on the diameter of the flame and its temperature, which creates a hazard for adjacent structures, was investigated. Using the “FlowVision 2.5” software packages and “MathCaD” software suites, the schemes of impact of the main forces on the elements of the fermenter’s biogas plants and the graphical models of the development of combustion in the fermenter during a possible fire, including the initial stage of burning and the fire climax, are presented. Based on the results of calculations for the scenario of the most dangerous accident, the maximum possible values of the height and radius of the flame, the cross-sectional area of the flame and the flame temperature are determined. The algorithm for calculating the safe distances between fermenters for the production of biogas is given. A justification for the minimum fire distances between the fermenters for the safe operation of the biogas production is given. Results and conclusions: The final part contains the main results of the research, in particular, of the actual scientific and practical task of ensuring explosion safety in biogas production. Furthermore, the method of estimating the safe distances between the fermenters for biogas production is substantiated. Conclusions on the results of scientific work are presented and a list of literary sources used by the authors is indicated.
PL
Wprowadzenie: We wprowadzeniu do artykułu zawarto opis kwestii ustalenia przeciwpożarowych odstępów dla urządzeń współczesnego przedsiębiorstwa energetycznego, funkcjonującego na alternatywnych źródłach energii, a także jednocześnie produkującego gaz, elektryczność i ciepło drogą przetwarzania odpadów gospodarstwa rolnego. Określono cel, obiekt i przedmiot badań, a także przytoczono główne metody wykorzystane w czasie prowadzenia pracy naukowej. Przytoczono analizę procesu technologii produkcji biogazu, uwzględniającą ustalenie najbardziej niebezpiecznego technicznego urządzenia kompleksu do produkcji biogazu. Metody: W pierwszej części artykułu przytoczono ogólny opis obiektu, jego elementów konstrukcyjnych oraz scenariusze zaistnienia niebezpiecznej sytuacji, które mogą doprowadzić do pożaru lub wybuchu w komorze fermentacyjnej. Przytoczono rezultaty wyliczeń nadmiernego ciśnienia wybuchu biogazu w fermentatorze, które mogą pojawić się w rezultacie sytuacji awaryjnej. Określono całość elementów fermentatora pod działaniem nadmiernego ciśnienia wybuchu. Ustalono, że obliczeniowe nadmierne ciśnienie wybuchu nie wpływa na określenie bezpiecznych odstępów przeciwpożarowych między fermentatorami. W głównej części artykułu określono typ deformacji dla głównych elementów konstrukcji najbardziej niebezpiecznego urządzenia kompleksu (całkowite zniszczenie lub częściowe uszkodzenie). Zbadano wpływ rozmiaru otworu, przez który wypływa i płonie gaz, na średnicę pochodni i temperaturę płomienia, stwarzającego niebezpieczeństwo dla urządzeń sąsiednich. Przy pomocy kompleksów programowych „FlowVision 2.5” i „MathCaD” opracowano i przytoczono schematy wpływu sił mechanicznych na elementy konstrukcji fermentatora do produkcji biogazu, a także przytoczono graficzne modele rozwoju palenia się fermentatora w czasie możliwego pożaru, włączającego początkowy etap palenia się i kulminacyjny moment pożaru. Na podstawie rezultatów wyliczeń według scenariusza najniebezpieczniejszej awarii obliczono najbardziej prawdopodobną wartość pola przekroju pochodni i temperatury płomienia i przytoczono algorytm wyliczeń dla określenia bezpiecznych odległości miedzy fermentatorami. Uzasadniono minimalną wartość odstępów przeciwpożarowych między fermentatorami dla bezpiecznej eksploatacji kompleksu do produkcji biogazu. Wyniki i wnioski: W części końcowej przytoczono główne rezultaty badań, przede wszystkim rozwiązano aktualne naukowo-praktyczne zadanie zapewnienia bezpieczeństwa pożarowego i wybuchowego dla produkcji biogazu, a także uzasadniono metodykę szacunkowej oceny bezpiecznego odstępu między fermentatorami do produkcji biogazu. Przytoczono wnioski z rezultatów pracy naukowej i listę wykorzystanych przez autorów źródeł literatury.
EN
Risks of fire occurrence in underground mines are known for a long time. Evacuation and rescue plans allow to each underground mine to respond and establish control in case of emergency. The primary goal of this paper is to determine the optimal system for evacuation in case of fire in underground mines and through a process of computer simulation to be presented to all workers that are affected by this issue. In this study is developed a system that allows by using available software to work out the complete evacuation plans that include analysis of fire scenarios and optimal routes for evacuation. With development of database of fire scenarios, it is possible to plan routes for evacuation in all situations. This presented methodology can serve to make effective system for evacuation and rescue in case of fire and to help save lives and protect the financial investment in the mine. This methodology represents the most economical option of making an effective system for evacuation and also can serve as an idea of making a software package that includes all the steps of making a system for evacuation and rescue in case of fire in underground mines. This presented model will have increased accuracy compared to other models presented so far, because of the prepared 3D model of the underground mine which includes the actual dimensions of the mine along with its associated elements from which the fire dynamics and system for evacuation depends.
9
Content available remote Badania zapalności do oceny rozwoju pożaru
58%
PL
Przy ocenie właściwości ogniowych podstawowe znaczenie ma określenie, w jakich warunkach i jak szybko dany materiał się zapali. Jest to niezbędne w analizie, który materiał zapali się najpierw, a także do określenia rozwoju pożaru w pomieszczeniu na skutek „zdalnego” zapalenia lub na skutek rozprzestrzeniania płomienia po powierzchni. Zdolność do zapalenia jest charakteryzowana przez właściwości materiału, które mogą być obliczone z danych z badań małej skali. Te obliczone właściwości służą do przewidywania zapalenia w rzeczywistych warunkach pożaru (przy założeniu, że są one znane lub określone w komputerowych modelach rozwoju pożaru). Do określenia zapalności służą metody badawcze, w których ekspozycja cieplna może być typu radiacyjnego, konwekcyjnego lub przy działaniu płomienia. W artykule przedstawiono metody i wyniki badań wg ISO 11925-3 w przypadku źródła zapalenia A-H.
EN
At the evaluation of fire properties of given material the primary importance has determining in what conditions and as quickly will ignite. It is valid for determining, which material will ignite at first as well as for determining the development of the fire in the room do to "remote" inflammations or as a result of spread the flame by the area. The ignitability in the fire is characteristic by properties of the material and can be calculated from data from examinations in small scale. These calculated properties are used to predict ignition in real fire (at the assumption that they are known or determined in computer models of the development of the fire). For the ignitability determination research methods, in which the thermal exposure can be radiation, convection type or acting of the flame. At the work testing methods according to ISO 11925-3 of the source A-H and results of testing were presented.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.