Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  mocowanie protezy
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Purpose: The application of single implant-retained dentures (SIDs) is still rare. It seems that the reason of that is the fear of the overloading of a bone tissue around the implant that alone bears the occlusal loads. In this paper, stress level in the bone tissue around the single mini-implant that alone retained the lower denture was investigated. This stress level depends on the denture joint (the attachment) to the implant. Design/methodology/approach: 3D finite element method (FEM) analysis was used in order to determine the transmission of occlusal loads between mucous membrane foundation and the bone tissue around small diameter (1.8 mm) implant. Standard rotationally and axially mobile denture attachments were compared with the laterally compliant silicone attachment. Oblique mastication loads were assumed for the purposes of a better simulation of realistic conditions. Findings: Both types of standard attachments, rotationally and axially mobile, born remarkable values of oblique mastication force. This load results in a high stress in the bone tissue around a single mini-implant, in the area convergent with clinically observed “funnel-shaped” marginal bone loss around the implant neck. The silicone attachment reduced the loading to a level, which did not create any stress that would be dangerous for the bone tissue. Research limitations/implications: In the FEM model a perfect denture adherence to mucous foundation was assumed and a perfect joint between the implant and bone tissue. Further simplification were the linear isotropic characteristics of used materials. Practical implications: The use of single mini-implants requires the highest quality of the alloy and surface finishing due to the risk of fatigue cracks in case of a quickly progressing “funnel-shaped” bone loss. The silicone attachment provided better utilization of the mucous membrane support that significantly improves safety of implant and diminishes the requirements of bone foundation conditions for an implantological treatment. Originality/value: Presented was a possibility to achieve a much more reliable SID by means of used silicone attachment.
2
84%
EN
Purpose: The aim of this study is to foreseen the influence of elastomers on the development of mucous-borne dentures in the aspect of bio-compatible use of prosthetic foundation tissue load bearing capacity. Design/methodology/approach: Multi-criteria comparative analysis based on the dendrological matrix of attractiveness and potential was used for the studies of denture solution and materials. There were differentiated seven groups of conventional dentures without an implantological stabilisation - the so-called hard dentures (CD) and those with a soft relining (CD-P), stabilized on one implant (SID) or on two implants (TID), that were differentiated as far as the denture attachment to implant was concerned. The first group was marked as "hard" (K) due to the used materials and inconsiderable lateral compliance. The elastomeric attachments (S) constituted the second group of attachments. Findings: In case of conventional dentures a significant influence of the relining on attractiveness was observed. In case of dentures retained on elastomeric attachments - they decided not only on the attractiveness, but they have also significantly increased dentures' potential. Research limitations/implications: Throughout the studies the variation of denture bearing structure materials were not taken into account, based on the assumption that acrylates are the most commonly used. Practical implications: The similar level of attractiveness of dentures retained on implants significantly varying as far as their construction is concerned shows that the focus should be mainly put on material design of elastomers' wearing characteristics. Originality/value: Multi-criteria heuristic analysis proved to be an effective tool for examination of dentures in the aspect evaluation of dentures material and cosntruction that show perspectives of the broadest use due to exploitation of the tissue bearing capability.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.